Přejít k obsahu
Merck

5C44

NovaSeptum® GO Conical Tube Sampling Unit, Manifold (5-valve) with Inlet C-Flex® Tubing

sterile; γ-irradiated, volume × volume 15 mL × 50 mL


Přihlásit pro zobrazení organizačních a smluvních cen.

Vybrat velikost

Informace o stanovených cenách a dostupnosti nejsou v současnosti dostupné.

O této položce

UNSPSC Code:
41104019

Přeskočit na

Technický servis
Potřebujete pomoc? Náš tým zkušených odborníků je vám k dispozici.
Dovolte nám, abychom vám pomohli

material

TPE tubing (Inlet C-Flex), polycarbonate Luer lock, polypropylene clip (TTP clip), polypropylene tube (Fluid contact layer (conical tube)), polystyrene tube (Fluid contact layer (conical tube)), tubing (Female and male Luer-Lok®)

agency

according to ISO 11137 (sterilization), according to ISO Clean Room Class 8 conditions in a facility, certified by the ISO 14644-1 standards, meets USP 88 biological reactivity (all component materials)

sterility

sterile; γ-irradiated

product line

NovaSeptum® GO

feature

autoclavable: no

parameter

max. pressure at 0.50 bar (7.25 psi), 2-60 °C temp. range (36-140 °F)

volume × volume

15 mL × 50 mL

Quality Level

application(s)

cell therapy
gene therapy
life science and biopharma
mAb
ophthalmics
parenterals
pharma/biopharma processes
sterile sampling
viral therapy

storage temp.

2-30°C

Porovnat podobné položky

Zobrazit úplné porovnání

Zobrazit rozdíly

1 of 4

Tato položka
5D445C41ED71
product line

NovaSeptum® GO

product line

NovaSeptum® GO

product line

NovaSeptum® GO

product line

NovaSeptum® GO

sterility

sterile; γ-irradiated

sterility

sterile; γ-irradiated

sterility

sterile; γ-irradiated

sterility

sterile; γ-irradiated

material

TPE tubing (Inlet C-Flex), polypropylene clip (TTP clip), polystyrene tube (Fluid contact layer (conical tube)), polycarbonate Luer lock, tubing (Female and male Luer-Lok®), polypropylene tube (Fluid contact layer (conical tube))

material

TPE tubing (Inlet C-Flex), polycarbonate Luer lock, polypropylene clip (TTP clip), polypropylene tube (Fluid contact layer (conical tube)), polystyrene tube (Fluid contact layer (conical tube))

material

TPE tubing (Inlet C-Flex), polycarbonate Luer lock, polypropylene clip (TTP clip), polypropylene tube (Fluid contact layer (conical tube)), polystyrene tube (Fluid contact layer (conical tube))

material

316 stainless steel cannula (ASTM®), TPE tubing (Thermoplastic elastomer), polyester body, polypropylene clip (TTP clip), polypropylene tube (Fluid contact layer (conical tube)), polystyrene tube (Fluid contact layer (conical tube)), silicone septum (Platinum-cured)

agency

according to ISO 11137 (sterilization)

agency

according to ISO 11137 (sterilization), according to ISO Clean Room Class 8 conditions in a facility, certified by the ISO 14644-1 standards, meets USP 88 biological reactivity (all component materials)

agency

according to ISO 11137 (sterilization), according to ISO Clean Room Class 8 conditions in a facility, certified by the ISO 14644-1 standards, meets USP 88 biological reactivity (all component materials)

agency

according to ISO 11137 (sterilization), according to ISO Clean Room Class 8 conditions in a facility, certified by the ISO 14644-1 standards, meets USP 88 biological reactivity (all component materials)

feature

autoclavable: no

feature

autoclavable: no

feature

autoclavable: no

feature

autoclavable: no

parameter

max. pressure at 0.50 bar (7.25 psi)

parameter

max. pressure at 0.50 bar (7.25 psi), 2-60 °C temp. range (36-140 °F)

parameter

max. pressure at 0.50 bar (7.25 psi), 2-60 °C temp. range (36-140 °F)

parameter

max. pressure at 0.50 bar (7.25 psi), 2-50 °C temp. range (36-112 °F)

General description

Device configuration: single Unit Sampling
NovaSeptum® GO Conical Tube Sampling Unit, Manifold (5-valve) with Inlet C-Flex® Tubing are small volume sampling containers that fit our established NovaSeptum® GO sampling system. These sampling containers are available in two sizes: 15 mL polystyrene tubes ideal for endotoxin testing, and 50 mL polypropylene tubes for bioburden and other physico-chemical tests. These conical tubes provide flexibility to manufacturers for sampling at any point in the production process eliminating the need to aliquot.

When used in a single-use manufacturing process, a weldable option with C-Flex® tubing is available.

The NovaSeptum® GO Conical Tube Sampling Unit offers you flexibility while minimizing the risk of both product and process contamination.

Application

Sterility testing, pyrogenic testing, endotoxin testing, chemical analysis, pH analysis, fermentation applications or any other routine lab testing
supported liquid extraction

Features and Benefits

Fluid contact layer made of polystyrene, ideal for endotoxin testingSmall size, no need to aliquot, Manifold Format, C-Flex inlet weldable

Packaging

8 units per box

Other Notes

Luer: Polycarbonate

Fluid contact layer (conical tube): Polystyrene (15mL) and Polypropylene (50mL), dip tube: LDPE (Low density polyethylene pharmalene FL20PH)

TTP clip Polypropylène (15mL only)

Tubing: Thermoplastic elastomer (TPE), Inlet C-Flex

Outlet Tubing: Female and male Luer-Lok®

Legal Information

C-Flex is a registered trademark of Saint-Gobain Performance Plastics Corp.
Luer-Lok is a registered trademark of Becton-Dickinson & Co.
NOVASEPTUM is a registered trademark of Merck KGaA, Darmstadt, Germany

related product

Č. produktu
Popis
Stanovení ceny

Osvědčení o analýze (COA)

Vyhledejte osvědčení Osvědčení o analýze (COA) zadáním čísla šarže/dávky těchto produktů. Čísla šarže a dávky lze nalézt na štítku produktu za slovy „Lot“ nebo „Batch“.

Již tento produkt vlastníte?

Dokumenty související s produkty, které jste v minulosti zakoupili, byly za účelem usnadnění shromážděny ve vaší Knihovně dokumentů.

Navštívit knihovnu dokumentů

Sortimentní položky

Ensure sample integrity and accurate results with NovaSeptum® sterile sampling containers: bags, bottles, syringes & more.

Související obsah

NovaSeptum® GO sterile sampling unit with 15 mL single-use conical tube for small volume and endotoxin sampling. Closed design for aseptic process. Reduce product loss and risks of contamination. Available in single and manifold sampling format. Easily integrated into stainless-steel system via multi-use connection types (TC, in-line, ingold®).

Questions

Reviews

No rating value

Active Filters

Náš tým vědeckých pracovníků má zkušenosti ve všech oblastech výzkumu, včetně přírodních věd, materiálových věd, chemické syntézy, chromatografie, analytiky a mnoha dalších..

Obraťte se na technický servis