Direkt zum Inhalt
Merck
  • Quality by Design approach to understand the physicochemical phenomena involved in controlled release of captopril SR matrix tablets.

Quality by Design approach to understand the physicochemical phenomena involved in controlled release of captopril SR matrix tablets.

International journal of pharmaceutics (2014-12-03)
J Saurí, D Millán, J M Suñé-Negre, H Colom, J R Ticó, M Miñarro, P Pérez-Lozano, E García-Montoya
ZUSAMMENFASSUNG

The aim of this study is to obtain swelling controlled release matrix tablets of captopril using the Quality by Design methodology (ICH Q8) and to know the transport mechanisms involved in captopril release. To obtain the area of knowledge, the design of experiments studying the effect of two components (HPMC K15M and ethylcellulose) at different levels has been applied, with the captopril dissolution profile as the product's most important critical quality attribute (CQA). Different dissolution profiles have been obtained with the design of experiments performed, which is a key factor in the development of controlled release matrix tablets. Kinetic analysis according to the equations of Higuchi and Korsmeyer-Peppas demonstrates that the release mechanism is a mechanism of erosion when the whole percentage of the polymer is ethylcellulose, and a diffusion mechanism when the whole percentage of the polymer is HPMC K15M. The physico-chemical characteristics of the gel layer determine the release rate of captopril. The thickness of the gel layer, the porosity which is formed in the matrix upon contact with water, pore size, the swelling rate, the erosion rate of the matrix, and the physico-chemical characteristics of captopril, are factors related to the kinetic equations described and that allow us to predict the release mechanism of captopril. A new relationship of the kinetic equations governing the in vitro behavior with the physical characteristics of the gel layer of the different formulations has been established. This study shows that the size of water-filled pores and the degree of crosslinking between the chains of HPMC K15M of the matrix are related to the exponent n of the Korsmeyer-Peppas equation and the type of transport of the captopril from within the matrix to the dissolution medium, that is, if the transport is only through water-filled pores, or if a combination of diffusion occurs through water-filled pores with a transport through continuous polymeric networks.

MATERIALIEN
Produktnummer
Marke
Produktbeschreibung

Sigma-Aldrich
L-Ascorbinsäure, powder, suitable for cell culture, γ-irradiated
Sigma-Aldrich
L-Ascorbinsäure, BioXtra, ≥99.0%, crystalline
Sigma-Aldrich
L-Ascorbinsäure, suitable for cell culture, suitable for plant cell culture, ≥98%
Sigma-Aldrich
L-Ascorbinsäure, reagent grade, crystalline
USP
Ascorbinsäure, United States Pharmacopeia (USP) Reference Standard
Supelco
L-Ascorbinsäure, analytical standard
Sigma-Aldrich
L-Ascorbinsäure, reagent grade
Sigma-Aldrich
L-Ascorbinsäure, 99%
Sigma-Aldrich
L-Ascorbinsäure, meets USP testing specifications
Supelco
Ascorbinsäure, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
L-Ascorbinsäure, FCC, FG
Sigma-Aldrich
Captopril, ≥98% (HPLC), powder
Sigma-Aldrich
L-Ascorbinsäure, ACS reagent, ≥99%
Sigma-Aldrich
L-Ascorbinsäure, BioUltra, ≥99.5% (RT)
Sigma-Aldrich
L-Ascorbinsäure, puriss. p.a., ACS reagent, reag. ISO, Ph. Eur., 99.7-100.5% (oxidimetric)
Ascorbinsäure, European Pharmacopoeia (EP) Reference Standard
Sigma-Aldrich
L-Ascorbinsäure, tested according to Ph. Eur.
USP
Captopril, United States Pharmacopeia (USP) Reference Standard
Supelco
Captopril, Pharmaceutical Secondary Standard; Certified Reference Material
Supelco
L-Ascorbinsäure, certified reference material, TraceCERT®, Manufactured by: Sigma-Aldrich Production GmbH, Switzerland
Sigma-Aldrich
L-Ascorbinsäure, puriss. p.a., ≥99.0% (RT)
Sigma-Aldrich
Captopril, meets USP testing specifications
Captopril, European Pharmacopoeia (EP) Reference Standard
Captopril für die Systemeignung, European Pharmacopoeia (EP) Reference Standard