parameter
6000 psi max. pressure
L × O.D. × I.D.
10 ft × 1/16 in. × 0.010 in.
color
blue
Hledáte podobné produkty? Navštivte Průvodce porovnáváním produktů
General description
Polyetheretherketone (PEEK) tubing has become a popular replacement for stainless steel tubing in various places in the HPLC system. It is especially useful when contact between the sample and metal components must be avoided, such as when working with metal complexing agents or certain biochemical compounds. PEEK tubing also offers other advantages: it is flexible, easy to cut, has excellent mechanical stability and chemical compatibility, and can be used to 100 °C. Tetrahydrofuran (THF), dimethyl sulfoxide (DMSO), methylene chloride, and concentrated nitric and sulfuric acids should not be used with PEEK tubing. Our 1/16 in. PEEK tubing is color coded for easy identification of the internal diameter. 10 ft./3 m length.
Application
Polyetheretherketone (PEEK) connecting tubing may be used as a solvent holder and as the fluid delivery duct while being immersed in a continuously flowing sample solution, in a liquid-liquid microextraction method termed as continuous-flow microextraction (CFME) for dilute analytes. It may also be used in a flow through cell, in experiments performed to measure the solubility of zinc oxide from 150 to 300°C.
Vyberte jednu z posledních verzí:
Osvědčení o analýze (COA)
Je nám líto, ale pro tento produkt momentálně nemáme COA k dispozici online.
Potřebujete-li pomoc, obraťte se na Zákaznická podpora
Již tento produkt vlastníte?
Dokumenty související s produkty, které jste v minulosti zakoupili, byly za účelem usnadnění shromážděny ve vaší Knihovně dokumentů.
Zákazníci si také prohlíželi
Analytical chemistry, 72(18), 4462-4467 (2000-09-29)
A novel liquid-liquid microextraction method, that we have termed continuous-flow microextraction (CFME), is described. In a 0.5-mL glass chamber, an organic drop (1-5 microL) is held at the outlet tip of a polyetheretherketone (PEEK) connecting tubing which is immersed in
New measurements of the solubility of zinc oxide from 150 to 350 C.
Journal of Solution Chemistry, 31 (12), 947-973 (2002)
Náš tým vědeckých pracovníků má zkušenosti ve všech oblastech výzkumu, včetně přírodních věd, materiálových věd, chemické syntézy, chromatografie, analytiky a mnoha dalších..
Obraťte se na technický servis.