Direkt zum Inhalt
Merck
  • Determination of urinary levels of leukotriene B(4) using ad highly specific and sensitive methodology based on automatic MEPS combined with UHPLC-PDA analysis.

Determination of urinary levels of leukotriene B(4) using ad highly specific and sensitive methodology based on automatic MEPS combined with UHPLC-PDA analysis.

Talanta (2015-10-11)
Rosa Perestrelo, Catarina L Silva, José S Câmara
ZUSAMMENFASSUNG

Leukotriene B4 (LTB4) is a potent mediator of inflammation and plays a key function in the pathophysiology of chronic asthma. Detectable urinary levels of LTB4, arises from the activation of leukotriene pathways. In this study an ultra-fast, selective and sensitive analytical method based on semi-automatic microextraction by packed sorbents (MEPS) technique, using a new digitally controlled syringe (eVol®) combined with ultra-high pressure liquid chromatography (UHPLC), is proposed for the measurement of urinary LTB4 (U-LTB4) levels in a group of asthmatic patients (APs) and healthy controls (CTRL). Important parameters affecting MEPS performance, namely sorbent type, number of extraction cycles (extract-discard) and elution volume, were evaluated. The optimal experimental conditions among those investigated for the quantification of U-LTB4 in urine samples were as follows: porous graphitic carbon sorbent (PGC), 10 extractions cycle (10×250 μL of sample) and LTB4 elution with 100 μL of acetonitrile. The UHPLC optimum conditions resulted in a mobile phase consisting of 95% (v/v) of acid aqueous solution (v/v), and acetonitrile 5% (v/v); flow rate of 500 µL/min, and a column temperature of 37±0.1 °C. Under optimized conditions the proposed method exhibit good selectivity and sensitivity LOD (0.37 ng/mL) and LOQ (1.22 ng/mL). The recovery ranging from 86.4 to 101.1% for LTB4, with relative standard deviations (% RSD) no larger than 5%. In addition, the method also afforded good results in terms of linearity (r(2)>0.995) within the established concentration range, with a residual deviation for each calibration point below 6%, and intra- and inter-day repeatability in urine samples with RSD values lower than 4 and 5%, respectively. The application of the method to urine samples revealed a tendency towards the increased urinary LTB4 levels in APs (5.42±0.17 ng/mL) when compared to those of CTRL group (from ND to 1.9 ng/mL). Urinary measurement of LTB4 may be an interesting and non-invasive option to assess control of asthma.

MATERIALIEN
Produktnummer
Marke
Produktbeschreibung

Supelco
SPME-Faseranordnung Divinylbenzol/Carboxen/Polydimethylsiloxan (DVB/CAR/PDMS), needle size 24 ga, StableFlex
Supelco
SPME-Faseranordnung Divinylbenzol/Carboxen/Polydimethylsiloxan (DVB/CAR/PDMS), needle size 24 ga, for use with manual holder
Supelco
SPME-Faseranordnung Divinylbenzol/Carboxen/Polydimethylsiloxan (DVB/CAR/PDMS), needle size 23 ga, StableFlex, for use with autosampler
Supelco
SPME-Faseranordnung Divinylbenzol/Carboxen/Polydimethylsiloxan (DVB/CAR/PDMS), needle size 23 ga, StableFlex, for use with manual holder or autosampler, fiber L 2 cm
Supelco
SPME-Faseranordnung Divinylbenzol/Carboxen/Polydimethylsiloxan (DVB/CAR/PDMS), needle size 24 ga, StableFlex, for use with autosampler
Supelco
SPME-Faseranordnung Polydimethylsiloxan (PDMS), df 100 μm(PDMS, needle size 24 ga, for use with manual holder
Supelco
SPME-Faseranordnung Polydimethylsiloxan (PDMS), df 100 μm(PDMS, for use with autosampler, needle size 23 ga
Supelco
SPME-Faseranordnung Polydimethylsiloxan (PDMS), df 100 μm(PDMS, for use with autosampler, needle size 24 ga
Supelco
SPME-Faseranordnung Carboxen/Polydimethylsiloxan (CAR/PDMS), df 75 μm(CAR/PDMS, for use with manual holder, needle size 24 ga
Supelco
SPME-Faseranordnung Polydimethylsiloxan/Divinylbenzen (PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, StableFlex, for use with autosampler
Supelco
SPME-Faseranordnung Carboxen/Polydimethylsiloxan (CAR/PDMS), df 85 μm(CAR/PDMS, needle size 23 ga, StableFlex, for use with autosampler
Supelco
SPME-Faseranordnung Polydimethylsiloxan/Divinylbenzen (PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, for use with manual holder
Supelco
SPME-Faseranordnung Carboxen/Polydimethylsiloxan (CAR/PDMS), df 75 μm(CAR/PDMS, needle size 24 ga, for use with autosampler
Supelco
SPME-Faseranordnung Carboxen/Polydimethylsiloxan (CAR/PDMS), df 85 μm(CAR/PDMS, needle size 24 ga, StableFlex, for use with autosampler
Supelco
SPME-Faseranordnung Polyacrylat (PA), df 85 μm(PA, for use with autosampler, needle size 23 ga
Supelco
SPME-Faseranordnung Polydimethylsiloxan/Divinylbenzen (PDMS/DVB), df 65 μm(PDMS/DVB, needle size 23 ga, PDMS/DVB StableFlex, for use with autosampler
Supelco
SPME-Faseranordnung Polyacrylat (PA), df 85 μm(PA, for use with autosampler, needle size 24 ga
Supelco
SPME-Faseranordnung Carboxen/Polydimethylsiloxan (CAR/PDMS), df 85 μm(CAR/PDMS, needle size 24 ga, for use with manual holder, StableFlex fiber
Supelco
SPME-Faseranordnung Polydimethylsiloxan/Divinylbenzen (PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, StableFlex, for use with manual holder
Supelco
SPME-Faseranordnung Polydimethylsiloxan (PDMS), df 100 μm(PDMS, for use with manual holder, needle size 23 ga
Supelco
SPME-Faseranordnung Polydimethylsiloxan/Divinylbenzen (PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, for use with autosampler
Supelco
SPME-Faseranordnung Carboxen/Polydimethylsiloxan (CAR/PDMS), df 75 μm(CAR/PDMS, needle size 23 ga, for use with autosampler
Supelco
SPME StableFlex Methodenentwicklungs-Kit, for use with manual holder
Supelco
SPME-Faseranordnung, Carbowax-Polyethylenglycol (PEG)-Beschichtung, needle size 23 ga, df 60 μm(PEG, for use with autosampler
Supelco
SPME-Faseranordnung Polydimethylsiloxan/Divinylbenzen (PDMS/DVB), df 65 μm(PDMS/DVB, for use with autosampler, needle size 23 ga
Supelco
SPME-Faseranordnung Carboxen/Polydimethylsiloxan (CAR/PDMS), df 75 μm(CAR/PDMS, needle size 23 ga, for use with manual holder
Supelco
SPME StableFlex Methodenentwicklungs-Kit, needle size 23 ga, for use with autosampler
Supelco
SPME-Faseranordnung Polydimethylsiloxan/Divinylbenzen (PDMS/DVB), fused silica fiber, df 65 μm(PDMS/DVB, for use with manual holder, needle size 23 ga
Supelco
SPME-Fasersortiment-Kit 4, for use with manual holder, size 24 ga
Supelco
SPME-Faseranordnung Polyacrylat (PA), df 85 μm(PA, for use with manual holder, needle size 24 ga