コンテンツへスキップ
Merck
  • Polymer monolith microextraction using poly(butyl methacrylate-co-1,6-hexanediol ethoxylate diacrylate) monolithic sorbent for determination of phenylurea herbicides in water samples.

Polymer monolith microextraction using poly(butyl methacrylate-co-1,6-hexanediol ethoxylate diacrylate) monolithic sorbent for determination of phenylurea herbicides in water samples.

Talanta (2015-11-26)
Shu-Ling Lin, Yu-Ru Wu, Ming-Ren Fuh
要旨

In this study, recently developed 1,6-hexanediol ethoxylate diacrylate (HEDA)-based polymeric monoliths were utilized as sorbents for efficient extraction of phenylurea herbicides (PUHs) from water samples. The HEDA-based monolithic sorbents were prepared in a fused silica capillary (0.7mm i.d., 4.5-cm long) for polymer monolith microextraction (PMME). The experimental parameters of PMME microextraction including sample loading speed, pH of sample solution, composition of elution solvent, and addition of salt were optimized to efficiently extract PUHs from environmental water samples. The extracted PUHs were determined using ultra-high performance liquid chromatography (UHPLC) with UV-photodiode array detection. The extraction recoveries for PUHs-spiked water samples were 91.1-108.1% with relative standard deviations lower than 5%. The linearity range was 0.025-25ngmL(-1) for each PUH and the detection limits of PUHs were estimated at 0.006-0.019ng mL(-1). In addition, good intra-day/inter-day precision (0.1-8.7%/0.2-8.9%) and accuracy (92.0-108.0%/96.5-105.2%) of the proposed method were obtained. The extraction capacity of the monolith-filled capillary was also determined to be approximately 1μg. Moreover, each monolith-filled capillary could be reused up to 8 times without carry-over. According to the European Union regulations, the allowed permissible limit of any single herbicide in drinking water is 0.1ng mL(-1). This permissible level fell in the linear range examined in this study. In addition, the proposed method provided detection limits lower than the allowed permissible level, which demonstrated the feasibility of utilizing the HEDA-based monolithic sorbent to perform PMME for determining contaminants, such as PUHs, in environmental application.

材料
製品番号
ブランド
製品内容

Sigma-Aldrich
メタノール, ACS reagent, ≥99.8%
Sigma-Aldrich
水酸化ナトリウム, ACS reagent, ≥97.0%, pellets
Sigma-Aldrich
水酸化ナトリウム, reagent grade, ≥98%, pellets (anhydrous)
Sigma-Aldrich
水酸化ナトリウム 溶液, 50% in H2O
Sigma-Aldrich
アセトニトリル, ACS reagent, ≥99.5%
Sigma-Aldrich
アセトニトリル, anhydrous, 99.8%
Sigma-Aldrich
水酸化ナトリウム 溶液, BioUltra, for molecular biology, 10 M in H2O
Sigma-Aldrich
水酸化ナトリウム 溶液, 1.0 N, BioReagent, suitable for cell culture
Sigma-Aldrich
1-プロパノール, ACS reagent, ≥99.5%
Sigma-Aldrich
水酸化ナトリウム, BioXtra, ≥98% (acidimetric), pellets (anhydrous)
Sigma-Aldrich
メタノール, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.8% (GC)
Sigma-Aldrich
水酸化ナトリウム, puriss. p.a., ACS reagent, reag. Ph. Eur., K ≤0.02%, ≥98%, pellets
Sigma-Aldrich
水酸化ナトリウム, reagent grade, 97%, powder
Sigma-Aldrich
水酸化ナトリウム, puriss., meets analytical specification of Ph. Eur., BP, NF, E524, 98-100.5%, pellets
Sigma-Aldrich
メタノール, Laboratory Reagent, ≥99.6%
Sigma-Aldrich
メタノール, anhydrous, 99.8%
Sigma-Aldrich
水酸化ナトリウム, pellets, semiconductor grade, 99.99% trace metals basis
Sigma-Aldrich
メタノール, Absolute - Acetone free
Sigma-Aldrich
メタノール, BioReagent, ≥99.93%
Sigma-Aldrich
水酸化ナトリウム 溶液, 5.0 M
Sigma-Aldrich
メタノール, ACS spectrophotometric grade, ≥99.9%
Supelco
SPMEファイバーアセンブリー ジビニルベンゼン/カルボキセン/ポリジメチルシロキサン (DVB/CAR/PDMS), needle size 24 ga, for use with manual holder
Sigma-Aldrich
水酸化ナトリウム 溶液, 0.1 M
Supelco
SPMEファイバーアセンブリー ジビニルベンゼン/カルボキセン/ポリジメチルシロキサン (DVB/CAR/PDMS), needle size 24 ga, StableFlex
Supelco
SPMEファイバーアセンブリー ジビニルベンゼン/カルボキセン/ポリジメチルシロキサン (DVB/CAR/PDMS), needle size 23 ga, StableFlex, for use with autosampler
Sigma-Aldrich
水酸化ナトリウム, puriss. p.a., ACS reagent, K ≤0.02%, ≥98.0% (T), pellets
Sigma-Aldrich
メタノール, ACS reagent, ≥99.8%
Sigma-Aldrich
メタクリル酸ラウリル, contains 500 ppm MEHQ as inhibitor, 96%
Supelco
SPMEファイバーアセンブリー ジビニルベンゼン/カルボキセン/ポリジメチルシロキサン (DVB/CAR/PDMS), needle size 23 ga, StableFlex, for use with manual holder or autosampler, fiber L 2 cm
Sigma-Aldrich
メタノール, JIS special grade, ≥99.8%