コンテンツへスキップ
Merck
  • Ultra-high performance liquid chromatography-quadrupole time-of-flight mass spectrometry to identify contaminants in water: an insight on environmental forensics.

Ultra-high performance liquid chromatography-quadrupole time-of-flight mass spectrometry to identify contaminants in water: an insight on environmental forensics.

Journal of chromatography. A (2014-05-06)
Ana Masiá, Julian Campo, Cristina Blasco, Yolanda Picó
要旨

Ultra-high pressure liquid chromatography-quadrupole time-of-flight mass spectrometry (UHPLC-QqTOF-MS) acquiring full scan MS data for quantification, and automatic data dependent information product ion spectra (IDA-MS/MS) without any predefinition of the ions by the user was checked for identifying organic contaminants in water samples. The use of a database with more than 2000 compounds achieved high confidence results for a wide number of contaminants based upon retention time, accurate mass, isotopic pattern and MS/MS library searching. More than 20 contaminants, mostly pharmaceuticals, but also mycotoxins and polyphenols were unambiguously identified. Furthermore, the combination of statistical data analysis using principal component analysis (PCA) followed by empirical formula calculation, on-line database searching and MS/MS fragment ion interpretation achieves not only the successful detection of unknown contaminants but also the selection of those relevant to different types of waters. Unknown compounds, such as C₂₀H₃₄O₃, were identified in waste water showing the prospects of this technique. A group of 42 currently used pesticides were selected as target compounds to evaluate the quantitative possibilities. Mean recoveries and percentage relative standard deviation (RSD) were 48-79% (4-20% RSD). The limit of detections ranged from 0.02 to 2 ng L(-1), with a validated limit of quantification of 2 ng L(-1) for water after solid-phase (SPE) isolation and concentration. The quantitative data obtained using UHPLC-QqTOF-MS were compared with those obtained using conventional LC-MS/MS with a triple quadrupole (QqQ).

材料
製品番号
ブランド
製品内容

Sigma-Aldrich
メタノール, suitable for HPLC, ≥99.9%
Sigma-Aldrich
ジクロロメタン, suitable for HPLC, ≥99.8%, contains amylene as stabilizer
Sigma-Aldrich
メタノール, ACS reagent, ≥99.8%
Sigma-Aldrich
ジクロロメタン, contains 40-150 ppm amylene as stabilizer, ACS reagent, ≥99.5%
Sigma-Aldrich
メタノール, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
メタノール, HPLC Plus, ≥99.9%
Sigma-Aldrich
ジクロロメタン, HPLC Plus, for HPLC, GC, and residue analysis, ≥99.9%, contains 50-150 ppm amylene as stabilizer
Sigma-Aldrich
ギ酸アンモニウム, reagent grade, 97%
Sigma-Aldrich
メタノール, suitable for HPLC, gradient grade, suitable as ACS-grade LC reagent, ≥99.9%
Sigma-Aldrich
メタノール, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.8% (GC)
Sigma-Aldrich
ジクロロメタン, puriss. p.a., ACS reagent, reag. ISO, ≥99.9% (GC)
Sigma-Aldrich
ジクロロメタン, ACS reagent, ≥99.5%, contains 40-150 ppm amylene as stabilizer
Sigma-Aldrich
メタノール, Laboratory Reagent, ≥99.6%
Sigma-Aldrich
ギ酸アンモニウム, ≥99.995% trace metals basis
Sigma-Aldrich
メタノール, ACS spectrophotometric grade, ≥99.9%
Sigma-Aldrich
ギ酸アンモニウム 溶液, BioUltra, 10 M in H2O
Sigma-Aldrich
メタノール, ACS reagent, ≥99.8%
Sigma-Aldrich
メタノール, BioReagent, ≥99.93%
Sigma-Aldrich
メタノール, Absolute - Acetone free
Sigma-Aldrich
メタノール, JIS special grade, ≥99.8%
USP
メチルアルコール, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
ジクロロメタン, puriss., meets analytical specification of Ph. Eur., NF, ≥99% (GC)
Sigma-Aldrich
ジクロロメタン, ACS reagent, ≥99.5%, contains 40-150 ppm amylene as stabilizer
Sigma-Aldrich
ジクロロメタン, anhydrous, ≥99.8%, contains 40-150 ppm amylene as stabilizer
Sigma-Aldrich
メタノール, ACS reagent, ≥99.8%
Sigma-Aldrich
メタノール, SAJ first grade, ≥99.5%
Sigma-Aldrich
メタノール, anhydrous, 99.8%
Supelco
ジクロロメタン, Pharmaceutical Secondary Standard; Certified Reference Material
Supelco
ギ酸アンモニウム 溶液, 10 mM in H2O, suitable for HPLC
Supelco
ギ酸アンモニウム, eluent additive for LC-MS, LiChropur, ≥99.0%