Direkt zum Inhalt
Merck

PHR1067

Supelco

Carbamazepin

Pharmaceutical Secondary Standard; Certified Reference Material

Synonym(e):

5H-Dibenz[b,f]azepin-5-carboxamid

Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise


About This Item

Empirische Formel (Hill-System):
C15H12N2O
CAS-Nummer:
Molekulargewicht:
236.27
EG-Nummer:
MDL-Nummer:
UNSPSC-Code:
41116107
PubChem Substanz-ID:
NACRES:
NA.24

Qualität

certified reference material
pharmaceutical secondary standard

Qualitätsniveau

Agentur

traceable to BP 974
traceable to Ph. Eur. C0450000
traceable to USP 1093001

API-Familie

carbamazepine

Analysenzertifikat (CofA)

current certificate can be downloaded

Methode(n)

HPLC: suitable
gas chromatography (GC): suitable

mp (Schmelzpunkt)

191-192 °C (lit.)

Anwendung(en)

pharmaceutical (small molecule)

Format

neat

Lagertemp.

2-30°C

SMILES String

NC(=O)N1c2ccccc2C=Cc3ccccc13

InChI

1S/C15H12N2O/c16-15(18)17-13-7-3-1-5-11(13)9-10-12-6-2-4-8-14(12)17/h1-10H,(H2,16,18)

InChIKey

FFGPTBGBLSHEPO-UHFFFAOYSA-N

Suchen Sie nach ähnlichen Produkten? Aufrufen Leitfaden zum Produktvergleich

Allgemeine Beschreibung

Certified pharmaceutical secondary standards for application in quality control provide pharma laboratories and manufacturers with a convenient and cost-effective alternative to in-house working standards.

Carbamazepine is a tricyclic lipophilic compound, with mild anticholinergic activity. It is widely used as an antiepileptic drug for the treatment of simple and complex partial tonic-clonic seizures.

Anwendung

Carbamazepine may be used as a pharmaceutical reference standard for the quantification of the analyte in pharmaceutical formulations using chromatography techniques.
These Secondary Standards are qualified as Certified Reference Materials. These are suitable for use in several analytical applications including but not limited to pharma release testing, pharma method development for qualitative and quantitative analyses, food and beverage quality control testing, and other calibration requirements.

Biochem./physiol. Wirkung

Antikonvulsivum; Ligand für die Benzodiazepin modulatorische Stelle am GABAA-Rezeptor; Natriumkanalinhibitor.

Hinweis zur Analyse

These secondary standards offer multi-traceability to the USP, EP (PhEur) and BP primary standards, where they are available.

Sonstige Hinweise

This Certified Reference Material (CRM) is produced and certified in accordance with ISO 17034 and ISO/IEC 17025. All information regarding the use of this CRM can be found on the certificate of analysis.

Fußnote

To see an example of a Certificate of Analysis for this material enter LRAA6055 in the slot below. This is an example certificate only and may not be the lot that you receive.

Empfohlene Produkte

Find a digital Reference Material for this product available on our online platform ChemisTwin® for NMR. You can use this digital equivalent on ChemisTwin® for your sample identity confirmation and compound quantification (with digital external standard). An NMR spectrum of this substance can be viewed and an online comparison against your sample can be performed with a few mouseclicks. Learn more here and start your free trial.

Ähnliches Produkt

Piktogramme

Health hazardExclamation mark

Signalwort

Danger

Gefahreneinstufungen

Acute Tox. 4 Oral - Repr. 1A - Resp. Sens. 1 - Skin Sens. 1A - STOT SE 3

Zielorgane

Central nervous system

Lagerklassenschlüssel

6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects

WGK

WGK 2

Flammpunkt (°F)

Not applicable

Flammpunkt (°C)

Not applicable


Choose from one of the most recent versions:

Analysenzertifikate (COA)

Lot/Batch Number

Don't see the Right Version?

If you require a particular version, you can look up a specific certificate by the Lot or Batch number.

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

Kunden haben sich ebenfalls angesehen

An ultra-sensitive LC method for the simultaneous determination of paracetamol, carbamazepine, losartan and ciprofloxacin in bulk drug, pharmaceutical formulation and human serum by programming the detector
Sultana N, et al.
American Journal of Analytical Chemistry, 04(1), 24-24 (2013)
Development and validation of an HPLC-UV method for the quantification of carbamazepine in rabbit plasma
Mowafy AH, et al.
Saudi Pharmaceutical Journal : SPJ : The Official Publication of the Saudi Pharmaceutical Society, 20(1), 29-34 (2012)
A rapid LC method for the identification and determination of CNS drugs in pharmaceutical formulations
Raggi.A.M, et al.
Journal of Pharmaceutical and Biomedical Analysis, 23(1), 161-167 (2000)
Pharmacology for the Primary Care Provider (2008)
U Amstutz et al.
Clinical pharmacology and therapeutics, 94(1), 142-149 (2013-04-17)
The occurrence of hypersensitivity reactions including rare but life-threatening Stevens-Johnson syndrome (SJS) and drug-induced hypersensitivity syndrome (HSS) limits the use of the anticonvulsant carbamazepine (CBZ). Human leukocyte antigen-B (HLA)-B 15:02 and HLA-A 31:01 have been identified as predictive genetic markers

Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..

Setzen Sie sich mit dem technischen Dienst in Verbindung.