Pular para o conteúdo
Merck
Todas as fotos(1)

Documentos Principais

537551

Sigma-Aldrich

Ethylene glycol butyl ether

≥99%

Sinônimo(s):

2-Butoxyethanol, Butyl glycol

Faça loginpara ver os preços organizacionais e de contrato


About This Item

Fórmula linear:
CH3(CH2)3OCH2CH2OH
Número CAS:
Peso molecular:
118.17
Beilstein:
1732511
Número CE:
Número MDL:
Código UNSPSC:
12352104
ID de substância PubChem:
NACRES:
NA.21
Preço e disponibilidade não estão disponíveis no momento.

densidade de vapor

4.1 (vs air)

pressão de vapor

<1 mmHg ( 20 °C)
10 mmHg ( 81 °C)

Ensaio

≥99%

Formulário

liquid

temperatura de autoignição

473 °F

Lim. expl.

10.6 %

Impurezas

≤0.10% (water)

índice de refração

n20/D 1.419 (lit.)

p.e.

169-172.5 °C (lit.)

pf

−75 °C (lit.)

solubilidade

water: soluble

densidade

0.902 g/mL at 25 °C (lit.)

cadeia de caracteres SMILES

CCCCOCCO

InChI

1S/C6H14O2/c1-2-3-5-8-6-4-7/h7H,2-6H2,1H3

chave InChI

POAOYUHQDCAZBD-UHFFFAOYSA-N

Procurando produtos similares? Visita Guia de comparação de produtos

Descrição geral

Ethylene glycol butyl ether (EGBE) is an ethylene oxide-based glycol ether solvent commonly used in the coatings industry. Its relative evaporation rate with respect to n-butyl acetate has been reported to be 0.07.[1] Its toxicity has been assessed.[2] The effect of EGBE as a thickening solvent during acrylic latex synthesis has been investigated.[3]

Pictogramas

Skull and crossbones

Palavra indicadora

Danger

Frases de perigo

Classificações de perigo

Acute Tox. 3 Inhalation - Acute Tox. 4 Oral - Eye Irrit. 2 - Skin Irrit. 2

Código de classe de armazenamento

6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects

Classe de risco de água (WGK)

WGK 1

Ponto de fulgor (°F)

152.6 °F - Pensky-Martens closed cup

Ponto de fulgor (°C)

67 °C - Pensky-Martens closed cup


Escolha uma das versões mais recentes:

Certificados de análise (COA)

Lot/Batch Number

Não está vendo a versão correta?

Se precisar de uma versão específica, você pode procurar um certificado específico pelo número do lote ou da remessa.

Já possui este produto?

Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.

Visite a Biblioteca de Documentos

Os clientes também visualizaram

A novel alkali and cosolvent thickening mechanism for latex.
He L, et al.
New. J. Chem., 39(11), 8984-8992 (2015)
R L Smith
Environmental health perspectives, 57, 1-4 (1984-08-01)
Ethylene oxide-based glycol ether and glycol ether ester solvents have been used in the coatings industry for the past fifty years. Because of their excellent performance properties (evaporation rate, blush resistance, flow-out and leveling properties, solubility for coating resins, solvent
Reproductive toxicology. Ethylene glycol monobutyl ether.
Environmental health perspectives, 105 Suppl 1, 217-218 (1997-02-01)
Ryszard Tokarczyk et al.
Journal of chromatography. A, 1217(44), 6964-6970 (2010-09-22)
A gas chromatography-mass spectrometry isotope dilution (GC-MS ID) method was developed and tested for the determination of 14 common glycol ethers in consumer products. Stable isotope labelled standards, 2-methoxyethanol-D(7) and 2-butoxyethanol-(13)C(2) (CDN isotopes) were employed to enhance the accuracy and
Matthew J Traynor et al.
Toxicology letters, 177(3), 151-155 (2008-03-04)
Glycol ethers are widely used in industrial and household applications because their chemical and physical properties make them versatile solvents, miscible with both water and organic media. Due to the ease with which the glycol ethers are absorbed through the

Questions

1–2 of 2 Questions  
  1. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf

      Helpful?

  2. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

Reviews

No rating value

Active Filters

Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.

Entre em contato com a assistência técnica