The low or no protein recovery issue may be attributed to over-concentration of the protein, leading to precipitation. The User Guide provides guidance on maximizing sample recovery: Low sample recovery in the concentrate may be due to adsorptive losses, over-concentration, or passage of sample through the membrane. Adsorptive losses depend upon solute concentration, its hydrophobic nature, temperature and time of contact with filter device surfaces, sample composition, and pH. To minimize losses, remove concentrated samples immediately after centrifugal spin. If the starting sample concentration is high, monitor the centrifugation process in order to avoid over-concentration of the sample. Over-concentration can lead to precipitation and potential sample loss. If the sample appears to be passing through the membrane, choose a lower MWCO Amicon device.
おすすめの製品
物質
polyethylene cap
polyethylene liner
polypropylene tube
regenerated cellulose membrane
regenerated cellulose support
styrene-butadiene housing
品質水準
無菌性
non-sterile
製品種目
Amicon®
包装
pkg of 24 pkg
pkg of 8 pkg
pkg of 96 pkg
メーカー/製品名
Amicon® Ultra
sustainability
Greener Alternative Product
パラメーター
4 mL sample volume
テクニック
protein extraction: suitable
protein purification: suitable
L
124 mm (4.88 in.)
直径
17.3 mm
ろ過面積
3 cm2
容量
4 mL
有効容積
≤4 mL
4 mL
ポアサイズ
3 kDa MWCO
環境により配慮した代替製品カテゴリ
輸送温度
ambient
詳細
アプリケーション
- Ultrafiltration with 3,000 Dalton molecular weight cutoff Ultracel® membrane.
- Concentration of biological samples containing antigens, antibodies, enzymes, nucleic acids, or microorganisms.
- Purification of macromolecular components found in tissue culture extracts or cell lysates and protein removal prior to HPLC.
- Concentration of dilute or pre-purified proteins from column eluents.
- Desalting, buffer exchange and protein dialysis.
- Size exclusion and protein fractionation.
特徴および利点
物理的形状
法的情報
試験成績書(COA)
製品のロット番号・バッチ番号を入力して、試験成績書(COA) を検索できます。ロット番号・バッチ番号は、製品ラベルに「Lot」または「Batch」に続いて記載されています。
この製品を見ている人はこちらもチェック
資料
Filtration methods and membrane filter selection in nanoparticle purification and production.
ナノ粒子の精製と製造における、ろ過法とメンブレンフィルターの選定。
Explore ultrafiltration membrane principles and benefits for protein sample preparation, including solvent exchange and sample concentration.
溶媒交換やサンプル濃縮などのタンパク質サンプル調製のための限外ろ過膜の原理と利点をご覧ください。
プロトコル
ヒト血漿プロテオームは、バイオマーカーの発見と検討を行うための豊富な資源です。
The human plasma proteome is a vast resource for biomarker discovery and investigation.
-
What could be the reason for no protein recovery (in the concentrate or flow through) while using the UFC800324 to purify protein? Could the protein may be absorbed in the filter?
1 回答-
役に立ちましたか?
-
-
What is max g force these filters can take? i.e. what sort of rpm or g force should I spin at?
1 回答-
The UFC8003 protocol states to spin at 7,500 × g maximum for approximately 10–40 minutes. See the image below for further details.
役に立ちましたか?
-
-
Can we centrifuge these tubes in a normal 15 mL swinging bucket centrifuge?
1 回答-
Yes, the device can be used in centrifuges with a swinging bucket or fixed-angle rotor.
役に立ちましたか?
-
アクティブなフィルタ
ライフサイエンス、有機合成、材料科学、クロマトグラフィー、分析など、あらゆる分野の研究に経験のあるメンバーがおります。.
製品に関するお問い合わせはこちら(テクニカルサービス)