Ugrás a tartalomra
Merck

FLAAM

Sigma-Aldrich

Adenosine 5′-triphosphate (ATP) assay mix

lyophilized powder

Szinonimák:

ATP assay kit, ATP detection kit

Bejelentkezésa Szervezeti és Szerződéses árazás megtekintéséhez


About This Item

UNSPSC kód:
12352202
eCl@ss:
32160414
NACRES:
NA.84

Forma

lyophilized powder

Minőségi szint

használat

1 vial sufficient for ≥50 assays

technika/technikák

PCR: suitable

tárolási hőmérséklet

−20°C

Általános leírás

The Adenosine 5’-triphosphate (ATP) Bioluminescent Assay Kit may be employed for the quantitative bioluminescent determination of adenosine 5’-triphosphate (ATP) in samples containing 2x10–12 to 8x10–5 moles/liter. ATP is consumed and light is emitted when luciferase catalyzes the oxidation of D-luciferin.

Alkalmazás

Adenosine 5′-triphosphate (ATP) assay mix has also been used to measure the level of cellular ATP in ATP viability assay.
The ATP assay kit has been used to measure the level of cellular ATP present in isolated mitochondrial fractions from L. donovani promastigotes.

Komponensek

Contains luciferase, luciferin, MgSO4, EDTA, DTT, BSA, and Tricine buffer.

Feloldás

Reconstitute with 5 ml of sterile water.

Piktogramok

Corrosion

Figyelmeztetés

Danger

Figyelmeztető mondatok

Óvintézkedésre vonatkozó mondatok

Veszélyességi osztályok

Eye Dam. 1

Tárolási osztály kódja

11 - Combustible Solids

WGK

WGK 3

Lobbanási pont (F)

Not applicable

Lobbanási pont (C)

Not applicable

Egyéni védőeszköz

Eyeshields, Gloves, type N95 (US)


Válasszon a legfrissebb verziók közül:

Analitikai tanúsítványok (COA)

Lot/Batch Number

Nem találja a megfelelő verziót?

Ha egy adott verzióra van szüksége, a tétel- vagy cikkszám alapján rákereshet egy adott tanúsítványra.

Már rendelkezik ezzel a termékkel?

Az Ön által nemrégiben megvásárolt termékekre vonatkozó dokumentumokat a Dokumentumtárban találja.

Dokumentumtár megtekintése

Buse Cevatemre et al.
Chemico-biological interactions, 260, 248-255 (2016-10-11)
Despite the rapid advances in chemotherapy regimens, the outcome of patients with breast cancer is not satisfactory. One of the reasons of this dissatisfaction is that subsets of cells in tumors which referred as cancer stem cells (CSCs) show and/or
C J Williams et al.
Osteoarthritis and cartilage, 26(6), 797-806 (2018-03-27)
Mutations on chromosomes 5p (CCAL2) and 8q (CCAL1) have been linked to familial forms of calcium pyrophosphate deposition disease (CPDD). Mutations in the ANKH gene account for CCAL2, but the identity of CCAL1 has been elusive. Recently, a single Dutch
A trans-platinum (II) complex induces apoptosis in cancer stem cells of breast cancer
Aztopal N, et al.
Bioorganic & Medicinal Chemistry, 25(1), 269-276 (2017)
Guiping Sui et al.
American journal of physiology. Renal physiology, 306(3), F286-F298 (2013-11-29)
The urothelium is a newly recognized sensory structure that detects bladder fullness. Pivotal to this sensory role is the release of ATP from the urothelium. However, the routes for urothelial ATP release, its modulation by receptor-mediated pathways, and the autocrine/paracrine
Anita Jemec et al.
Environment international, 87, 20-32 (2015-12-08)
Within the FP7 EU project NanoValid a consortium of six partners jointly investigated the hazard of silver nanoparticles (AgNPs) paying special attention to methodical aspects that are important for providing high-quality ecotoxicity data. Laboratories were supplied with the same original

Tudóscsoportunk valamennyi kutatási területen rendelkezik tapasztalattal, beleértve az élettudományt, az anyagtudományt, a kémiai szintézist, a kromatográfiát, az analitikát és még sok más területet.

Lépjen kapcsolatba a szaktanácsadással