跳轉至內容
Merck

Investigation of dendriplexes by ion mobility-mass spectrometry.

Molecules (Basel, Switzerland) (2014-12-17)
Emma-Dune Leriche, Marie Hubert-Roux, Carlos Afonso, Catherine M Lange, Martin C Grossel, Florian Maire, Corinne Loutelier-Bourhis
摘要

Highly branched polyamidoamine (PAMAM) dendrimers presenting biological activities have been envisaged as non-viral gene delivery vectors. They are known to associate with nucleic acid (DNA) in non-covalent complexes via electrostatic interactions. Although their transfection efficiency has been proved, PAMAMs present a significant cytotoxicity due to their cationic surface. To overcome such a drawback, different chemical modifications of the PAMAM surface have been reported such as the attachment of hydrophobic residues. In the present work, we studied the complexation of DNA duplexes with different low-generation PAMAM; ammonia-cored G0(N) and G1(N) PAMAM, native or chemically modified with aromatic residues, i.e., phenyl-modified-PAMAM G0(N) and phenylalanine-modified-PAMAM G1(N). To investigate the interactions involved in the PAMAM/DNA complexes, also called dendriplexes, we used electrospray ionization (ESI) coupled to ion mobility spectrometry-mass-spectrometry (IM-MS). ESI is known to allow the study of non-covalent complexes in native conditions while IM-MS is a bidimensional separation technique particularly useful for the characterization of complex mixtures. IM-MS allows the separation of the expected complexes, possible additional non-specific complexes and the free ligands. Tandem mass spectrometry (MS/MS) was also used for the structural characterization. This work highlights the contribution of IM-MS and MS/MS for the study of small dendriplexes. The stoichiometries of the complexes and the equilibrium dissociation constants were determined. The [DNA/native PAMAM] and [DNA/modified-PAMAM] dendriplexes were compared.

材料
產品編號
品牌
產品描述

Sigma-Aldrich
乙腈, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
甲醇, suitable for HPLC, ≥99.9%
Sigma-Aldrich
二氯甲烷, suitable for HPLC, ≥99.8%, contains amylene as stabilizer
Sigma-Aldrich
甲醇, ACS reagent, ≥99.8%
Sigma-Aldrich
乙腈, HPLC Plus, ≥99.9%
Sigma-Aldrich
N,N-二甲基甲酰胺, ACS reagent, ≥99.8%
Sigma-Aldrich
二氯甲烷, contains 40-150 ppm amylene as stabilizer, ACS reagent, ≥99.5%
Sigma-Aldrich
甲醇, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
N,N-二甲基甲酰胺, suitable for HPLC, ≥99.9%
Sigma-Aldrich
磷酸, ACS reagent, ≥85 wt. % in H2O
Sigma-Aldrich
甲醇, HPLC Plus, ≥99.9%
Sigma-Aldrich
二氯甲烷, HPLC Plus, for HPLC, GC, and residue analysis, ≥99.9%, contains 50-150 ppm amylene as stabilizer
Sigma-Aldrich
乙酸铵, ACS reagent, ≥97%
Sigma-Aldrich
乙腈, ACS reagent, ≥99.5%
Sigma-Aldrich
磷酸, 85 wt. % in H2O, 99.99% trace metals basis
Sigma-Aldrich
磷酸, ACS reagent, ≥85 wt. % in H2O
Sigma-Aldrich
乙腈, ≥99.9% (GC)
Sigma-Aldrich
乙酸铵, ≥99.99% trace metals basis
Sigma-Aldrich
乙腈, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
2,2,2-三氟乙醇, ReagentPlus®, ≥99%
Sigma-Aldrich
N,N-二异丙基乙胺, 99.5%, biotech. grade
Sigma-Aldrich
磷酸, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥85%
Sigma-Aldrich
N,N-二甲基甲酰胺, puriss. p.a., ACS reagent, reag. Ph. Eur., ≥99.8% (GC)
Sigma-Aldrich
甲醇, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.8% (GC)
Sigma-Aldrich
二氯甲烷, puriss. p.a., ACS reagent, reag. ISO, ≥99.9% (GC)
Sigma-Aldrich
二氯甲烷, ACS reagent, ≥99.5%, contains 40-150 ppm amylene as stabilizer
Sigma-Aldrich
磷酸, crystalline, ≥99.999% trace metals basis
Sigma-Aldrich
甲醇, Laboratory Reagent, ≥99.6%
Sigma-Aldrich
磷酸, puriss. p.a., crystallized, ≥99.0% (T)
Sigma-Aldrich
N,N-二甲基甲酰胺, ReagentPlus®, ≥99%