Direkt zum Inhalt
Merck
  • Simultaneous determination of bambuterol and its two major metabolites in human plasma by hydrophilic interaction ultra-performance liquid chromatography-tandem mass spectrometry.

Simultaneous determination of bambuterol and its two major metabolites in human plasma by hydrophilic interaction ultra-performance liquid chromatography-tandem mass spectrometry.

Journal of chromatography. B, Analytical technologies in the biomedical and life sciences (2014-08-17)
Ting Zhou, Qing Cheng, Chengjuan Zou, Ting Zhao, Shan Liu, Marco Pistolozzi, Evina Tan, Ling Xu, Wen Tan
ZUSAMMENFASSUNG

In this study, a rapid and sensitive hydrophilic interaction ultra-performance liquid chromatography-tandem mass spectrometry (HILIC-UPLC-MS/MS) method was developed for simultaneous determination of bambuterol and its two major metabolites monocarbamate bambuterol and terbutaline in human plasma. All samples were simply precipitated using acetonitrile and separated on a UPLC-HILIC column under gradient elution with a mobile phase consisting of acetonitrile and water with the addition of 10mm ammonium acetate and 0.1% formic acid at 0.4 mL/min. The analytes were detected by a Xevo TQ-S tandem mass spectrometer with positive electrospray ionization in multiple reaction monitoring mode. The established method was highly sensitive with the lower limit of quantification (LLOQ) of 10.00 pg/mL for each analyte, and the intra- and inter-day precisions were <12.8%. The analytical runtime within 4.0 min per sample made this method suitable for high throughput determination. The validated method was successfully applied to a clinical pharmacokinetic study of bambuterol in eight healthy volunteers. Furthermore, the effects of the chromatographic conditions on the retention of the analytes on HILIC were investigated, and the benefits of HILIC were evaluated by comparing with a C18 column. The results indicated that liquid-liquid partition and the electrostatic interactions played an important role in the retention of the analytes on HILIC in this study. And HILIC offered particular advantages over RPLC approach in the aspects of the peak symmetry, the column efficiency, and the column pressure.

MATERIALIEN
Produktnummer
Marke
Produktbeschreibung

Sigma-Aldrich
Acetonitril, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Methanol, suitable for HPLC, ≥99.9%
Sigma-Aldrich
Methanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Ethylacetat, ACS reagent, ≥99.5%
Sigma-Aldrich
Acetonitril, HPLC Plus, ≥99.9%
Sigma-Aldrich
Methanol, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Ethylacetat, suitable for HPLC, ≥99.7%
Sigma-Aldrich
Ameisensäure, reagent grade, ≥95%
Sigma-Aldrich
Methanol, HPLC Plus, ≥99.9%
Sigma-Aldrich
Ethylacetat, HPLC Plus, for HPLC, GC, and residue analysis, 99.9%
Sigma-Aldrich
Ameisensäure, ACS reagent, ≥96%
Sigma-Aldrich
Natriumcarbonat, powder, ≥99.5%, ACS reagent
Sigma-Aldrich
Acetonitril, anhydrous, 99.8%
Sigma-Aldrich
Ammoniumacetat, ACS reagent, ≥97%
Sigma-Aldrich
Acetonitril, ACS reagent, ≥99.5%
Sigma-Aldrich
Ameisensäure, puriss. p.a., ACS reagent, reag. Ph. Eur., ≥98%
Sigma-Aldrich
Natriumcarbonat, ACS reagent, anhydrous, ≥99.5%, powder or granules
Sigma-Aldrich
Acetonitril, for HPLC, for UV, ≥99.9% (GC)
Sigma-Aldrich
Ammoniumacetat, ≥99.99% trace metals basis
Sigma-Aldrich
Acetonitril, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Methanol, suitable for HPLC, gradient grade, suitable as ACS-grade LC reagent, ≥99.9%
Sigma-Aldrich
Methanol, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.8% (GC)
Sigma-Aldrich
Methanol, anhydrous, 99.8%
Sigma-Aldrich
Methanol, Laboratory Reagent, ≥99.6%
Sigma-Aldrich
Ameisensäure, puriss., meets analytical specifications of DAC, FCC, 98.0-100%
Sigma-Aldrich
Natriumcarbonat, ACS reagent (primary standard), anhydrous, 99.95-100.05% dry basis
Supelco
Ammoniumacetat, LiChropur, eluent additive for LC-MS
Sigma-Aldrich
Ameisensäure, ACS reagent, ≥88%
Sigma-Aldrich
Natriumcarbonat, ReagentPlus®, ≥99.5%
Sigma-Aldrich
Ethylacetat, suitable for HPLC, ≥99.8%