コンテンツへスキップ
Merck
  • Feasibility of halogen determination in noncombustible inorganic matrices by ion chromatography after a novel volatilization method using microwave-induced combustion.

Feasibility of halogen determination in noncombustible inorganic matrices by ion chromatography after a novel volatilization method using microwave-induced combustion.

Talanta (2015-11-26)
Rodrigo M Pereira, Vanize C Costa, Carla A Hartwig, Rochele S Picoloto, Erico M M Flores, Fabio A Duarte, Marcia F Mesko
要旨

A microwave-induced combustion (MIC) system based on the volatilization process was applied for subsequent halogen determination from noncombustible inorganic matrices. Portland cement samples were selected to demonstrate the feasibility of the proposed method, allowing the subsequent determination of Cl and F by ion chromatography (IC). Samples were mixed with high-purity microcrystalline cellulose, wrapped with a polyethylene film and combusted in quartz closed vessels pressurized with oxygen (20bar). Water and NH4OH (10, 25 or 50m mol L(-1)) were evaluated for Cl and F absorption, but water was selected, using 5min of reflux after volatilization. Final solutions were also suitable for analysis by pontentiometry with ion-selective electrode (ISE) for both analytes, and no difference was found when comparing the results with IC. The accuracy of the proposed method for Cl was evaluated by analysis of certified reference materials (CRMs), and agreement with certified values ranged from 98% to 103%. Results were also compared to those using the procedure recommended by the American Society of Testing and Materials (ASTM) for the determination of total chlorides (C114-13), and no difference was found. Volatilization by MIC using a mixture of cement, cellulose and a biological CRM was carried out in order to evaluate the accuracy for F, and recovery was about 96%. The proposed method allowed suitable limits of detection for Cl and F by IC (99 and 18mg kg(-1), respectively) for routine analysis of cement. Using the proposed method, a relatively low standard deviation (<7%), high throughput (up to eight samples can be processed in less than 30min) and lower generation of laboratory effluents, when compared to the ASTM method, were obtained. Therefore, the method for volatilization of Cl and F by MIC and subsequent determination by IC can be proposed as a suitable alternative for cement analysis.

材料
製品番号
ブランド
製品内容

Sigma-Aldrich
酢酸, glacial, ACS reagent, ≥99.7%
Sigma-Aldrich
硝酸, ACS reagent, 70%
Sigma-Aldrich
酢酸, glacial, ReagentPlus®, ≥99%
Sigma-Aldrich
重炭酸ナトリウム, ACS reagent, ≥99.7%
Sigma-Aldrich
炭酸ナトリウム, powder, ≥99.5%, ACS reagent
Sigma-Aldrich
重炭酸ナトリウム, powder, BioReagent, for molecular biology, suitable for cell culture, suitable for insect cell culture
Sigma-Aldrich
酢酸アンモニウム, ACS reagent, ≥97%
Sigma-Aldrich
炭酸ナトリウム, ACS reagent, anhydrous, ≥99.5%, powder or granules
Sigma-Aldrich
ヨウ化水素酸, 57 wt. % in H2O, distilled, stabilized, 99.95%
Sigma-Aldrich
フッ化ナトリウム, ACS reagent, ≥99%
Sigma-Aldrich
重炭酸ナトリウム, ReagentPlus®, ≥99.5%, powder
Sigma-Aldrich
硝酸, 70%, purified by redistillation, ≥99.999% trace metals basis
Sigma-Aldrich
塩化ナトリウム, for molecular biology, DNase, RNase, and protease, none detected, ≥99% (titration)
Sigma-Aldrich
酢酸アンモニウム, ≥99.99% trace metals basis
Sigma-Aldrich
酢酸, glacial, ≥99.99% trace metals basis
Sigma-Aldrich
硝酸アンモニウム, ≥99.0%
Sigma-Aldrich
酢酸, glacial, puriss., meets analytical specification of Ph. Eur., BP, USP, FCC, 99.8-100.5%
Sigma-Aldrich
塩化ナトリウム 溶液, 0.9% in water, BioXtra, suitable for cell culture
Sigma-Aldrich
酢酸 溶液, suitable for HPLC
Sigma-Aldrich
塩化ナトリウム, BioReagent, suitable for cell culture, suitable for insect cell culture, suitable for plant cell culture, ≥99%
Sigma-Aldrich
塩化ナトリウム 溶液, 5 M in H2O, BioReagent, for molecular biology, suitable for cell culture
Sigma-Aldrich
硝酸, puriss. p.a., 65.0-67.0%
Sigma-Aldrich
硝酸アンモニウム, ACS reagent, ≥98%
Sigma-Aldrich
炭酸ナトリウム, ACS reagent (primary standard), anhydrous, 99.95-100.05% dry basis
Sigma-Aldrich
重炭酸ナトリウム, anhydrous, free-flowing, Redi-Dri, ACS reagent, ≥99.7%