跳转至内容
Merck

719889

Sigma-Aldrich

Resomer® RG 502,聚(D,L-丙交酯-co-乙交酯)

lactide:glycolide 50:50, ester terminated, Mw 7,000-17,000

别名:

RESOMER® RG 502

登录查看公司和协议定价


About This Item

线性分子式:
[C3H4O2]x[C2H2O2]y
分類程式碼代碼:
12162002
NACRES:
NA.23

形狀

amorphous

饋電比

lactide:glycolide 50:50

分子量

Mw 7,000-17,000

降解時間

<3 months

黏度

0.16-0.24 dL/g, 0.1 % (w/v) in chloroform(25 °C, Ubbelohde) (size 0c glass capillary viscometer)

轉變溫度

Tg 42-46 °C

運輸包裝

wet ice

儲存溫度

2-8°C

應用

Resomer® RG 502可用于制备基于PLGA的纳米 药物递送系统,用于抗炎药物6-溴靛玉红-3′-甘油肟醚(6BIGOE)。

它还可用于制备盐酸纳洛酮递送的控制释放。

特點和優勢

  • 生物相容性
  • 生物可降解
  • 可加工成几乎任何形状和尺寸
  • 机械性能可调

法律資訊

Evonik产品
RESOMER is a registered trademark of Evonik Rohm GmbH

儲存類別代碼

11 - Combustible Solids

水污染物質分類(WGK)

WGK 3

閃點(°F)

Not applicable

閃點(°C)

Not applicable


分析证书(COA)

输入产品批号来搜索 分析证书(COA) 。批号可以在产品标签上"批“ (Lot或Batch)字后找到。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

Yung-Hsin Cheng et al.
Experimental eye research, 179, 179-187 (2018-11-25)
Elevated intraocular pressure (IOP) in glaucoma is due to impairment of aqueous humor drainage via the uveoscleral or trabecular outflow pathway. Latanoprost reduces IOP by increasing the uveoscleral outflow. Despite its potency, long-term daily application of it may cause undesirable
Rongcai Liang et al.
International journal of pharmaceutics, 454(1), 344-353 (2013-07-23)
Peptide or protein degradation often occurs when water flows into the dosage form. The aim of this study was to investigate the effect of water on exenatide acylation in poly(lactide-co-glycolide) (PLGA) microspheres. Exenatide-loaded PLGA microspheres were incubated at different relative
Teresa Musumeci et al.
International journal of pharmaceutics, 440(2), 135-140 (2012-10-20)
Melatonin, a neurohormone secreted by the pineal gland, is able to modulate intraocular pressure (IOP). The aim of this study was to generate nanoparticle (NPs) sustained release formulations that allow to extend the pre-corneal residence time of melatonin, thus prolonging
Igor Jeroukhimov et al.
Journal of the American College of Surgeons, 218(1), 102-107 (2013-11-12)
Chronic pain after inguinal hernia repair occurs in 16% to 62% of patients. The underlying mechanism probably involves sensory nerve damage and abnormal healing that might be influenced by the materials chosen for the procedure. We hypothesize that nonabsorbable sutures
Hannu Paajanen et al.
International journal of surgery (London, England), 11(1), 81-84 (2012-12-19)
Chronic pain may be a major long-term problem related to mesh material and operative trauma in inguinal hernioplasty. Lichtenstein hernioplasty was performed under local anaesthesia in 312 patients by the same surgeon and technique between 2003 and 2005. The patients

商品

Interest in utilizing biodegradable polymers for biomedical applications has grown since the 1960s.

Synthetic aliphatic polyesters dominate resorbable biomaterials in clinical use.

商业生物材料已停滞不前超过30年的时间,因为很少有材料能够成功地从实验台过渡到临床使用。合成型脂族聚酯因其悠久的历史和获得美国食品药品监督管理局(FDA)批准的记录,一直在可吸收生物材料领域占据主导地位。

AliAliphatic polyesters, including polylactide and polyglycolide, are biodegradable polymers widely used in medical applications.

查看所有结果

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系技术服务部门