Investigation of nonylphenol and nonylphenol ethoxylates in sewage sludge samples from a metropolitan wastewater treatment plant in Turkey.

Talanta (2014-10-05)
Seçil Ömeroğlu, Fadime Kara Murdoch, F Dilek Sanin
摘要

Nonylphenol ethoxylates (NPEOs) have drawn significant attention within the last decade for both scientific and legislative reasons. In Turkey, the Regulation Regarding the Use of Domestic and Urban Sludges on Land states a limit value for the sum of nonylphenol (NP), nonylphenol monoethoxylate (NP1EO) and nonylphenol diethoxylate (NP2EO) as NPE (NPE=NP+NP1EO+NP2EO). Unfortunately a standard method for the determination of these chemicals has not been yet set by the authorities and no data exists about the concentrations of NP and NPEOs in sewage sludge in Turkey. The aim of this study is to propose simple and easily applicable extraction and measurement techniques for 4-n-nonylphenol (4-n-NP), NP, NP1EO and NP2EO in sewage sludge samples and investigate the year round concentrations in a Metropolitan Wastewater Treatment Plant (WWTP) in Turkey. Different extraction techniques and GC/MS methods for sewage sludge were tested. The best extraction method for these compounds was found to be ultrasonication (5 min) using acetone as the solvent with acceptable recovery of analytes suggested by USEPA and other studies. The optimized extraction method showed good repeatability with relative standard deviations (RSDs) less than 6%. The recovery of analytes were within acceptable limits suggested by USEPA and other studies. The limits of detection (LODs) were 6 µg kg(-1) for NP and NP1EO, 12 µg kg(-1) for NP2EO and 0.03 µg kg(-1) for 4-n-NP. The developed method was applied to sewage sludge samples obtained from the Central WWTP in Ankara, Turkey. The sum NPE (NP+NP1EO+NP2EO) was found to be in between 5.5 µg kg(-1) and 19.5 µg kg(-1), values which are in compliance with Turkish and European regulations.

材料
货号
品牌
产品描述

Sigma-Aldrich
甲醇, suitable for HPLC, ≥99.9%
Sigma-Aldrich
二氯甲烷, suitable for HPLC, ≥99.8%, contains amylene as stabilizer
Sigma-Aldrich
甲醇, ACS reagent, ≥99.8%
Sigma-Aldrich
二氯甲烷, contains 40-150 ppm amylene as stabilizer, ACS reagent, ≥99.5%
Sigma-Aldrich
甲醇, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
甲醇, HPLC Plus, ≥99.9%
Sigma-Aldrich
二氯甲烷, HPLC Plus, for HPLC, GC, and residue analysis, ≥99.9%, contains 50-150 ppm amylene as stabilizer
Sigma-Aldrich
正己烷, suitable for HPLC, ≥97.0% (GC)
Sigma-Aldrich
正己烷, ReagentPlus®, ≥99%
Sigma-Aldrich
正己烷, suitable for HPLC, ≥95%
Sigma-Aldrich
环己烷, ACS reagent, ≥99%
Sigma-Aldrich
环己烷, suitable for HPLC, ≥99.9%
Sigma-Aldrich
正己烷, Laboratory Reagent, ≥95%
Sigma-Aldrich
甲醇, suitable for HPLC, gradient grade, suitable as ACS-grade LC reagent, ≥99.9%
Sigma-Aldrich
正己烷, puriss. p.a., ACS reagent, reag. Ph. Eur., ≥99% (GC)
Sigma-Aldrich
甲醇, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.8% (GC)
Sigma-Aldrich
正己烷, HPLC Plus, for HPLC, GC, and residue analysis, ≥95%
Sigma-Aldrich
二氯甲烷, ACS reagent, ≥99.5%, contains 40-150 ppm amylene as stabilizer
Supelco
N,O-双(三甲基硅)三氟乙酰胺(含三甲基氯硅烷), with 1% trimethylchlorosilane, for GC derivatization, LiChropur
Sigma-Aldrich
甲醇, Laboratory Reagent, ≥99.6%
Sigma-Aldrich
三甲基氯硅烷, ≥98.0% (GC)
Sigma-Aldrich
二氯甲烷, puriss. p.a., ACS reagent, reag. ISO, ≥99.9% (GC)
Sigma-Aldrich
环己烷, suitable for HPLC, ≥99.7%
Sigma-Aldrich
乙酸酐, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99% (GC)
Sigma-Aldrich
甲醇, ACS spectrophotometric grade, ≥99.9%
Sigma-Aldrich
甲醇, Absolute - Acetone free
Sigma-Aldrich
三甲基氯硅烷, purified by redistillation, ≥99%
Sigma-Aldrich
甲醇, BioReagent, ≥99.93%
Sigma-Aldrich
环己烷, puriss. p.a., ACS reagent, ≥99.5% (GC)
Sigma-Aldrich
N,O-双(三甲基硅基)三氟乙酰胺, ≥99%