  • Evaluation of the effect of different sampling time periods and ambient air pollutant concentrations on the performance of the Radiello diffusive sampler for the analysis of VOCs by TD-GC/MS.

Evaluation of the effect of different sampling time periods and ambient air pollutant concentrations on the performance of the Radiello diffusive sampler for the analysis of VOCs by TD-GC/MS.

Journal of environmental monitoring : JEM (2011-08-11)
E Gallego, F J Roca, J F Perales, X Guardino
要旨

The effect of different sampling exposure times and ambient air pollutant concentrations on the performance of Radiello® samplers for analysis of volatile organic compounds (VOCs) is evaluated. Quadruplicate samples of Radiello® passive tubes were taken for 3, 4, 7 and 14 days. Samples were taken indoors during February and March 2010 and outdoors during July 2010 in La Canonja (Tarragona, Spain). The analysis was performed by automatic thermal desorption (ATD) coupled with capillary gas chromatography (GC)/mass spectrometry detection (MS). The results show significant differences (t-test, p < 0.05) between the amounts of VOCs obtained from the sum of two short sampling periods and a single equivalent longer sampling period for 65% of all the data. 17% of the results show significantly larger amounts of pollutant in the sum of two short sampling periods. Back diffusion due to changes in concentrations together with saturation and competitive effects between the compounds during longer sampling periods could be responsible for these differences. The other 48% of the results that are different show significantly larger amounts in the single equivalent longer sampling period. The remaining 35% of the results do not show significant differences. Although significant differences are observed in the amount of several VOCs collected over two shorter sampling intervals compared to the amount collected during a single equivalent longer sampling period, the ratios obtained are very close to unity (between 0.7 and 1.2 in 75% of cases). We conclude that Radiello® passive samplers are useful tools if their limitations are taken into account and the manufacturer's recommendations are followed.

材料
製品番号
ブランド
製品内容

radiello カートリッジ吸収剤, for sampling BTEX and VOCs (CS2 Desorption), matrix SS net (100 mesh, 5.8 mm diam.), activated with activated charcoal (30-50 mesh), pk of 20
radiello Triangular Support Plate, pk of 20
radiello 拡散ボディー, white, configured for general use, pk of 20
radiello カートリッジ吸収剤, for sampling Aldehydes, matrix SS net with 2,4-DNPH coated FLORISIL®, pk of 20
radiello カートリッジ吸収剤, for sampling Ammonia (NH3), matrix microporous PE impregnated with phosphoric acid, pk of 20
radiello 拡散ボディー, blue, configured for sampling light sensitive compounds, pk of 20
radiello 拡散ボディー, yellow, configured for reduced sampling rates, pk of 20
radiello カートリッジ吸収剤, for sampling BTEX and VOCs (thermal desorption), matrix SS net (3 x 8 μm, 4.8 mm diam.), Carbograph, pk of 20
Supelco
radiello Methylene Blue Calibration Standard for H2S (Hydrogen Sulfide), pkg of 100 mL
radiello Outdoor Shelter, pk of 10
radiello Barcode Labels, pk of 198
radiello Vertical Adapter, threaded for standard use, pk of 20
radiello BTEX/VOCスターターキット、CS2脱離
radiello Filtration Kit, pk of 20
radiello BTEX/VOCスターターキット、熱脱離
Supelco
radiello BTEX Calibration Kit (Thermal Desorption)
radiello スターターキット
radiello On-Field Thermometer(フィールド用温度計), Includes one standard Radiello vertical adapter (RAD122) for each thermometer, configured for standard use, pk of 3
radiello麻酔ガス・蒸気サンプラー
radiello Empty Storage Tubes, glass (with stopper), volume 2.8 mL, pk of 100
radiello カートリッジ吸収剤, for sampling Anaesthetic Gases/Vapors, matrix SS net with mix of mol sieve and activated charcoal (30-50 mesh), pk of 20
radiello Empty Storage Tubes, polypropylene (with stopper), volume 12 mL, pk of 100
Supelco
radiello BTEX Calibration Kit (CS2 Desorption)
radiello Clips, suspending Radiello triangular support plate, pk of 20
radiello 1,3-ブタジエンスターターキット、昇温脱離, pkg of 1 kit (2 RAD141 adsorbing cartridges and barcode labels, 1 RAD1202 yellow diffusive body, 1 RAD121 triangular support plate, 1 instruction sheet)
radiello 拡散ボディー, permeative, configured for anaesthetic gases and vapors, pk of 20
radiello On-Field Thermometer(フィールド用温度計), Reader, pk of 1
radiello Replacement Mounting Strips, for use with Radiello Outdoor Shelter, pk of 100