Accéder au contenu
Merck
  • Determination of polyphenolic compounds in Cirsium palustre (L.) extracts by high performance liquid chromatography with chemiluminescence detection.

Determination of polyphenolic compounds in Cirsium palustre (L.) extracts by high performance liquid chromatography with chemiluminescence detection.

Talanta (2014-12-02)
Edyta Nalewajko-Sieliwoniuk, Julita Malejko, Monika Mozolewska, Elżbieta Wołyniec, Jolanta Nazaruk
RÉSUMÉ

The first method for the simultaneous determination of polyphenolic antioxidants in extracts from leaves of Cirsium palustre based on high performance liquid chromatography combined with flow injection chemiluminescence detection (HPLC-FI-CL) has been developed. The extracts were prepared by using methanol as extraction medium and two types of extraction methods (reflux and ultrasound assisted extraction). The post-column CL determination of polyphenols was based on their enhancing effect on the chemiluminescence intensity generated in manganese(IV)-hexametaphosphate-formaldehyde system in a phosphoric acid medium. Main antioxidants determined in C. palustre leaves were eriodictyol-7-O-glucoside, luteolin-7-O-glucoside and 6-hydroxyluteolin-7-O-glucoside belonging to flavonoids, and chlorogenic acid belonging to phenolic acids. Chromatographic separation was carried out on a C18 column with gradient elution by using a mobile phase containing 0.25% (v/v) phosphoric acid in water (solvent A) and 100% methanol (solvent B). Under the optimized conditions of chromatographic separation and CL detection the validation of the method was performed. The calibration curves showed good linearity in the concentration range from 0.5 to 40 µg mL(-1). The HPLC-FI-CL method was successfully applied to the determination of four polyphenolic compounds in methanolic extracts from leaves of C. palustre. The accuracy of the developed method was confirmed by the comparison of the results with those obtained by an HPLC-PDA method. The relative error of determination does not exceed 6.1%. However, the HPLC-FI-CL method is characterized by 40-65 times higher sensitivity compared to the HPLC-PDA method.

MATÉRIAUX
Référence du produit
Marque
Description du produit

Sigma-Aldrich
Acétonitrile, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Méthanol, suitable for HPLC, ≥99.9%
Sigma-Aldrich
Méthanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Acide acétique, glacial, ACS reagent, ≥99.7%
Sigma-Aldrich
Acétonitrile, HPLC Plus, ≥99.9%
Sigma-Aldrich
Hydroxyde de sodium, ACS reagent, ≥97.0%, pellets
Sigma-Aldrich
Acide acétique, glacial, ReagentPlus®, ≥99%
Sigma-Aldrich
Hydroxyde de sodium, reagent grade, ≥98%, pellets (anhydrous)
Sigma-Aldrich
Hydroxyde de sodium solution, 50% in H2O
Sigma-Aldrich
Méthanol, HPLC Plus, ≥99.9%
Sigma-Aldrich
Acétonitrile, ACS reagent, ≥99.5%
Sigma-Aldrich
Hydroxyde de sodium solution, BioUltra, for molecular biology, 10 M in H2O
Sigma-Aldrich
Acétonitrile, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Acide acétique, glacial, ≥99.99% trace metals basis
Sigma-Aldrich
Hydroxyde de sodium, BioXtra, ≥98% (acidimetric), pellets (anhydrous)
Sigma-Aldrich
Méthanol, suitable for HPLC, gradient grade, suitable as ACS-grade LC reagent, ≥99.9%
Sigma-Aldrich
Hydroxyde de sodium solution, 1.0 N, BioReagent, suitable for cell culture
Sigma-Aldrich
Acide acétique solution, suitable for HPLC
Sigma-Aldrich
Hydroxyde de sodium, puriss., meets analytical specification of Ph. Eur., BP, NF, E524, 98-100.5%, pellets
Sigma-Aldrich
Hydroxyde de sodium, reagent grade, 97%, powder
Sigma-Aldrich
Méthanol, Laboratory Reagent, ≥99.6%
Sigma-Aldrich
Manganese(IV) oxide, ReagentPlus®, ≥99%
Sigma-Aldrich
Hydroxyde de sodium, pellets, semiconductor grade, 99.99% trace metals basis
Sigma-Aldrich
Formate de sodium, ACS reagent, ≥99.0%
Sigma-Aldrich
Manganese(IV) oxide, activated, ~85%, <10 μm
Sigma-Aldrich
Acétonitrile, anhydrous, 99.8%
Sigma-Aldrich
Méthanol, Absolute - Acetone free
Sigma-Aldrich
Méthanol, ACS spectrophotometric grade, ≥99.9%
Sigma-Aldrich
Chlorogenic acid, ≥95% (titration)
Sigma-Aldrich
Méthanol, BioReagent, ≥99.93%