Direkt zum Inhalt
Merck

MAK055

Sigma-Aldrich

AST-Aktivitäts-Assay-Kit

sufficient for 100 colorimetric tests

Synonym(e):

Aspartat-Aminotransferase-Aktivitäts-Assay-Kit, Glutamat-Oxalacetat-Transaminase-Aktivitäts-Assay-Kit, SGOT-Aktivitäts-Assay-Kit, Serum-Glutamat-Oxalacetat-Transaminase-Aktivitäts-Assay-Kit

Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise

Größe auswählen

1 KIT
€ 497,00

€ 497,00


Voraussichtliches Versanddatum07. April 2025


Bulk-Bestellung anfordern

Größe auswählen

Ansicht ändern
1 KIT
€ 497,00

About This Item

UNSPSC-Code:
12161503
NACRES:
NA.84

€ 497,00


Voraussichtliches Versanddatum07. April 2025


Bulk-Bestellung anfordern

Verwendung

sufficient for 100 colorimetric tests

Nachweisverfahren

colorimetric

Relevante Krankheit(en)

gastrointestinal diseases; cardiovascular diseases

Lagertemp.

−20°C

Angaben zum Gen

human ... GOT1(2805)
mouse ... GOT1(14718)
rat ... GOT1(24401)

Allgemeine Beschreibung

Das neue AST-Testkit, MAK467, ist jetzt erhältlich! Aspartat-Aminotransferase (AST), ehemals Serum-Glutamat-Oxalacetat-Transaminase (SGOT) genannt, ist ein Pyridoxalphosphat (PLP)-abhängiges Enzym, das die Umwandlung von Aspartat und α-Ketoglutarat in Oxalacetat und Glutamat katalysiert. Wie bei Alanin-Aminotransferase (ALT) werden AST-Werte im Blut gewöhnlich als Leberfunktionsmarker verwendet. AST hat jedoch eine breitere Gewebeverteilung als ALT und die AST-Werte können aufgrund von Erkrankungen oder Verletzungen unterschiedlicher Gewebe (einschließlich Skelett und Herz) schwanken.

Anwendung

Das AST-Aktivitäts-Assay-Kit wird für die Bestimmung der Aktivität von Aspartat-Aminotransferase in Proben verwendet.[1][2]

Leistungsmerkmale und Vorteile

Kompatibel mit Handhabungssystemen mit hohem Durchsatz.

Eignung

Geeignet für die Messung der Aspartat-Aminotransferase (AST)-Aktivität in biologischen Proben, wie Gewebe, Zellen und Serum.

Prinzip

Das AST-Aktivitäts-Assay-Kit ermöglicht ein einfaches, direktes Verfahren für die Messung der AST-Aktivität in verschiedenen Proben. In diesem Kit führt der Transfer einer Aminogruppe von Aspartat zu α-Ketoglutarat zu der Entstehung von Glutamat, was wiederum proportional zu der vorliegenden AST-enzymatischen Aktivität zur Entstehung eines kolorimetrischen Produkts führt (450 nm). Eine AST-Einheit ist definiert als die Menge an Enzym, die 1,0 μmol Glutamat pro Minute bei pH 8,0 und 37 °C generiert.

Ersetzt durch

Produkt-Nr.
Beschreibung
Preisangaben

Piktogramme

Health hazardCorrosion

Signalwort

Danger

H-Sätze

Gefahreneinstufungen

Eye Dam. 1 - Resp. Sens. 1 - Skin Corr. 1B

Lagerklassenschlüssel

8A - Combustible corrosive hazardous materials


Hier finden Sie alle aktuellen Versionen:

Analysenzertifikate (COA)

Lot/Batch Number

Die passende Version wird nicht angezeigt?

Wenn Sie eine bestimmte Version benötigen, können Sie anhand der Lot- oder Chargennummer nach einem spezifischen Zertifikat suchen.

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

Kunden haben sich ebenfalls angesehen

Slide 1 of 1

1 of 1

Zhiqiang Ye et al.
Journal of cellular biochemistry, 119(9), 7397-7405 (2018-05-19)
Liver ischemia/reperfusion (I/R) injury has high mortality due to the intense inflammatory process occurs in the liver. However, the pathological mechanism underlying I/R injury is still not clear. Recent works showed that circular RNAs play critical roles in many human
Resolvin D1 and E1 alleviate the progress of hepatitis toward liver cancer in long-term concanavalin A-induced mice through inhibition of NF-KB activity.
Kuang H, et al.
Oncology Reports, 35, 307-317 (2016)
Leola N Chow et al.
PloS one, 11(3), e0151765-e0151765 (2016-03-22)
Modulation of chemokine CXCL12 and its receptor CXCR4 has been implicated in attenuation of bleomycin (BLM)-induced pulmonary fibrosis and carbon tetrachloride (CCl4)-induced hepatic injury. In pulmonary fibrosis, published reports suggest that collagen production in the injured lung is derived from
Tiffany A Katz et al.
Environmental health perspectives, 128(1), 17010-17010 (2020-01-16)
Tributyltin (TBT) is a persistent and bioaccumulative environmental toxicant. Developmental exposure to TBT has been shown to cause fatty liver disease (steatosis), as well as increased adiposity in many species, leading to its characterization as an obesogen. We aimed to
Meli'sa S Crawford et al.
PloS one, 14(8), e0221392-e0221392 (2019-08-27)
The prevalence of metabolic syndrome (MetSyn) has risen 35% since 2012 and over two-thirds of Americans exhibit features characterizing this condition (obesity, dyslipidemia, hyperglycemia, insulin resistance and/or endothelial dysfunction). The aim of this study was to evaluate the effects of

Questions

1–5 of 5 Questions  
  1. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

  2. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf

      Helpful?

  3. Is it possible to use the MAK055 for an experiment that involves evaluating samples with and without B6 added? Additionally, will hemoglobin interfere if a blood hemolysate sample is used when assayed with this kit?

    1 answer
    1. The specific experiment in question has not been performed in the lab, and there are no references for the Aspartate Aminotransferase Activity Assay Kit where a similar experiment has been reported. Considering the nature of the assay and the fact that B6 is a co-enzyme of the ASP, necessary for its activity, in principle, the kit will be suitable to evaluate samples treated with B6. It will be necessary to evaluate any possible interferences and optimize user-specific conditions.
      It is possible that hemoglobin will interfere with the assay if hemolyzed blood is tested. Blood is generally not recommended as a sample, unless specifically mentioned in the assay, due to the possible interference as mentioned. Furthermore, the kit has not been tested with blood samples.

      Helpful?

  4. Does the AST Activity Assay Kit (MAK055), which includes a positive control (MAK055F), have a specific species origin? For instance, is it Human AST?

    1 answer
    1. The positive control in MAK055 is derived from porcine heart.

      Helpful?

  5. Do you anticipate phenol red in culture medium having an impact on the colorimetric read out at 450 nm? (I'm thinking there may be some spectral overlap)

    1 answer
    1. Ideally, culture media should be phenol red-free.

      Helpful?

Reviews

No rating value

Active Filters

Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..

Setzen Sie sich mit dem technischen Dienst in Verbindung.