跳转至内容
Merck
  • Determination of irinotecan and its metabolite SN-38 in rabbit plasma and tumors using a validated method of tandem mass spectrometry coupled with liquid chromatography.

Determination of irinotecan and its metabolite SN-38 in rabbit plasma and tumors using a validated method of tandem mass spectrometry coupled with liquid chromatography.

Journal of chromatography. B, Analytical technologies in the biomedical and life sciences (2014-06-14)
Dae J Park, Jun H Won, A R Cho, Hye J Yun, Jeong H Heo, Tae H Hwhang, Dae H Lee, Woo M Kim
摘要

New tandem mass spectrometric method coupled with liquid chromatography (LC-MS/MS) has been developed to determine the total concentration of camptothecin derivatives (irinotecan and SN-38) regardless of inter-conversion phenomenon between carboxylate and lactone forms. At first, all sample solutions were acidified for 1h in order to completely convert CPT derivatives into their lactone forms and then CPT derivatives were extracted with organic solution containing diethyl ether and ethyl acetate (2:1, v/v) just after alkalization in the range pH 8.0-8.5 in acid-treated solutions. Analytes were separated on a reverse phase C18 column (150×2.1mm) and eluted isocratically with a mobile phase which consisted of acetonitrile-methanol-buffer (0.1% formic acid, 5mM ammonium formate) (3:4:3, v/v). CPT derivatives were monitored by tandem mass spectrometry in electrospay-positive ionization and multiple reaction mode programmed to the following transitions (m/z): '587.6→167.2' of CPT-11, '393.6→349.3' of SN-38 and '349.4→ 305.2' of CPT. The method was validated to have the proper linearity (r(2)>0.99) over the range of 5-1000ng/ml of CPT-11 and 1-250ng/ml of SN-38 with good accuracy (89.8-114.3%) and precision (less than 10%). In all stability tests, concentration of CPT-11 and SN-38 had been left in the acceptable range of 88.8-110.7% when sample solutions were acidified before determination of CPT derivatives. Newly developed LC-MS/MS method was suitable for the determination of CPT derivatives of both rabbit plasma and tumor tissues in the pharmacokinetic study.

材料
货号
品牌
产品描述

Sigma-Aldrich
乙腈, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
甲醇, suitable for HPLC, ≥99.9%
Sigma-Aldrich
甲醇, ACS reagent, ≥99.8%
Sigma-Aldrich
乙酸乙酯, ACS reagent, ≥99.5%
Sigma-Aldrich
乙腈, HPLC Plus, ≥99.9%
Sigma-Aldrich
甲醇, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
乙酸乙酯, suitable for HPLC, ≥99.7%
Sigma-Aldrich
二乙醚, anhydrous, ACS reagent, ≥99.0%, contains BHT as inhibitor
Sigma-Aldrich
甲酸, reagent grade, ≥95%
Sigma-Aldrich
甲醇, HPLC Plus, ≥99.9%
Sigma-Aldrich
二乙醚, suitable for HPLC, ≥99.9%, inhibitor-free
Sigma-Aldrich
乙酸乙酯, HPLC Plus, for HPLC, GC, and residue analysis, 99.9%
Sigma-Aldrich
甲酸, ACS reagent, ≥96%
Sigma-Aldrich
二乙醚, ACS reagent, anhydrous, ≥99.0%, contains BHT as inhibitor
Sigma-Aldrich
甲酸, puriss. p.a., ACS reagent, reag. Ph. Eur., ≥98%
Sigma-Aldrich
乙腈, ACS reagent, ≥99.5%
Sigma-Aldrich
甲酸铵, reagent grade, 97%
Sigma-Aldrich
乙腈, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
甲醇, suitable for HPLC, gradient grade, suitable as ACS-grade LC reagent, ≥99.9%
Sigma-Aldrich
甲醇, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.8% (GC)
Sigma-Aldrich
乙腈, anhydrous, 99.8%
Sigma-Aldrich
甲酸, puriss., meets analytical specifications of DAC, FCC, 98.0-100%
Sigma-Aldrich
甲醇, Laboratory Reagent, ≥99.6%
Sigma-Aldrich
甲酸铵, ≥99.995% trace metals basis
Sigma-Aldrich
甲酸, ACS reagent, ≥88%
Sigma-Aldrich
乙酸乙酯, suitable for HPLC, ≥99.8%
Sigma-Aldrich
二乙醚, contains BHT as inhibitor, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.8% (GC)
Sigma-Aldrich
甲醇, BioReagent, ≥99.93%
Sigma-Aldrich
甲醇, Absolute - Acetone free
Sigma-Aldrich
乙酸乙酯, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.5% (GC)