Direkt zum Inhalt
Merck

G2025

Sigma-Aldrich

Glycerin

BioReagent, suitable for cell culture, suitable for insect cell culture, suitable for electrophoresis, ≥99% (GC)

Synonym(e):

1,2,3-Propantriol, Glycerin

Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise

Größe auswählen

100 ML
CHF 143.00
1 L
CHF 238.00
500 ML
CHF 341.00

CHF 143.00


Voraussichtliches Versanddatum26. März 2025


Bulk-Bestellung anfordern

Größe auswählen

Ansicht ändern
100 ML
CHF 143.00
1 L
CHF 238.00
500 ML
CHF 341.00

About This Item

Lineare Formel:
HOCH2CH(OH)CH2OH
CAS-Nummer:
Molekulargewicht:
92.09
Beilstein:
635685
EG-Nummer:
MDL-Nummer:
UNSPSC-Code:
50161901
PubChem Substanz-ID:
NACRES:
NA.21
Assay:
≥99% (GC)
Methode(n):
cell culture | insect: suitable
cell culture | mammalian: suitable
bp:
182 °C/20 mmHg (lit.)
Dampfdruck:
<1 mmHg ( 20 °C)

CHF 143.00


Voraussichtliches Versanddatum26. März 2025


Bulk-Bestellung anfordern

Dampfdichte

3.1 (vs air)

Qualitätsniveau

Dampfdruck

<1 mmHg ( 20 °C)

Produktlinie

BioReagent

Assay

≥99% (GC)

Form

viscous liquid

Selbstzündungstemp.

698 °F

Methode(n)

cell culture | insect: suitable
cell culture | mammalian: suitable

Verunreinigungen

≤0.005% Chlorinated compounds
≤0.005% Sulfate (SO4)

Brechungsindex

n20/D 1.474 (lit.)

pH-Wert

5.5-8

bp

182 °C/20 mmHg (lit.)

mp (Schmelzpunkt)

20 °C (lit.)

Dichte

1.25 g/mL (lit.)

Eignung

suitable for electrophoresis

SMILES String

OCC(O)CO

InChI

1S/C3H8O3/c4-1-3(6)2-5/h3-6H,1-2H2

InChIKey

PEDCQBHIVMGVHV-UHFFFAOYSA-N

Suchen Sie nach ähnlichen Produkten? Aufrufen Leitfaden zum Produktvergleich

Allgemeine Beschreibung

Glycerin, eine süß schmeckende Flüssigkeit, ist geruchlos, farblos und von Natur aus viskos. Es kann natürlich sowie aus petrochemischen Rohstoffen gewonnen werden. Glycerin ist für verschiedenste Anwendungen geeignet und ist eine der wertvollsten und vielseitigsten natürlichen chemischen Substanzen. Es kann als Weichmacher, Lösungsmittel, Süßungsmittel sowie in pharmazeutischen Formulierungen, Kosmetika, Lebensmitteln und Toilettenartikeln verwendet werden. Es ist sehr stabil und kann leicht bei normalen Temperaturen aufbewahrt werden; es ist außerdem nicht reizend und hat keine nachteiligen Auswirkungen auf die Umwelt.

Anwendung

Glycerin wird bei der Polyacrylamid-Gelelektrophorese sowohl zur Probenvorbereitung als auch zur Gelbildung verwendet. Glycerin (5–10 %) erhöht die Dichte einer Probe, sodass sie zum Boden der Kavität einer Probenplatte sinkt. Glycerin wird auch als Hilfsmittel beim Gießen von Gradientengelen, zur Stabilisierung von Proteinen und als Komponente von Lagerpuffern verwendet.

Biochem./physiol. Wirkung

Glycerin ist von Natur aus hygroskopisch und aufgrund seiner drei hydrophilen alkoholischen Hydroxylgruppen wasserlöslich. Es kann sowohl inter- als auch intramolekulare Wasserstoffbrückenbindungen bilden und ist daher ein sehr flexibles Molekül. Die physiologische Wirkung von Glycerin beruht auf zellvermittelter Immunität, erhöhter IgG-Produktion und erhöhter Histaminfreisetzung.
Glycerin wird verwendet als:
  • Zusatzstoff bei der Zellkultivierung von Mycobacterium tuberculosis und Mycobacterium avium.
  • Brennstoff bei der Herstellung einer enzymatischen Bio-Brennstoffzelle.
  • flüssige Kompositmatrix mit 4-HCCA und 3-Aminochinolin für die Analyse von neutralen und sauren Glycanen.
  • Matrix für Fast Atom Bombardment MS.
  • Kann als flüssige Matrix für Quantifizierungsstudien mittels MALDI (Matrix-unterstützte Laserdesorptions/Ionisations-Massenspektrometrie) eingesetzt werden.

Sie haben nicht das passende Produkt gefunden?  

Probieren Sie unser Produkt-Auswahlhilfe. aus.

Lagerklassenschlüssel

10 - Combustible liquids

WGK

WGK 1

Flammpunkt (°F)

390.2 °F - Pensky-Martens closed cup

Flammpunkt (°C)

199 °C - Pensky-Martens closed cup

Persönliche Schutzausrüstung

Eyeshields, Gloves


Hier finden Sie alle aktuellen Versionen:

Analysenzertifikate (COA)

Lot/Batch Number

Die passende Version wird nicht angezeigt?

Wenn Sie eine bestimmte Version benötigen, können Sie anhand der Lot- oder Chargennummer nach einem spezifischen Zertifikat suchen.

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

Kunden haben sich ebenfalls angesehen

Shelley L Forrest et al.
The Journal of comparative neurology, 522(17), 3900-3927 (2014-07-22)
Artemin is a member of the glial cell line-derived neurotrophic factor (GDNF) family that has been strongly implicated in development and regeneration of autonomic nerves and modulation of nociception. Whereas other members of this family (GDNF and neurturin) primarily target
Benoît Ranchoux et al.
The American journal of pathology, 185(2), 356-371 (2014-12-17)
Pulmonary veno-occlusive disease (PVOD) is an uncommon form of pulmonary hypertension (PH) characterized by progressive obstruction of small pulmonary veins and a dismal prognosis. Limited case series have reported a possible association between different chemotherapeutic agents and PVOD. We evaluated
T W Chew et al.
Oncogene, 33(21), 2717-2727 (2013-07-03)
RAS and Rho small GTPases are key molecular switches that control cell dynamics, cell growth and tissue development through their distinct signaling pathways. Although much has been learnt about their individual functions in both cell and animal models, the physiological
Nazish Ahmed et al.
Tissue engineering. Part A, 20(15-16), 2224-2233 (2014-03-13)
One of the factors preventing clinical application of regenerative medicine to degenerative cartilage diseases is a suitable source of cells. Chondrocytes, the only cell type of cartilage, grown in vitro under culture conditions to expand cell numbers lose their phenotype
Dmitry Usoskin et al.
Nature neuroscience, 18(1), 145-153 (2014-11-25)
The primary sensory system requires the integrated function of multiple cell types, although its full complexity remains unclear. We used comprehensive transcriptome analysis of 622 single mouse neurons to classify them in an unbiased manner, independent of any a priori

Protokolle

Überblick über die Chemie von Polyacrylamidgelen und detaillierte Anweisungen für den Handguss von Polyacrylamidgelen mit den mPAGE® TurboMix Bis-Tris-Gelgießkits.

Simplify your SDS-PAGE gel preparation with our pre-mixed solutions and protocols to achieve precise protein separation.

Questions

1–9 of 9 Questions  
  1. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

  2. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf

      Helpful?

  3. What is the concentration of glycerol (e.g., Product No. G2025)?

    1 answer
    1. Based on a density of 1.261 g/mL for glycerol, and a molecular weight of 92.1 g/mol, the concentration of this liquid is 13.7 M.

      Helpful?

  4. What is the viscosity of glycerol?

    1 answer
    1. The viscosity of glycerol is 648 Centistokes at 20 Deg C (68 Deg F).

      Helpful?

  5. In what solvent is glycerol (e.g., Product No. G2025) most soluble?

    1 answer
    1. Glycerol is miscible with water and alcohol at all concentrations. See: The chemicals encyclopedia published by the Royal Society of Chemistry, 12th ed., Entry# 4493.

      Helpful?

  6. Can I autoclave glycerol (e.g., Product No. G2025) before using it (for example) for cell culture?

    1 answer
    1. Glycerol can be autoclaved for 20 minutes, as is or in a solution, generally at approximately 50%.

      Helpful?

  7. Is Product No. G2025 a sterile glycerol product?

    1 answer
    1. Our quality specifications for this product include cell culture testing, but the product is not sterile as it is shipped.

      Helpful?

  8. What is the meaning of "Performance" in your specification sheet for Product No. G2025 (Glycerol)?

    1 answer
    1. The "Performance" test demonstrates that a cell freezing medium prepared using that product maintains the viability of mammalian cells after storing the cells for 5 to 7 days at -196 °C.

      Helpful?

  9. What is the Department of Transportation shipping information for this product?

    1 answer
    1. Transportation information can be found in Section 14 of the product's (M)SDS.To access the shipping information for this material, use the link on the product detail page for the product.

      Helpful?

Reviews

No rating value

Active Filters

Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..

Setzen Sie sich mit dem technischen Dienst in Verbindung.