Pular para o conteúdo
Merck
Todas as fotos(2)

Documentos Principais

43216

Supelco

Dodecamethylcyclohexasiloxane

analytical standard

Sinônimo(s):

2,2,4,4,6,6,8,8,10,10,12,12-Dodecamethylcyclohexasiloxane

Faça loginpara ver os preços organizacionais e de contrato

Selecione um tamanho

25 MG
R$ 426,00

R$ 426,00


Disponível para enviar em04 de abril de 2025Detalhes


Solicite uma grande encomenda

Selecione um tamanho

Alterar visualização
25 MG
R$ 426,00

About This Item

Fórmula empírica (Notação de Hill):
C12H36O6Si6
Número CAS:
Peso molecular:
444.92
Número CE:
Número MDL:
Código UNSPSC:
77101502
ID de substância PubChem:
NACRES:
NA.24

R$ 426,00


Disponível para enviar em04 de abril de 2025Detalhes


Solicite uma grande encomenda

grau

analytical standard

Nível de qualidade

Ensaio

≥97.0% (GC)

prazo de validade

limited shelf life, expiry date on the label

técnica(s)

HPLC: suitable
gas chromatography (GC): suitable

aplicação(ões)

cleaning products
cosmetics
environmental
food and beverages
personal care

Formato

neat

cadeia de caracteres SMILES

[Si]1(O[Si](O[Si](O[Si](O[Si](O[Si](O1)(C)C)(C)C)(C)C)(C)C)(C)C)(C)C

InChI

1S/C12H36O6Si6/c1-19(2)13-20(3,4)15-22(7,8)17-24(11,12)18-23(9,10)16-21(5,6)14-19/h1-12H3

chave InChI

IUMSDRXLFWAGNT-UHFFFAOYSA-N

Procurando produtos similares? Visita Guia de comparação de produtos

Descrição geral

Dodecamethylcyclohexasiloxane belonging to the class of cyclic volatile methylsiloxanes is identified as a potent environmental contaminant, most prominently found in biota, biosolid samples, soil, sediment samples, wastewaters, etc.[1] These compounds are used as fragrance carriers or solvents in household products, personal care products, cleaning agents and as precursors in the manufacture of silicone polymers.[2]

Aplicação

Dodecamethylcyclohexasiloxane may be used as an analytical reference standard for the quantification of the analyte in the following:
  • Silicone emulsions using gas chromatography with flame ionization detection (GC-FID).[3]
  • Biota[2] and wastewater samples[1] using gas chromatography coupled to mass spectrometry (GC-MS).

Refer to the product′s Certificate of Analysis for more information on a suitable instrument technique. Contact Technical Service for further support.

Código de classe de armazenamento

10 - Combustible liquids

Classe de risco de água (WGK)

WGK 3

Ponto de fulgor (°F)

195.8 °F - closed cup

Ponto de fulgor (°C)

91 °C - closed cup


Escolha uma das versões mais recentes:

Certificados de análise (COA)

Lot/Batch Number

Não está vendo a versão correta?

Se precisar de uma versão específica, você pode procurar um certificado específico pelo número do lote ou da remessa.

Já possui este produto?

Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.

Visite a Biblioteca de Documentos

Os clientes também visualizaram

A practical gas chromatography flame ionization detection method for the determination of octamethylcyclotetrasiloxane, decamethylcyclopentasiloxane, and dodecamethylcyclohexasiloxane in silicone emulsions
Kierkegaard A, et al.
Analytical Chemistry, 82(22), 9573-9578 (2010)
Determination of cyclic and linear siloxanes in wastewater samples by ultrasound-assisted dispersive liquid?liquid microextraction followed by gas chromatography?mass spectrometry
Cortada C, et al.
Talanta, 120, 191-197 (2014)
A practical gas chromatography flame ionization detection method for the determination of octamethylcyclotetrasiloxane, decamethylcyclopentasiloxane, and dodecamethylcyclohexasiloxane in silicone emulsions
Brothers MH, et al.
Journal of Chromatography A, 144, 116-125 (2016)

Questions

1–2 of 2 Questions  
  1. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf

      Helpful?

  2. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

Reviews

No rating value

Active Filters

Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.

Entre em contato com a assistência técnica