1.05548
HPTLC aluminum sheets, Silica gel 60 F₂₅₄
pkg of 25 sheets, sheet L × W 20 cm × 20 cm, aluminum support
Synonyme(s) :
HPTLC F₂₅₄ Silica Gel Plates
About This Item
Produits recommandés
Matériaux
aluminum support
silica gel 60 matrix
Niveau de qualité
Caractéristiques
binder Organic Polymer
fluorescent indicator
Conditionnement
pkg of 25 sheets
Technique(s)
thin layer chromatography (TLC): suitable
Épaisseur de la couche
200 μm
Feuille, L × l
20 cm × 20 cm
Taille des particules
5-6 μm
Dimension de pores
60 Å medium pore diameter
Température de stockage
2-30°C
Description générale
Application
- Novel Validated HPTLC Method for the Analysis of Two Binary Mixtures Containing Tamsulosin Hydrochloride with Antimuscarinic Agents.: This study presents a novel HPTLC method using aluminum sheets and Silica gel 60 F₂₅₄ for analyzing binary mixtures of Tamsulosin Hydrochloride with antimuscarinic agents. This method ensures accurate and efficient separation of the components (El-Kimary et al., 2018).
- Development and Validation of a High-Performance Thin-Layer Chromatographic Method for the Simultaneous Determination of Two Binary Mixtures Containing Ketorolac Tromethamine with Phenylephrine Hydrochloride and with Febuxostat.: This research developed a validated HPTLC method on aluminum sheets coated with Silica gel 60 F₂₅₄ for simultaneous determination of Ketorolac Tromethamine with Phenylephrine Hydrochloride and with Febuxostat, showcasing high accuracy and precision (El Yazbi et al., 2016).
- HPTLC Determination of Three Gliptins in Binary Mixtures with Metformin.: The article demonstrates the use of HPTLC aluminum sheets with Silica gel 60 F₂₅₄ for determining three gliptins in binary mixtures with Metformin, emphasizing the method′s efficiency and reliability (El-Kimary et al., 2016).
- Validated HPLC and HPTLC methods for simultaneous determination of colchicine and khellin in pharmaceutical formulations.: This paper details validated HPTLC methods on aluminum sheets and Silica gel 60 F₂₅₄ for simultaneous determination of colchicine and khellin, providing a robust and accurate analytical approach (Hadad et al., 2013).
Liaison
Remarque sur l'analyse
Pore volume (N₂-isotherm): 0.74 - 0.84 ml/g
d 50 (laser diffraction, size distribution): 5 - 7 µm
Layer thickness: 150 - 200 µm
Deviation of layer thickness per plate: ≤ 30 µm
Chromatographic testings:
A) Colour test
hRf-values
- bleu vif organol, colour test, lipophile:
17 - 22
- Ceres Black G, colour test, lipophile: 38 - 43
- ceres Violet brn, colour test, lipophile: 58 - 64
separation number
- colourtest, lipophile:
≥ 10.0
B) Steroid test
hRf-values
- hydrocortisone, steroid test:
23 - 29
- Reichstein S, steroid test: 36 - 45
- methyltestosterone, steroid test: 43 - 52
separation number
- steroid test:
≥ 10.5
Typical value determined on a conditioned sheet
Eluent A) Toluene (45% rel.humidity)
Eluent B) Ethyl acetate/Toluene (95+5 v/v; 20% rel.humidity)
Certificats d'analyse (COA)
Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".
Déjà en possession de ce produit ?
Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.
Les clients ont également consulté
Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..
Contacter notre Service technique