Passa al contenuto
Merck
Tutte le immagini(1)

Documenti fondamentali

M0880

Sigma-Aldrich

Ethyl methanesulfonate

Ethyl methanesulfonate

liquid

Sinonimo/i:

Ethyl mesylate, Methanesulfonic acid ethyl ester

Autenticatiper visualizzare i prezzi riservati alla tua organizzazione & contrattuali

Scegli un formato

1 G
35,10 €
5 G
91,30 €
10 G
131,00 €
25 G
218,00 €
100 G
803,00 €

35,10 €


Per informazioni sulla disponibilità, contatta il Servizio Clienti.

Richiedi un ordine bulk

Scegli un formato

Cambia visualizzazione
1 G
35,10 €
5 G
91,30 €
10 G
131,00 €
25 G
218,00 €
100 G
803,00 €

About This Item

Formula condensata:
CH3SO3CH2CH3
Numero CAS:
Peso molecolare:
124.16
Beilstein:
773969
Numero CE:
Numero MDL:
Codice UNSPSC:
12352108
ID PubChem:
NACRES:
NA.25

35,10 €


Per informazioni sulla disponibilità, contatta il Servizio Clienti.

Richiedi un ordine bulk

Stato

liquid

Indice di rifrazione

n20/D 1.418 (lit.)

P. ebollizione

85-86 °C/10 mmHg (lit.)

Densità

1.206 g/mL at 20 °C

Stringa SMILE

CCOS(C)(=O)=O

InChI

1S/C3H8O3S/c1-3-6-7(2,4)5/h3H2,1-2H3
PLUBXMRUUVWRLT-UHFFFAOYSA-N

Cerchi prodotti simili? Visita Guida al confronto tra prodotti

Applicazioni

Ethyl methanesulfonate had been used for inducing mutation in mouse embryonic fibroblasts[1], yeast [2] human embryonic kidney cell lines[3] and human lymphocytes.[4]

Azioni biochim/fisiol

Ethyl methanesulfonate is a DNA ethylating agent, mutagenic to plants and animals and carcinogenic in mammals. It has been used as a model alkylating agent in studies of DNA repair processes.[5] EMS induces base substitutions of guanine-cytosine (G/C) to adenine-thymine (A/T). EMS also generates point mutations and single nucleotide polymorphisms in genomes.[6] EMS is potential chemical mutagen used for inducing mutation in rice, wheat and Arabidopsis thaliana.[7]

Pittogrammi

Health hazardExclamation mark

Avvertenze

Danger

Classi di pericolo

Acute Tox. 4 Oral - Carc. 1B - Eye Irrit. 2 - Muta. 1B - Repr. 2 - Skin Irrit. 2 - Skin Sens. 1

Codice della classe di stoccaggio

6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects

Classe di pericolosità dell'acqua (WGK)

WGK 3

Punto d’infiammabilità (°F)

212.0 °F

Punto d’infiammabilità (°C)

100 °C

Dispositivi di protezione individuale

Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter


Scegli una delle versioni più recenti:

Certificati d'analisi (COA)

Lot/Batch Number

Non trovi la versione di tuo interesse?

Se hai bisogno di una versione specifica, puoi cercare il certificato tramite il numero di lotto.

Possiedi già questo prodotto?

I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.

Visita l’Archivio dei documenti

I clienti hanno visto anche

Slide 1 of 2

1 of 2

Genotoxicity Effect of Ethyl Methanesulfonate on Root Tip Cells of Chilli (Capsicum annuum L.)
Devi AS and Mullainathan L
World Journal of Agricultural Sciences, 7(4), 368-374 (2011)
Jinzhu Li et al.
Genes, 11(11) (2020-10-30)
Lateral root development is a complex process regulated by numerous factors. An important role for sugar in lateral root development has been known for a while, but the underlying molecular basis still remains unclear. In this study, we first showed
Novel wine yeast with ARO4 and TYR1 mutations that overproduce `floral?aroma compounds 2-phenylethanol and 2-phenylethyl acetate
Cordente AG, et al.
Applied Microbiology and Biotechnology, 1-12 (2018)
Kade M Power et al.
PLoS genetics, 16(10), e1009052-e1009052 (2020-10-17)
Ciliary microtubules are subject to post-translational modifications that act as a "Tubulin Code" to regulate motor traffic, binding proteins and stability. In humans, loss of CCP1, a cytosolic carboxypeptidase and tubulin deglutamylating enzyme, causes infantile-onset neurodegeneration. In C. elegans, mutations
A Rapid and Precise Mutation-Activated Fluorescence Reporter for Analyzing Acute Mutagenesis Frequency
Birnbaum MD, et al.
Cell Chemical Biology (2018)

Articoli

Cancer research has revealed that the classical model of carcinogenesis, a three step process consisting of initiation, promotion, and progression, is not complete.

Domande

1–10 di 13 domande  
  1. How can I determine the shelf life / expiration / retest date of this product?

    1 risposta
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf

      Utile?

  2. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 risposta
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Utile?

  3. Does opening a bottle of EMS and thus exposing it to the air accelerates its decomposition? How much time after the first opening can we assume same efficiency? The bottle we got did have a screw cap but no plastic plug. Is that ok?

    1 risposta
    1. This product is packaged under argon in an amber glass bottle with a screw cap. This is the standard packaging for this item. The item is indicated as being moisture sensitive and care should be taken to prevent exposure to air to prevent hydrolysis. There is no specific stability study to determine a decomposition timeline, but water from the humidity from air could lead to hydrolysis. Therefore, it is recommended to store the reagent under a dried inert gas such as argon as directed in section 7.2 of the SDS.

      https://www.sigmaaldrich.com/sds/sigma/m0880?userType=anonymous

      Utile?

  4. How mM have the EMS solution (5G)?

    1 risposta
    1. This product is a neat or pure liquid and has not been diluted in a solvent. This material has a density of 1.206 g/mL and a molecular weight of 124.16 g/mol, with a calculated molarity of 9.71 M. The concentration may be determined as follows:
      M = 1.206 g/mL/124.16 g/mol *1000 = 9.71M

      Utile?

  5. Is it suitable to store item M0880, Ethyl methanesulfonate, at 4°C?

    1 risposta
    1. The recommended storage condition for item M0880, Ethyl methanesulfonate, is at ambient temperature (>5°C).

      Utile?

  6. The bottle has 10g of EMS. How much volume of EMS is present in the bottle? How to make a stock concentration and what are the suggested working concentrations?

    1 risposta
    1. Volume =Mass/Density = 10g/1.206 g/ml = 8.29 ml. This product is over-filled up to 5%, so the volume and mass will not necessarily be the exact volume calculated.

      Further, EMS is miscible in chloroform (200 mg/ml). EMS can be diluted to a concentration of 1% in water or serum-free medium and then added to a culture at a final concentration in the range of 200-300 mg/ml:
      https://b2b.sigmaaldrich.com/deepweb/assets/sigmaaldrich/product/documents/830/111/m0880pis.pdf

      Utile?

  7. Can I make the stock solution 1% in chloroform as the data sheet mentions that the EMS is immiscible in chloroform?

    1 risposta
    1. Yes, this product may be prepared as a 1% solution. The 1% solution would be the equivalent of 1g/100mL or 10mg/mL This product is miscible in chloroform at 200 mg/ml. Please see the link below to review the product datasheet for additional information:
      https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/product/documents/830/111/m0880pis.pdf

      Utile?

  8. I am using M0880, what should be its dissolving solution, like simply double distilled water or other, for preparing various percentage solution of EMS?

    1 risposta
    1. As per the product datasheet, a 1% EMS stock solution can be prepared by diluting in water, serum-free medium, or buffer. The typical working concentration is 200-300 ug/mL. This product is not sterile. Stock solutions should be filter sterilized prior to adding to cultures. Please see the link below to review the product datasheet:
      https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/product/documents/830/111/m0880pis.pdf

      Utile?

  9. How does Product M0880, Ethyl methanesulfonate (EMS), compare to Product 64292, which is the same chemical?

    1 risposta
    1. Product No. 64292 is tested for purity by a titration assay. Although M0880 is likely to be of similar quality, there is no purity assay performed on it.

      Utile?

  10. I have heard that I need to use sodium thiosulfate with Product M0880, Ethyl methanesulfonate (EMS), but I’m not sure how. Can you tell me?

    1 risposta
    1. EMS is a mutagen. After treating cells with EMS, the mutagenesis reaction may be stopped by adding the appropriate volume of a 5% sodium thiosulfate solution.The use of a 10% sodium thiosulfate solution with 1% TWEEN 20 has been used to clean surfaces and items such as pipettes that have been contaminated with EMS in mineral oil.

      Utile?

1–10 di 13 domande  

Recensioni

Filtri attivi

    • Recensione 1
    • Voti 0
    5 su 5 stelle.

    DMSO solution to dissolve EMS

    I am planing to use EMS M0880 for mutagenesis of plant seeds. can I use EMS mixuture with DMSO to prepare a final volume of 1 liter?

    Traduci con Google

    Utile?

    1. Risposta di Sigma-Aldrich Corporation:

      We have not tested M0880 for its solubility in DMSO, this would need to be tested in your lab. It is water soluble and can be diluted to a concentration of 1% in water.
      We encourage customers who experience problems with our products to contact us for additional technical support. Please visit https://www.sigmaaldrich.com/US/en/support/customer-support to submit a Product Technical Inquiry.

Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..

Contatta l'Assistenza Tecnica.