Direkt zum Inhalt
Merck
Alle Fotos(1)

Dokumente

234401

Sigma-Aldrich

Complement C1q-Depleted Serum, Human

Synonym(e):

C1q-Depleted Serum, Human Complement Serum

Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise


About This Item

UNSPSC-Code:
12352202
NACRES:
NA.25

Form

solution

Qualitätsniveau

Enthält nicht

preservative

Hersteller/Markenname

Calbiochem®

Lagerbedingungen

OK to freeze
avoid repeated freeze/thaw cycles

Verunreinigungen

C1q, none detected (Ouchterlony using various dilutions of goat anti-human C1q antiserum.)

Farbe

clear amber

Versandbedingung

dry ice

Lagertemp.

−70°C

Allgemeine Beschreibung

Human serum that has been depleted of C1q complement component.
Human serum that has been depleted of C1q complement component. C1q-depleted human serum, sterile filtered through a 0.22 µm filter. This product has the following specifications:

Verpackung

Please refer to vial label for lot-specific concentration.

Warnhinweis

Toxicity: Standard Handling (A)

Einheitendefinition

Classical Pathway Activity: One C1qH50 unit measured by classical pathway activation is defined as the amount of C1q required to yield 50% lysis of 3 x 10⁷ EA when incubated in the presence of the recommended volume of C1q-Dpl for 30 min at 37°C in a total reaction volume of 500 µl GVB++.CH50 Functional Activity upon Reconstitution: One CH50 unit is defined as the input of C1q-Dpl, reconstituted with C1q, or NHS Complement Standard yielding 50% lysis of 1 x 10⁸ EA when incubated for 60 min at 37°C in a total reaction volume of 1.5 ml GVB++.Alternative Pathway Activity: One unit of whole alternative pathway activity (APH50) is defined as the input of C1q-Dpl or NHS Complement Standard yielding 50% lysis of 1.5 x 10⁷ rabbit erythrocytes when incubated for 30 min at 37°C in a total reaction volume of 75 ml GVB° containing a final Mg-EGTA concentration of 13.3 mM.

Physikalische Form

In PBS, ≤0.1% sodium azide, pH 7.4.

Angaben zur Herstellung

Prepared from serum that has been shown by certified tests to be negative for HBsAg and for antibodies to HCV, HIV-I, and HIV-II.

Rekonstituierung

Following initial thaw, aliquot and freeze (-70°C).

Sonstige Hinweise

No C1q detected by Ouchterlony using various dilutions of goat anti-human C1q antiserum. The following information will vary from lot to lot and can be found on the certificate of analysis:



CLASSICAL PATHWAY ACTIVITY: One C1qH50 unit measured by classical pathway activation is defined as the amount of C1q required to yield 50% lysis of 3 x 107 EA when incubated in the presence of the recommended volume of C1q-Dpl for 30 minutes at 37°C in a total reaction volume of 500 μl GVB++.

• Recommended volume of C1q-Dpl serum per assay

• C1qH50 units/mg purified C1q at the recommended input of C1q-Dpl

• Input of purified C1q to yield 1 C1qH50:

• C1qH50 units/ml NHS Complement standard at the recommended input of C1q-Dpl

• Input of C1q in NHS Complement standard to yield 1 C1qH50

• Ratio

• Background A412 EA blank reading at the recommended input of C1q-Dpl



CH50 FUNCTIONAL ACTIVITY UPON RECONSTITUTION: One CH50 unit is defined as the input of C1q-Dpl, reconstituted with C1q, or NHS Complement Standard yielding 50% lysis of 1 x 108 EA when incubated for 60 minutes at 37°C in a total reaction volume of 1.5 ml GVB++.

• CH50/ml NHS Standard

• CH50/ml C1q-Dpl reconstituted with 100 μg C1q/ml:

• Ratio



ALTERNATIVE PATHWAY ACTIVITY: One unit of whole alternative pathway activity (APH50) is defined as the input of C1q-Dpl or NHS Complement Standard yielding 50% lysis of 1.5 x 107 rabbit erythrocytes when incubated for 30 minutes at 37°C in a total reaction volume of 75 ml GVB° containing a final Mg-EGTA concentration of 13.3 mM.

• APH50/ml NHS Standard

• Input of NHS Standard to yield 1 APH50

• APH50/ml C1q-Dpl

• Input of C1q-Dpl to yield 1 APH50

• AP Ratio

Rechtliche Hinweise

CALBIOCHEM is a registered trademark of Merck KGaA, Darmstadt, Germany

Lagerklassenschlüssel

12 - Non Combustible Liquids

WGK

nwg

Flammpunkt (°F)

Not applicable

Flammpunkt (°C)

Not applicable


Analysenzertifikate (COA)

Suchen Sie nach Analysenzertifikate (COA), indem Sie die Lot-/Chargennummer des Produkts eingeben. Lot- und Chargennummern sind auf dem Produktetikett hinter den Wörtern ‘Lot’ oder ‘Batch’ (Lot oder Charge) zu finden.

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..

Setzen Sie sich mit dem technischen Dienst in Verbindung.