跳轉至內容
Merck
全部照片(1)

重要文件

1193265

USP

二乙二醇

United States Pharmacopeia (USP) Reference Standard

同義詞:

2,2′-氧代二乙醇, 2-羟基乙基醚, 二(羟乙基)醚, 二甘醇

登入查看組織和合約定價


About This Item

線性公式:
(HOCH2CH2)2O
CAS號碼:
分子量::
106.12
Beilstein:
969209
MDL號碼:
分類程式碼代碼:
41116107
PubChem物質ID:
NACRES:
NA.24
暫時無法取得訂價和供貨情況

蒸汽密度

2.14 (vs air)

蒸汽壓力

0.01 mmHg ( 20 °C)

API 家族

diethylene glycol

自燃溫度

442 °F

expl. lim.

2-12.3 %

製造商/商標名

USP

折射率

n20/D 1.447 (lit.)

bp

245 °C (lit.)

mp

−10 °C (lit.)

密度

1.118 g/mL at 25 °C (lit.)

應用

pharmaceutical (small molecule)

形式

neat

SMILES 字串

OCCOCCO

InChI

1S/C4H10O3/c5-1-3-7-4-2-6/h5-6H,1-4H2

InChI 密鑰

MTHSVFCYNBDYFN-UHFFFAOYSA-N

尋找類似的產品? 前往 產品比較指南

一般說明

本品按现行药典规定交付。所有为支持本产品而提供的信息,包括SDS和任何产品信息单均由药典颁发机构制定并发布。如需进一步信息和支持,请访问现行药典网站。

應用

Diethylene glycol USP reference standard, intended for use in specified quality tests and assays as specified in the USP compendia. Also, for use with USP monographs such as:
  • Propylene Glycol
  • Glycerin
  • Polyoxyl 40 Hydrogenated Castor Oil
  • Sorbitol Solution
  • Polyethylene Glycol 3350
  • Maltitol Solution
  • Noncrystallizing Sorbitol Solution

分析報告

这些产品仅供测试和分析使用。它们不适用于人类或动物的给药,不可用于诊断、治疗或治愈任何疾病。  ​

其他說明

可能适用相应的销售限制。

相關產品

象形圖

Exclamation mark

訊號詞

Warning

危險聲明

危險分類

Acute Tox. 4 Oral

儲存類別代碼

10 - Combustible liquids

水污染物質分類(WGK)

WGK 1

閃點(°F)

280.4 °F - closed cup

閃點(°C)

138 °C - closed cup


從最近期的版本中選擇一個:

分析證明 (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our 文件 section.

如果您需要協助,請聯絡 客戶支援

已經擁有該產品?

您可以在文件庫中找到最近購買的產品相關文件。

存取文件庫

Glycerin
United States Pharmacopeia and National Formulary
United States Pharmacopeia, 28(4), 2123-2123 (2020)
Propylene Glycol
United States Pharmacopeia and National Formulary
United States Pharmacopeia, 33(2), 3753-3753 (2020)
Polyethylene Glycol 3350
United States Pharmacopeia and National Formulary
United States Pharmacopeia, 41(4), 3584-3584 (2020)
J L Hébert et al.
La semaine des hopitaux : organe fonde par l'Association d'enseignement medical des hopitaux de Paris, 59(5), 344-349 (1983-02-03)
Although acute poisoning with ethylene glycol (EG) used in antifreeze mixtures is well known in man, only a few reports have described acute intoxication with diethylene glycol (DEG) and only one has mentioned oxaluria. Furthermore, there is no experimental evidence
Nestor R Sosa et al.
Annals of emergency medicine, 64(1), 38-47 (2014-01-21)
Diethylene glycol is a toxic industrial solvent responsible for more than 13 mass poisonings since 1937. Little is known about the clinical spectrum, progression, and neurotoxic potential of diethylene glycol-associated disease because of its high mortality and the absence of

條款

99%;甘油,≥99.5%;四甘醇,99%

Questions

1–4 of 4 Questions  
  1. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

  2. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf

      Helpful?

  3. What is the electrical conductivity of this product?

    1 answer
    1. The electrical conductivity for this material is not determined.

      Helpful?

  4. What is the electrical conductivity of this product?

    1 answer
    1. This is a product of the USP (United States Pharmacopeia). The electrical conductivity is not determined by USP for this material. For more information regarding this item, please view the link below: https://store.usp.org/product/1193265

      Helpful?

Reviews

No rating value

Active Filters

我們的科學家團隊在所有研究領域都有豐富的經驗,包括生命科學、材料科學、化學合成、色譜、分析等.

聯絡技術服務