Direkt zum Inhalt
Merck

76884

Supelco

Anthranilamid

matrix substance for MALDI-MS, ≥99.0% (HPLC)

Synonym(e):

2-AB, 2-Amino-benzamid, Anthranilsäure-amid

Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise


About This Item

Lineare Formel:
2-(H2N)C6H4CONH2
CAS-Nummer:
Molekulargewicht:
136.15
Beilstein:
508509
EG-Nummer:
MDL-Nummer:
UNSPSC-Code:
12000000
PubChem Substanz-ID:
NACRES:
NA.21

Qualität

matrix substance for MALDI-MS

Qualitätsniveau

Assay

≥99% (NT)
≥99.0% (HPLC)

Form

crystals

Methode(n)

MALDI-MS: suitable

mp (Schmelzpunkt)

111-113 °C (lit.)

Kationenspuren

Ba: ≤5 mg/kg
Ca: ≤5 mg/kg
Cd: ≤5 mg/kg
Co: ≤5 mg/kg
Cr: ≤5 mg/kg
Cu: ≤5 mg/kg
Fe: ≤30 mg/kg
K: ≤50 mg/kg
Mg: ≤5 mg/kg
Mn: ≤5 mg/kg
Na: ≤150 mg/kg
Ni: ≤5 mg/kg
Pb: ≤5 mg/kg
Zn: ≤5 mg/kg

SMILES String

NC(=O)c1ccccc1N

InChI

1S/C7H8N2O/c8-6-4-2-1-3-5(6)7(9)10/h1-4H,8H2,(H2,9,10)

InChIKey

PXBFMLJZNCDSMP-UHFFFAOYSA-N

Suchen Sie nach ähnlichen Produkten? Aufrufen Leitfaden zum Produktvergleich

Anwendung

Verwendet für nicht-selektive, wirksame Fluoreszenzmarkierung von Glycanen Leicht weniger empfindlich als Anthranilsäure (2-AA) für die Glycanmarkierung.

Hinweis zur Analyse

Die Metallspuren-Analyse mit ICP entspricht den Anforderungen.

Ähnliches Produkt

Produkt-Nr.
Beschreibung
Preisangaben

Piktogramme

Exclamation mark

Signalwort

Warning

H-Sätze

Gefahreneinstufungen

Eye Irrit. 2

Lagerklassenschlüssel

11 - Combustible Solids

WGK

WGK 1

Flammpunkt (°F)

>365.0 °F

Flammpunkt (°C)

> 185 °C


Hier finden Sie alle aktuellen Versionen:

Analysenzertifikate (COA)

Lot/Batch Number

Die passende Version wird nicht angezeigt?

Wenn Sie eine bestimmte Version benötigen, können Sie anhand der Lot- oder Chargennummer nach einem spezifischen Zertifikat suchen.

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

Kunden haben sich ebenfalls angesehen

Yan Cai et al.
The Analyst, 138(21), 6270-6276 (2013-09-07)
Analysis of oligosaccharides by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) is often limited by their low ionization efficiency and inadequate fragmentation information. Derivatizations of oligosaccharides to enhance their ionization in MS are widely used, but most of these
Antonio da Silva et al.
Leukemia & lymphoma, 55(7), 1609-1617 (2013-09-13)
Biosimilar development involves a target-directed iterative process to ensure a similar product to the originator. Here we report the preclinical development of the proposed biosimilar rituximab (GP2013). Post-translational modifications and bioactivities of GP2013 versus originator rituximab were engineered and monitored
Nicholas T Ventham et al.
PloS one, 10(4), e0123028-e0123028 (2015-04-02)
Serum N-glycans have been identified as putative biomarkers for numerous diseases. The impact of different serum sample tubes and processing methods on N-glycan analysis has received relatively little attention. This study aimed to determine the effect of different sample tubes
Meritxell Balmaña et al.
Clinica chimica acta; international journal of clinical chemistry, 442, 56-62 (2015-01-18)
Pancreatic adenocarcinoma (PDAC) usually shows an enhanced expression of sialyl-Lewis X (sLe(x)) and related epitopes. PDAC may secrete some of the proteins carrying such increased sLe(x) determinant into serum, so they could be used as PDAC markers. Previously, we identified
Lei Zhu et al.
mAbs, 6(6), 1474-1485 (2014-12-09)
CTLA4-Ig is a highly glycosylated therapeutic fusion protein that contains multiple N- and O-glycosylation sites. Glycosylation plays a vital role in protein solubility, stability, serum half-life, activity, and immunogenicity. For a CTLA4-Ig biosimilar development program, comparative analytical data, especially the

Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..