Unfortunately, the solution stability of this product is not determined. It is recommended to use freshly prepared solutions.
推薦產品
描述
non-ionic
形狀
paste
成份
free macrogoly% (27.0 - 39.0 g/100g (%))
雜質
acetic acid (≤ 0.5 g/100g (%))
water (≤ 0.5 g/100g (%))
≤0.05% acetic acid
≤0.05% water
≤1 mg/kg ethylene oxide ((ppm))
≤1 mg/kg ethylene oxide
≤1 mg/kg nickel ((ppm))
≤1 mg/kg nickle
≤10 mg/kg dioxane ((ppm))
≤10 mg/kg dioxane
≤10 mg/kg heavy metals
≤620 mg/kg Diethylene glycol
≤620 mg/kg diethylene glycol ((ppm))
≤620 mg/kg ethylene glycol ((ppm))
≤620 mg/kg ethylene glycol
<10 mg/kg heavy metals ((ppm))
燃燒殘留物
(≤ 0.3 g/100g (%))
pH值
5.0-7.0 (1 g/10 mL in H2O)
mp
25 - 30 °C (77 - 86 °F)
酸價
≤1.0 mg KOH/g
羥值
90‑110 mg KOH/g
碘值
≤2.0 g I2/100 g
過氧化值
≤3.0 meq/kg
皂化值
53‑63 mg KOH/g
溶解度
water: 200 g/L at 30 °C (86 °F)
密度
1.048 g/cm3 at 20 °C (68 °F)
1.03 g/cm3 at 60 °C (140 °F)
負離子痕跡
<1 ppm (Ethylene Oxide)
<10 ppm (Dioxane)
正離子痕跡
Ni: <1 ppm
heavy metals: <10 ppm
應用
sample preservation
SMILES 字串
C(CCCCC(CCCCCCOCCOCCOCCOCCOCCOCCOCCOCCOCCOCCOCCOCCOCCOCCOCCO)O)CCCCC(=O)O
InChI
1S/C47H94O19/c48-15-17-53-19-21-55-23-25-57-27-29-59-31-33-61-35-37-63-39-41-65-43-45-66-44-42-64-40-38-62-36-34-60-32-30-58-28-26-56-24-22-54-20-18-52-16-11-7-6-9-13-46(49)12-8-4-2-1-3-5-10-14-47(50)51/h46,48-49H,1-45H2,(H,50,51)
InChI 密鑰
CYAMZYIUAHNTBO-UHFFFAOYSA-N
一般說明
應用
- 聚乙二醇12羟基硬脂酸酯已用于:
- 溶解于地塞米松(DEX),以将其腹腔注射到小鼠体内,测试其握力,进而测量肌肉力量
- 以罗氟司特制剂治疗家兔和豚鼠,以研究臭氧诱导的剧烈咳嗽(hypertussive)反应的机制和药理敏感性
- 溶解非奈利酮,以进行口服应用的体内研究
生化/生理作用
法律資訊
客戶也查看了
-
Hi how do you store solutol ? at RT, it solidifies
1 answer-
Helpful?
-
-
How can I determine the shelf life / expiration / retest date of this product?
1 answer-
If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdfHelpful?
-
-
How is shipping temperature determined? And how is it related to the product storage temperature?
1 answer-
Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf
Helpful?
-
-
Hi, What is the recommended storage condition for Kolliphor HS 15 and what is the expected shelf life corresponding the storage condition? Thank you!
1 answer-
This product can be stored at room temperature. Products that are robust in nature and extremely stable, in the original unopened container, are not assigned an expiration date or retest schedule. These products will have no dating reported on either the label or the Certificate of Analysis.
Products that are not assigned an expiration or retest date are covered by a warranty period of 1 year from the date of product shipment.
Full Product Dating Information may be reviewed at the link below: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/190/408/product-dating-information-ms.pdf
Helpful?
-
-
Hi; please, can i have the spectrum IR of macrogol-15-hydroxystearate (lot BBCH6204); best regard.
1 answer-
The attached brochure and attributes table details the M-Clarity™ Program, and the discriminating quality elements for each product level: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/400/043/clarity-program-brochure-br3925en-mk.pdf
https://www.sigmaaldrich.com/content/dam/sigma-aldrich/docs/Sigma-Aldrich/General_Information/2/M-Clarity_attributes_table_mk.pdfThe product is marketed as level M-Clarity™ MQ100, MQ200, or MQ300, and as such, does not offer analytical method information (batch testing information / “for-cost” testing). Such a service is offered on products marketed as M-Clarity™ MQ400, and above. For questions regarding M-Clarity™ Program or other product detail, please navigate to the link https://www.sigmaaldrich.com/techservice, click on "Product Technical Inquiries" under the Products Section with all the required information so that a member of the Technical Service team can reach out to assist further. Thank you.
Helpful?
-
Active Filters
我們的科學家團隊在所有研究領域都有豐富的經驗,包括生命科學、材料科學、化學合成、色譜、分析等.
聯絡技術服務