Passa al contenuto
Merck

Antifeedants Produced by Bacteria Associated with the Gut of the Pine Weevil Hylobius abietis.

Microbial ecology (2017-01-12)
Karolin Axelsson, Vera Konstanzer, Gunaratna Kuttuva Rajarao, Olle Terenius, Lisa Seriot, Henrik Nordenhem, Göran Nordlander, Anna-Karin Borg-Karlson
ABSTRACT

The pine weevil, Hylobius abietis, is a severe forest pest insect as it feeds on newly planted conifer seedlings. To identify and develop an antifeedant could be one step towards the protection of seedlings from feeding damage by the pine weevil. With the aim to trace the origin of the antifeedants previously found in feces of the pine weevil, we investigated the culturable bacteria associated with the gut and identified the volatiles they produced. Bacterial isolates were identified by 16S ribosomal RNA gene analysis. The volatile emissions of selected bacteria, cultivated on NB media or on the grated phloem of Scots pine twigs dispersed in water, were collected and analyzed by solid-phase microextraction gas chromatography-mass spectrometry. The bacterial isolates released a variety of compounds, among others 2-methoxyphenol, 2-phenylethanol, 3-methyl-1-butanol, 1-octen-3-ol, 3-octanone, dimethyl disulfide, and dimethyl trisulfide. A strong antifeedant effect was observed by 2-phenylethanol, which could thus be a good candidate for use to protect planted conifer seedlings against feeding damage caused by H. abietis.

MATERIALI
N° Catalogo
Marchio
Descrizione del prodotto

Supelco
Gruppo in fibra SPME divinilbenzene/carbossene/polidimetilsilossano (DVB/CAR/PDMS), needle size 24 ga, StableFlex
Supelco
Gruppo in fibra SPME divinilbenzene/carbossene/polidimetilsilossano (DVB/CAR/PDMS), needle size 24 ga, for use with manual holder
Supelco
Gruppo in fibra SPME divinilbenzene/carbossene/polidimetilsilossano (DVB/CAR/PDMS), needle size 23 ga, StableFlex, for use with autosampler
Supelco
Gruppo in fibra SPME divinilbenzene/carbossene/polidimetilsilossano (DVB/CAR/PDMS), needle size 23 ga, StableFlex, for use with manual holder or autosampler, fiber L 2 cm
Supelco
Gruppo in fibra SPME divinilbenzene/carbossene/polidimetilsilossano (DVB/CAR/PDMS), needle size 24 ga, StableFlex, for use with autosampler
Supelco
Unità fibra SPME polidimetilsilossano (PDMS), df 100 μm(PDMS, for use with autosampler, needle size 23 ga
Supelco
Unità fibra SPME polidimetilsilossano (PDMS), df 100 μm(PDMS, needle size 24 ga, for use with manual holder
Supelco
Unità fibra SPME polidimetilsilossano (PDMS), df 100 μm(PDMS, for use with autosampler, needle size 24 ga
Supelco
Gruppo in fibra SPME carbossene/polidimetilsilossano (CAR/PDMS), df 75 μm(CAR/PDMS, for use with manual holder, needle size 24 ga
Supelco
Gruppo fibre SPME polidimetilsilossano/divinilbenzene (PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, StableFlex, for use with autosampler
Supelco
Gruppo in fibra SPME carbossene/polidimetilsilossano (CAR/PDMS), df 85 μm(CAR/PDMS, needle size 24 ga, StableFlex, for use with autosampler
Supelco
Gruppo fibre SPME poliacrilato (PA), df 85 μm(PA, for use with autosampler, needle size 23 ga
Supelco
Gruppo in fibra SPME carbossene/polidimetilsilossano (CAR/PDMS), df 85 μm(CAR/PDMS, needle size 23 ga, StableFlex, for use with autosampler
Supelco
Gruppo fibre SPME polidimetilsilossano/divinilbenzene (PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, for use with manual holder
Supelco
Gruppo in fibra SPME carbossene/polidimetilsilossano (CAR/PDMS), df 75 μm(CAR/PDMS, needle size 24 ga, for use with autosampler
Supelco
Gruppo fibre SPME polidimetilsilossano/divinilbenzene (PDMS/DVB), df 65 μm(PDMS/DVB, needle size 23 ga, PDMS/DVB StableFlex, for use with autosampler
Supelco
Gruppo fibre SPME polidimetilsilossano/divinilbenzene (PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, StableFlex, for use with manual holder
Supelco
Gruppo fibre SPME poliacrilato (PA), df 85 μm(PA, for use with autosampler, needle size 24 ga
Supelco
Gruppo in fibra SPME carbossene/polidimetilsilossano (CAR/PDMS), df 85 μm(CAR/PDMS, needle size 24 ga, for use with manual holder, StableFlex fiber
Supelco
Gruppo fibre SPME polidimetilsilossano/divinilbenzene (PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, for use with autosampler
Supelco
Gruppo in fibra SPME carbossene/polidimetilsilossano (CAR/PDMS), df 75 μm(CAR/PDMS, needle size 23 ga, for use with autosampler
Supelco
Unità fibra SPME polidimetilsilossano (PDMS), df 100 μm(PDMS, for use with manual holder, needle size 23 ga
Supelco
Gruppo fibre SPME polidimetilsilossano/divinilbenzene (PDMS/DVB), df 65 μm(PDMS/DVB, for use with autosampler, needle size 23 ga
Supelco
SPME StableFlex fiber assortment kit, for use with manual holder
Supelco
Gruppo fibre SPME, rivestimento in glicole polietilenico (PEG) Carbowax, needle size 23 ga, df 60 μm(PEG, for use with autosampler
Supelco
SPME StableFlex fiber assortment kit, needle size 23 ga, for use with autosampler
Supelco
Gruppo in fibra SPME carbossene/polidimetilsilossano (CAR/PDMS), df 75 μm(CAR/PDMS, needle size 23 ga, for use with manual holder
Supelco
Gruppo fibre SPME polidimetilsilossano/divinilbenzene (PDMS/DVB), fused silica fiber, df 65 μm(PDMS/DVB, for use with manual holder, needle size 23 ga
Supelco
Gruppo fibre SPME poliacrilato (PA), df 85 μm(PA, for use with manual holder, needle size 24 ga
Supelco
Gruppo in fibra SPME divinilbenzene/carbossene/polidimetilsilossano (DVB/CAR/PDMS), for use with autosampler, needle size 23 ga, metal alloy fiber, fiber L 2 cm