Direkt zum Inhalt
Merck

A5949

Sigma-Aldrich

L-Arginin -monohydrochlorid

BioXtra, pH 5.0-7.0 (20 °C, 1 M in H2O), >99% (TLC)

Synonym(e):

(S)-(+)-2-Amino-5-[(aminoiminomethyl)amino]-pentansäure -monohydrochlorid, (S)-(+)-Arginin -hydrochlorid

Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise


About This Item

Empirische Formel (Hill-System):
C6H14N4O2 · HCl
CAS-Nummer:
Molekulargewicht:
210.66
Beilstein:
3631658
EG-Nummer:
MDL-Nummer:
UNSPSC-Code:
12352209

Produktlinie

BioXtra

Assay

>99% (TLC)

Verunreinigungen

<0.0005% Phosphorus (P)
<0.1% Insoluble matter

Glührückstand

<0.1%

pH-Wert

5.0-7.0 (20 °C, 1 M in H2O)

Löslichkeit

H2O: 1 M at 20 °C, clear, colorless

Anionenspuren

sulfate (SO42-): <0.05%

Kationenspuren

Al: <0.0005%
Ca: <0.0005%
Cu: <0.0005%
Fe: <0.0005%
K: <0.005%
Mg: <0.0005%
NH4+: <0.05%
Na: <0.005%
Pb: <0.001%
Zn: <0.0005%

Absorption

<0.1 at 280 in H2O at 1 M
<0.2 at 260 in H2O at 1 M

SMILES String

Cl[H].N[C@@H](CCCNC(N)=N)C(O)=O

InChI

1S/C6H14N4O2.ClH/c7-4(5(11)12)2-1-3-10-6(8)9;/h4H,1-3,7H2,(H,11,12)(H4,8,9,10);1H/t4-;/m0./s1

InChIKey

KWTQSFXGGICVPE-WCCKRBBISA-N

Suchen Sie nach ähnlichen Produkten? Aufrufen Leitfaden zum Produktvergleich

Biochem./physiol. Wirkung

Substrat der Stickstoffmonoxid-Synthase, das in Citrullin und Stickstoffmonoxid (NO) umgewandelt wird. Induziert Insulin-Freisetzung durch einen Stickoxid-abhängigen Mechanismus.

Lagerklassenschlüssel

13 - Non Combustible Solids

WGK

WGK 1

Flammpunkt (°F)

Not applicable

Flammpunkt (°C)

Not applicable

Persönliche Schutzausrüstung

dust mask type N95 (US), Eyeshields, Gloves


Analysenzertifikate (COA)

Suchen Sie nach Analysenzertifikate (COA), indem Sie die Lot-/Chargennummer des Produkts eingeben. Lot- und Chargennummern sind auf dem Produktetikett hinter den Wörtern ‘Lot’ oder ‘Batch’ (Lot oder Charge) zu finden.

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

Carolina Di Somma et al.
Endocrine, 49(2), 492-502 (2014-11-10)
The aim of the study is to clarify the relationship between adipose tissue dysfunction, metabolic profile and growth hormone (GH)/insulin-like growth factor (IGF)-I secretion in healthy adult subjects. We investigated the metabolic profile in a cohort of 231 consecutive healthy
C B Christiansen et al.
Hormone and metabolic research = Hormon- und Stoffwechselforschung = Hormones et metabolisme, 47(7), 537-543 (2015-01-21)
TLQP-21 is a VGF-derived neuropeptide proposed to be involved in regulation of metabolism. More specifically it has been suggested that TLQP-21 has the ability to enhance glucose stimulated insulin secretion, making it a candidate for treatment of patients with type
Jenna Gallie et al.
PLoS biology, 13(3), e1002109-e1002109 (2015-03-13)
Phenotype switching is commonly observed in nature. This prevalence has allowed the elucidation of a number of underlying molecular mechanisms. However, little is known about how phenotypic switches arise and function in their early evolutionary stages. The first opportunity to
N E Paul et al.
Bio-medical materials and engineering, 25(3), 289-297 (2015-09-26)
Adipose tissue engineering is a promising solution for the reconstruction of soft tissue defects. An insufficient neovascularisation within the scaffolds that leads to necrosis and tissue loss is still a major shortcoming of current tissue engineering attempts. Biomaterials, which release
Nivaldo Ribeiro Villela et al.
Journal of translational medicine, 12, 232-232 (2014-08-26)
Relative hypovolemia is frequently found in early stages of severe sepsis and septic shock and prompt and aggressive fluid therapy has become standard of care improving tissue perfusion and patient outcome. This paper investigates the role of the nitric oxide

Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..

Setzen Sie sich mit dem technischen Dienst in Verbindung.