Přejít k obsahu
Merck
Všechny fotografie(2)

Hlavní dokumenty

T0656

Sigma-Aldrich

1,3,4,6-Tetrachloro-3α,6α-diphenylglycouril

Synonyma:

Iodo-Gen®, NSC 4462

Přihlásitk zobrazení cen stanovených pro organizaci a smluvních cen


About This Item

Empirický vzorec (Hillův zápis):
C16H10Cl4N4O2
Číslo CAS:
Molekulová hmotnost:
432.09
MDL number:
UNSPSC Code:
12352101
PubChem Substance ID:
NACRES:
NA.22

storage temp.

2-8°C

Quality Level

SMILES string

ClN1C(=O)N(Cl)C2(N(Cl)C(=O)N(Cl)C12c3ccccc3)c4ccccc4

InChI

1S/C16H10Cl4N4O2/c17-21-13(25)23(19)16(12-9-5-2-6-10-12)15(21,11-7-3-1-4-8-11)22(18)14(26)24(16)20/h1-10H

InChI key

FJQZXCPWAGYPSD-UHFFFAOYSA-N

Hledáte podobné produkty? Navštivte Průvodce porovnáváním produktů

Application

Iodination reagent used in radioiodination acting as an oxidative agent

Reagent involved in comparison studies with chloramine-T

Reagent used for oxidation of urazoles

Legal Information

Iodo-Gen is a registered trademark of Pierce Biotechnology, Inc.

pictograms

Exclamation mark

signalword

Warning

Hazard Classifications

Eye Irrit. 2 - Skin Irrit. 2 - STOT SE 3

target_organs

Respiratory system

Storage Class

11 - Combustible Solids

wgk_germany

WGK 3

flash_point_f

Not applicable

flash_point_c

Not applicable

ppe

dust mask type N95 (US), Eyeshields, Gloves


Osvědčení o analýze (COA)

Vyhledejte osvědčení Osvědčení o analýze (COA) zadáním čísla šarže/dávky těchto produktů. Čísla šarže a dávky lze nalézt na štítku produktu za slovy „Lot“ nebo „Batch“.

Již tento produkt vlastníte?

Dokumenty související s produkty, které jste v minulosti zakoupili, byly za účelem usnadnění shromážděny ve vaší Knihovně dokumentů.

Navštívit knihovnu dokumentů

Miro J Eigenmann et al.
The Journal of physiology, 595(24), 7311-7330 (2017-09-30)
For therapeutic antibodies, total tissue concentrations are frequently reported as a lump sum measure of the antibody in residual plasma, interstitial fluid and cells. In terms of correlating antibody exposure to a therapeutic effect, however, interstitial pharmacokinetics might be more
Th M Behr et al.
Nuklearmedizin. Nuclear medicine, 41(2), 71-79 (2002-05-07)
Simple and reliable methodologies for radioiodination of proteins and peptides are described. The labeling systems are easy to assemble, capable of radioiodinating any protein or, with slight modifications, also peptide (molecular mass 1000-300,000) from kBq to GBq levels of activity
Bernard M Tijink et al.
European journal of nuclear medicine and molecular imaging, 36(8), 1235-1244 (2009-03-05)
The human monoclonal antibody (MAb) fragment L19-SIP is directed against extra domain B (ED-B) of fibronectin, a marker of tumour angiogenesis. A clinical radioimmunotherapy (RIT) trial with (131)I-L19-SIP was recently started. In the present study, after GMP production of (124)I
Ulla Lund et al.
American journal of physiology. Renal physiology, 284(6), F1226-F1234 (2003-03-07)
The size and charge-selective properties of the glomerular barrier are partly controversial. Glomerular sieving coefficients (theta) for proteins have rarely been determined noninvasively before in vivo. Therefore, theta was assessed vs. glomerular filtration rate (GFR; (51)Cr-EDTA clearance) in intact rats
P K Garg et al.
Bioconjugate chemistry, 7(2), 233-239 (1996-03-01)
Two peptides of potential utility for targeting melanoma cells, alpha-melanocyte-stimulating hormone (alpha-MSH) and its more potent analogue [Nle4,D-Phe7]-alpha-MSH, were radioiodinated in 45-65% yield using N-succinimidyl 3-[125I]iodobenzoate (SIB). To determine whether this labeling method resulted in improved in vitro and in

Náš tým vědeckých pracovníků má zkušenosti ve všech oblastech výzkumu, včetně přírodních věd, materiálových věd, chemické syntézy, chromatografie, analytiky a mnoha dalších..