跳轉至內容
Merck
全部照片(2)

重要文件

N21588

Sigma-Aldrich

2-硝基苯肼

97%

同義詞:

1-肼-2-硝基苯, 1-(2-硝基苯基)肼, 2-硝基苯肼, 2-肼-1-硝基苯, 邻硝基苯肼, 邻肼硝基苯

登入查看組織和合約定價


About This Item

線性公式:
O2NC6H4NHNH2
CAS號碼:
分子量::
153.14
Beilstein:
512797
EC號碼:
MDL號碼:
分類程式碼代碼:
12352100
PubChem物質ID:
NACRES:
NA.22
暫時無法取得訂價和供貨情況

品質等級

化驗

97%

形狀

powder

包含

30% water as stabilizer (minimum)

mp

91-93 °C (lit.)

儲存溫度

2-8°C

SMILES 字串

NNc1ccccc1[N+]([O-])=O

InChI

1S/C6H7N3O2/c7-8-5-3-1-2-4-6(5)9(10)11/h1-4,8H,7H2

InChI 密鑰

FRBUNLLUASHNDJ-UHFFFAOYSA-N

尋找類似的產品? 前往 產品比較指南

象形圖

FlameExclamation mark

訊號詞

Danger

危險分類

Acute Tox. 4 Oral - Eye Irrit. 2 - Flam. Sol. 1 - Skin Irrit. 2 - STOT SE 3

標靶器官

Respiratory system

儲存類別代碼

4.1B - Flammable solid hazardous materials

水污染物質分類(WGK)

WGK 3

閃點(°F)

Not applicable

閃點(°C)

Not applicable


從最近期的版本中選擇一個:

分析證明 (COA)

Lot/Batch Number

未看到正確版本?

如果您需要一個特定的版本,您可以透過批號來尋找特定憑證。

已經擁有該產品?

您可以在文件庫中找到最近購買的產品相關文件。

存取文件庫

客戶也查看了

Vida Časaitė et al.
Applied and environmental microbiology, 86(15) (2020-05-31)
Pyridine and its derivatives constitute the majority of heterocyclic aromatic compounds that occur largely as a result of human activities and contribute to environmental pollution. It is known that they can be degraded by various bacteria in the environment; however
A I Fattom et al.
Infection and immunity, 66(10), 4588-4592 (1998-09-24)
Bacterial capsular polysaccharides (CP) are carbohydrate polymers comprised of repeating saccharide units. Several of these CP have side chains attached to their backbone structures. The side chains may include O-acetyl, phosphate, sialic acid, and other moieties. Those moieties represent the
Gregory C Henderson et al.
Analytical biochemistry, 413(1), 66-68 (2011-02-18)
Previously, following derivatization to their 2-nitrophenylhydrazide (2-NPH) derivatives, fatty acid (FA) abundances have been evaluated using high-performance liquid chromatography (HPLC). Although the method was sensitive, resolution was insufficient for many of the biologically important FAs. We have developed an enhanced
T Takeuchi et al.
Clinica chimica acta; international journal of clinical chemistry, 205(1-2), 117-126 (1992-01-31)
An automated assay method has been developed for the measurement of serum cholinesterase activity. The samples were prepared by an automated liquid handling unit and incubated for 9.7 min at 30 degrees C, followed by automatic injection into a colorimetric
Junmei Zhang et al.
Journal of the American Society for Mass Spectrometry, 22(11), 1958-1967 (2011-09-29)
Peptides with two or more basic residues, including those with post-translational modifications (PTMs), such as methylation and phosphorylation, can be highly hydrophilic and, therefore, are often difficult to be retained on a reversed-phase (RP) column. In addition, these highly hydrophilic

Questions

Reviews

No rating value

Active Filters

我們的科學家團隊在所有研究領域都有豐富的經驗,包括生命科學、材料科學、化學合成、色譜、分析等.

聯絡技術服務