D0405
Dialysis tubing, high retention seamless cellulose tubing
avg. flat width 23 mm (0.9 in.), MWCO 14000, 99.99% retention
Sinônimo(s):
Dialysis tubing
Faça loginpara ver os preços organizacionais e de contrato
About This Item
Produtos recomendados
diâmetro médio
15 mm , when full
largura média plana
23 mm (0.9 in.)
capacidade
~50 mL/ft
tamanho de poro
14000 MWCO, 99.99% retention
Procurando produtos similares? Visita Guia de comparação de produtos
Descrição geral
Retains >99% of cytochrome c (M.W. 12,400) in solution over a 10-hour period.
Embalagem
Supplied in rolls, dry
Qualidade
May contain glycerin and sulfur compounds in more than trace amounts; washing instructions are included.
Nota de preparo
Removal of glycerol included as a humectant can be accomplished by washing the tubing in running water for 3-4 hours. Removal of sulfur compounds can be accomplished by treating the tubing with a 0.3% (w/v) solution of sodium sulfide at 80°C for 1 minute. Wash with hot water (60°C) for 2 minutes, followed by acidification with a 0.2% (v/v) solution of sulfuric acid, then rinse with hot water to remove the acid. This tubing will retain most proteins of molecular weight 12,000 or greater.
Escolha uma das versões mais recentes:
Certificados de análise (COA)
Lamentamos, não temos COA para este produto disponíveis online no momento.
Se precisar de ajuda, entre em contato Atendimento ao cliente
Já possui este produto?
Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.
Os clientes também visualizaram
Pathogens (Basel, Switzerland), 9(12) (2020-12-03)
Vaccine efficacy requires the production of neutralising antibodies which offer protection against the native virus. The current gold standard for determining the presence of neutralising antibodies is the pseudovirion-based neutralisation assay (PBNA). PBNAs utilise pseudovirions (PsVs), structures which mimic native
Journal of microencapsulation, 31(5), 448-460 (2014-04-05)
The purpose of this study was to develop a water/oil microemulsion containing lidocaine hydrochloride (4%) and to compare its local anaesthetic efficacy with commercial products. A pseudoternary diagram (Km:1/1 or 1/2) was constructed using lecithin/ethanol/oil/water. The droplet size, viscosity and
Journal of immunological methods, 416, 157-166 (2014-12-02)
Recombinant antigens are increasingly applied to replace native antigens in serological tests. Surface antigen 1 (SAG1) is a highly immunogenic antigen and probably represents the most explored and used antigen of Toxoplasma gondii for development of serological test kits. The
Conteúdo relacionado
Dialysis Tubing
Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.
Entre em contato com a assistência técnica