Direkt zum Inhalt
Merck

MAIPN4550

Millipore

Multiscreen® 96 well Plate, hydrophobic PVDF membrane

pore size 0.45 μm, non-sterile

Synonym(e):

Hydrophobic 96-Well Plate, PVDF 96-Well Plate, PVDF Membrane Plate

Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise


About This Item

UNSPSC-Code:
41104923
eCl@ss:
32039006
NACRES:
NB.22

Materialien

PVDF membrane (hydrophobic)
acrylic
flat bottom wells

Qualitätsniveau

Beschreibung

Non-sterile, clear 96-well filter plate with 0.45 um pore size Hydrophobic PVDF membrane for Avidin-biotin Linkages, DNA-binding Proteins, Protein Binding & PAMPA. Comes in a pack of 50.

Sterilität

non-sterile

Produktlinie

MultiScreen®

Leistungsmerkmale

hydrophobic
lid

Hersteller/Markenname

MultiScreen®

Parameter

50-250 μL sample volume (per well)

Methode(n)

parallel artificial membrane permeation assay (PAMPA): suitable

Filtrationsfläche

0.3 cm2

Plattengröße

96 wells

Maximales Well-Volumen

300 μL

Arbeitsvolumen

50-250 μL

Matrix

Immobilon®-P

Porengröße

0.45 μm pore size

Bindungsart

high binding surface

Versandbedingung

ambient

Anwendung

MultiScreen®-IP Filterplatte, 0,45 μm, transparent, nicht steril, wird für Folgendes verwendet:
  • als künstliche Membranstütze und Auffangplatte in Parallel Artificial Membrane Permeation Assays (PAMPA) zur Bestimmung der Permeabilität von Oximen
  • in Enzyme-Linked ImmunoSpot Assays (ELISpot)
  • in KLH(Schlitzschnecken-Hämocyanin)-spezifischen ELISpots zum Identifizieren von Antigen(Ag)-spezifischen Zellen

Rechtliche Hinweise

Immobilon is a registered trademark of Merck KGaA, Darmstadt, Germany
MULTISCREEN is a registered trademark of Merck KGaA, Darmstadt, Germany

Sie haben nicht das passende Produkt gefunden?  

Probieren Sie unser Produkt-Auswahlhilfe. aus.


Analysenzertifikate (COA)

Suchen Sie nach Analysenzertifikate (COA), indem Sie die Lot-/Chargennummer des Produkts eingeben. Lot- und Chargennummern sind auf dem Produktetikett hinter den Wörtern ‘Lot’ oder ‘Batch’ (Lot oder Charge) zu finden.

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

A C Belkina et al.
Journal of dental research, 99(7), 855-862 (2020-03-19)
Periodontitis (PD) is a common source of uncontrolled inflammation in obesity-associated type 2 diabetes (T2D). PD apparently fuels the inflammation of T2D and associates with poor glycemic control and increased T2D morbidity. New therapeutics are critically needed to counter the
Claudia Giesecke et al.
Journal of immunology (Baltimore, Md. : 1950), 200(12), 3981-3992 (2018-05-08)
There are currently limited insights into the progression of human primary humoral immunity despite numerous studies in experimental models. In this study, we analyzed a primary and related secondary parenteral keyhole limpet hemocyanin (KLH) immunization in five human adults. The
Hee Chun Jeong et al.
Bioorganic & medicinal chemistry, 17(17), 6213-6217 (2009-08-12)
A series of fluorinated oxime compounds was designed and synthesized in order to probe the effect of fluorine substitution on reactivation of inhibited acetylcholinesterase (AChE) by organophosphorus agents. Permeability measurements, using the Parallel Artificial Membrane Permeation Assays (PAMPA) method, were

Artikel

This is a white paper on the Evaluation of the reproducibility of Parallel Artificial Membrane Permeation Assays (PAMPA) using MultiScreen® Filter Plates.

This is a protocol for a Membrane Integrity test for Lipid-PAMPA Artificial Membranes

Combining solubility & PAMPA assays streamlines drug permeability testing.

Protokolle

Assays that predict passive absorption of orally administered drugs have become increasingly important in the drug discovery process. As previously described by Faller and Kansy such assays provide rapid, low cost and automation friendly methods to measure a compound’s passive permeability.

Guidelines for various bioassays on the MultiScreen system, which makes it possible to carry out an assay from sample incubation to scintillation counting in a 96-well plate.

Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..

Setzen Sie sich mit dem technischen Dienst in Verbindung.