跳转至内容
Merck
  • Trace analysis of total naphthenic acids in aqueous environmental matrices by liquid chromatography/mass spectrometry-quadrupole time of flight mass spectrometry direct injection.

Trace analysis of total naphthenic acids in aqueous environmental matrices by liquid chromatography/mass spectrometry-quadrupole time of flight mass spectrometry direct injection.

Journal of chromatography. A (2015-06-16)
Pamela Brunswick, Dayue Shang, Graham van Aggelen, Ralph Hindle, L Mark Hewitt, Richard A Frank, Maxine Haberl, Marcus Kim
摘要

A rapid and sensitive liquid chromatography quadrupole time of flight method has been established for the determination of total naphthenic acid concentrations in aqueous samples. This is the first methodology that has been adopted for routine, high resolution, high throughput analysis of total naphthenic acids at trace levels in unprocessed samples. A calibration range from 0.02 to 1.0μgmL(-1) total Merichem naphthenic acids was validated and demonstrated excellent accuracy (97-111% recovery) and precision (1.9% RSD at 0.02μgmL(-1)). Quantitative validation was also demonstrated in a non-commercial oil sands process water (OSPW) acid extractable organics (AEOs) fraction containing a higher percentage of polycarboxylic acid isomers than the Merichem technical mix. The chromatographic method showed good calibration linearity of ≥0.999 RSQ to 0.005μgmL(-1) total naphthenic acids with a precision <3.1% RSD and a calculated detection limit of 0.0004μgmL(-1) employing Merichem technical mix reference material. The method is well suited to monitoring naturally occurring and industrially derived naphthenic acids (and other AEOs) present in surface and ground waters in the vicinity of mining developments. The advantage of the current method is its direct application to unprocessed environmental samples and to examine natural naphthenic acid isomer profiles. It is noted that where the isomer profile of samples differs from that of the reference material, results should be considered semi-quantitative due to the lack of matching isomer content. The fingerprint profile of naphthenic acids is known to be transitory during aging and the present method has the ability to adapt to monitoring of these changes in naphthenic acid content. The method's total ion scan approach allows for data previously collected to be examined retrospectively for specific analyte mass ions of interest. A list of potential naphthenic acid isomers that decrease in response with aging is proposed and a quantitative assay of an adamantane carboxylic acid is reported.

材料
货号
品牌
产品描述

Sigma-Aldrich
甲醛 溶液, for molecular biology, 36.5-38% in H2O
Sigma-Aldrich
异丙醇, ≥99.7%, FCC, FG
Sigma-Aldrich
乙腈, anhydrous, 99.8%
Sigma-Aldrich
甲醛 溶液, for molecular biology, BioReagent, ≥36.0% in H2O (T)
Sigma-Aldrich
2-丙醇, BioUltra, for molecular biology, ≥99.5% (GC)
Sigma-Aldrich
氟化铵, ≥99.99% trace metals basis
Sigma-Aldrich
甲醇, JIS special grade, ≥99.8%
Sigma-Aldrich
乙酸, for luminescence, BioUltra, ≥99.5% (GC)
Sigma-Aldrich
2-丙醇, electronic grade, 99.999% trace metals basis
Sigma-Aldrich
2-丙醇, for molecular biology, BioReagent, ≥99.5%
Sigma-Aldrich
甲醇, anhydrous, 99.8%
Sigma-Aldrich
乙酸, ≥99.5%, FCC, FG
Sigma-Aldrich
2-丙醇, anhydrous, 99.5%
Sigma-Aldrich
甲醛 溶液, ACS reagent, 37 wt. % in H2O, contains 10-15% Methanol as stabilizer (to prevent polymerization)
Sigma-Aldrich
乙酸, natural, ≥99.5%, FG
Sigma-Aldrich
甲醇, SAJ first grade, ≥99.5%
Sigma-Aldrich
5α-雄甾烷-17β-醇-3-酮, ≥97.5%
Sigma-Aldrich
2-丙醇, JIS special grade, ≥99.5%
Sigma-Aldrich
1-金刚烷甲酸, 99%
Sigma-Aldrich
乙酸, ≥99.7%
Sigma-Aldrich
乙酸, JIS special grade, ≥99.7%
Sigma-Aldrich
乙腈, electronic grade, 99.999% trace metals basis
Sigma-Aldrich
甲醛 溶液, meets analytical specification of USP, ≥34.5 wt. %
Supelco
乙腈, HPLC grade, ≥99.93%
Sigma-Aldrich
甲醇, suitable for HPLC
Sigma-Aldrich
甲醇, SAJ special grade
Sigma-Aldrich
乙酸, SAJ first grade, ≥99.0%
Sigma-Aldrich
乙腈, ≥99.8%, suitable for HPLC
Sigma-Aldrich
乙酸 溶液, 1 M, 1 N
Sigma-Aldrich
乙腈, HPLC Plus, ≥99.9%, poly-coated bottles