Millipore

Millipore Express® SHC, Opticap®-XLT-Kapsel

Opticap® XLT 30, cartridge L 34.3 in. (87.2 cm), filter diam. 2.7 in. (6.9 cm)

Synonym(e):

Gamma Opticap® XLT HBP 30 Express SHC TC/TC

Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise


About This Item

UNSPSC-Code:
23151806

Materialien

polyethersulfone filter (PES)
polyethylene support
polypropylene housing (PP)
silicon seal

Qualitätsniveau

Einhaltung gesetzlicher Vorschriften

meets FDA CFR 210.3 (b) (6) (all component materials)

Sterilität

irradiated
non-sterile

Kompatibilität mit Sterilisationsverfahren

gamma compatible

Produktlinie

Opticap® XLT 30

Leistungsmerkmale

hydrophilic

Parameter

1.0 bar max. inlet pressure (15 psi) at 80 °C
1000 mbar max. differential pressure (15 psi) at 80 °C
2.75 bar max. inlet pressure (40 psi) at 60 °C
25 °C max. inlet temp.
5.5 bar max. inlet pressure (80 psi) at 25 °C
5500 mbar max. differential pressure (80 psi) at 25 °C
6.9 bar max. inlet pressure (100 psi) at 25 °C
76 L/min flow rate at 69 mbar (1 psi) and 23 °C
80 psig max. inlet pressure

Methode(n)

sterile filtration: suitable

Breite

7.8 in.

cartridge L

34.3 in. (87.2 cm)

device size

30 in. (75 cm)

Filterdurchm.

2.7 in. (6.9 cm)

Filtrationsfläche

1.62 m2

Verunreinigungen

≤0.25 EU/mL bacterial endotoxins (LAL test, aqueous extraction)

Matrix

Millipore Express® SHC

pore size

0.5/0.2 μm pore size

Blasenpunkt

≥4000 mbar (≥70 psig), air with water

Fitting

1/4 in. fitting (vent/drain hose barb with double O-ring seal)
(38 mm (1 1/2 in.) Sanitary Flange Inlet and Outlet)

Suchen Sie nach ähnlichen Produkten? Aufrufen Leitfaden zum Produktvergleich

Allgemeine Beschreibung

Cartidge Type: Liquid

Device Configuration: Capsule

Verpackung

Double Easy-Open bag

Angaben zur Herstellung

Sterilization Note:
3 autoclave cycles of 60 min @ 126 °C; capable of 45 kilogray (4.5 Megarad) gamma exposure; not in-line steam sterilizable
This product was manufactured with a Millipore Express® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).

Hinweis zur Analyse

TOC/Conductivity: After sterilization and a controlled water flush of 63 L, samples exhibited less than 500 ppb TOC per USP <643> and less than 1.3 μS/cm per USP <645> at 25 °C.

Sonstige Hinweise

Directions for Use:
  • Organism Retention: Microorganism
  • Mode of Action: Filtration (size exclusion)
  • Application: BioProcessing
  • Intended Use: Reduction or removal of microorganism/bioburden
  • Instructions for Use: Please refer to wetting instructions of Filters with Millipore Express® Membrane use guide
  • Storage Statement: Please refer to Filters with Millipore Express® Membrane user guide
  • Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations

These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.

Rechtliche Hinweise

MILLIPORE EXPRESS is a registered trademark of Merck KGaA, Darmstadt, Germany
OPTICAP is a registered trademark of Merck KGaA, Darmstadt, Germany

Not finding the right product?  

Try our Produkt-Auswahlhilfe.


Analysenzertifikate (COA)

Suchen Sie nach Analysenzertifikate (COA), indem Sie die Lot-/Chargennummer des Produkts eingeben. Lot- und Chargennummern sind auf dem Produktetikett hinter den Wörtern ‘Lot’ oder ‘Batch’ (Lot oder Charge) zu finden.

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..

Setzen Sie sich mit dem technischen Dienst in Verbindung.