跳转至内容
Merck
所有图片(1)

主要文件

F6182

Sigma-Aldrich

Fluoroshield

liquid

登录查看公司和协议定价

选择尺寸

20 ML
$212.00

$212.00


有货详情


获取大包装报价

选择尺寸

变更视图
20 ML
$212.00

About This Item

分類程式碼代碼:
12171500
NACRES:
NA.47

$212.00


有货详情


获取大包装报价

产品名称

Fluoroshield, histology mounting medium

品質等級

形狀

liquid

技術

immunofluorescence: suitable

pH值範圍

7.8-8.2

溶解度

water: soluble

應用

diagnostic assay manufacturing
hematology
histology

儲存溫度

2-8°C

一般說明

Fluoroshield封固剂是一种水性封固剂,用于保持组织和细胞涂片的荧光。这种独特的配方不仅可以延长荧光时间,还可防止FITC、Texas Red®、AMCA、 Cy®、Cy3、Cy5、Alexa Fluor 488、Alexa Fluor 594、绿色荧光蛋白(GFP)、四甲基罗丹明、R-藻红蛋白(R-PE)、藻蓝蛋白(PC)和别藻蓝蛋白(APC)等荧光染料的快速光漂白效应(褪色)。

應用

Fluoroshield 用于:
  • 作为经培养的巨核细胞和免疫染色的血小板的固封剂,用于共聚焦显微镜研究[1]
  • 作为4′,6-二氨基-2-苯基吲哚(DAPI)染色的心脏切片的固封剂,用于免疫荧光研究[2]
  • 保持C6细胞涂片的荧光[3]

聯結

Fluoroshield 是一种与凝胶支架相当的水性封片剂

法律資訊

ALEXA FLUOR is a trademark of Life Technologies
Cy is a registered trademark of Cytiva
Cy3 is a trademark of Cytiva
FluoroShield is a trademark of ImmunoBioScience Corp.
Gel Mount is a trademark of Biomeda Corp.
Texas Red is a registered trademark of Life Technologies

相關產品

儲存類別代碼

10 - Combustible liquids

水污染物質分類(WGK)

WGK 1

閃點(°F)

Not applicable

閃點(°C)

Not applicable


历史批次信息供参考:

分析证书(COA)

Lot/Batch Number

没有发现合适的版本?

如果您需要特殊版本,可通过批号或批次号查找具体证书。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

Effects of dexamethasone on C6 cell proliferation, migration and invasion through the upregulation of AQP1
Guan Y, et al.
Oncology Letters, 15(5), 7595-7602 (2018)
Ahmed Baker Alshaikh et al.
Reproductive biology and endocrinology : RB&E, 18(1), 75-75 (2020-07-25)
Fertility preservation is particularly challenging in young women diagnosed with hematopoietic cancers, as transplantation of cryopreserved ovarian cortex in these women carries the risk for re-introducing cancer cells. Therefore, the construction of a bioengineered ovary that can accommodate isolated small
Chenchen Yang et al.
Scientific reports, 8(1), 16359-16359 (2018-11-07)
Visibly transparent luminescent solar concentrators (TLSC) have the potential to turn existing infrastructures into net-zero-energy buildings. However, the reabsorption loss currently limits the device performance and scalability. This loss is typically defined by the Stokes shift between the absorption and
Jackson J Fyfe et al.
Scientific reports, 8(1), 560-560 (2018-01-14)
Combining endurance training with resistance training (RT) may attenuate skeletal muscle hypertrophic adaptation versus RT alone; however, the underlying mechanisms are unclear. We investigated changes in markers of ribosome biogenesis, a process linked with skeletal muscle hypertrophy, following concurrent training
Britta Püttmann et al.
Neuro-Signals, 14(3), 85-95 (2005-08-10)
It has previously been shown that skeletal myotubes express nitric oxide synthase (NOS) and produce and release NO signals. NOS is also part of agrin-induced acetylcholine receptor aggregations on myotubes. As nerve-muscle interactions underlie reciprocal signaling mechanisms, we hypothesized that

商品

Human Protein Atlas uses A-431, U-251 MG, and U-205 cell lines with Prestige Antibodies for organelle mapping.

Questions

1–9 of 9 Questions  
  1. What is the refractive index of this product (Fluoroshield Histology Mounting Medium, F6182)?

    1 answer
    1. The refractive index is 1.364 ± 0.002. This number applies to this mounting medium in solution. Refractive indexes change when the mounting media dries on the slide.

      Helpful?

  2. Does this product harden as it dries? Also, what is it's shelf life?

    1 answer
    1. This is an aqueous mounting medium and will dry over time if exposed to air, however this is unrelated to the intended use of the product. The mounting medium is applied over the sample prior to the addition of the coverslip. See the brief protocol below:

      1. Bring the vial to room temperature.
      2. Rinse slide to be mounted with DISTILLED OR DEIONIZED WATER, then touch the edges of slide on a paper towel to remove excess water. Place slides on a flat surface away from light.
      3. Turn the vial upside down and remove any air bubbles.
      4. Apply 3-4 drops directly of mounting medium on top of the specimen and spread out evenly by tilting the slide back and forth or spread evenly with a 0.2 ml plastic pipette tip, making sure the tissue is not touched. Excess medium can be removed by touching the edges of slide on paper towel.
      5. Let stand at room temperature for about 5 minutes.
      6. Apply cover slip, carefully avoiding air bubbles.
      7. The specimen is ready for visualization under microscope.
      8. One can seal the edges of cover slip with nail polish or any organic medium. If coverslip is not used air bubbles will appear in few days.
      9. For long term storage it is recommended that the slide be stored in the dark at 2-8°C.

      This product is assigned an expiration date of approximately one year. Please view the sample Certificate of Analysis: https://www.sigmaaldrich.com/certificates/sapfs/PROD/sap/certificate_pdfs/COFA/Q14/F6182-20ML-PWMKCT0475.pdf.

      Helpful?

  3. How do I store Fluoroshield (Product Nos. F6182, F5932, F6057) ?

    1 answer
    1. This product is stored at 2-8°C.  Protect from light, and do not freeze.

      Helpful?

  4. How do you remove the coverslip when using Fluoroshield (Product Nos. F6182, F5932, F6057)?

    1 answer
    1. The coverslip can be removed before sealing the edges. Soak slide in warm (37  °C) water for a few minutes. Carefully and slowly move the coverslip. Soak in water for an additional few minutes to remove coverslip. Rinse slide several times with warm water to remove all mounting medium. The slide can be remounted again.

      Helpful?

  5. How does the storage temperature relate to shipping conditions?

    1 answer
    1. The storage conditions that a Sigma-Aldrich catalog and label recommend for products are deliberately conservative. For many products, long-term storage at low temperatures will increase the time during which they are expected to remain in specification and therefore are labeled accordingly. Where short-term storage, shipping time frame, or exposure to conditions other than those recommended for long-term storage will not affect product quality, Sigma-Aldrich will ship at ambient temperature. The products sensitive to short-term exposure to conditions other than their recommended long-term storage are shipped on wet or dry ice. Ambient temperature shipping helps to control shipping costs for our customers. At any time, our customers can request wet- or dry-ice shipment, but the special handling is at customer expense if our product history indicates that the product is stable for regular shipment.

      Helpful?

  6. What is the Department of Transportation shipping information for this product?

    1 answer
    1. Transportation information can be found in Section 14 of the product's (M)SDS.To access the shipping information for this material, use the link on the product detail page for the product.

      Helpful?

  7. What fluorochromes can be used with Fluoroshield (Product Nos. F6182, F5932, F6057)?

    1 answer
    1. This unique formula prevents rapid photobleaching of FITC, Texas Red®, AMCA, Cy®2, Cy®3, Cy®5, Alexa Fluor® 488, Alexa Fluor® 594, green fluorescent protein (GFP), tetramethylrhodamine, R-phycoerythrin (R-PE), phycocyanin (PC), and allophycocyanin (APC).  Fluorescence is retained during prolonged storage at 4°C in the dark. This medium does not contain phenylenediamine, which destroys immunofluorescence of the Cy dyes, RP-E, PC and APC.

      Helpful?

  8. Does Fluoroshield (Product Nos. F6182, F5932, F6057) contain an antifade reagent?

    1 answer
    1. This unique formula prevents rapid photobleaching.  The exact nature of the antifade is considered proprietary.

      Helpful?

  9. How do I use Fluoroshield (Product Nos. F6182, F5932, F6057)?

    1 answer
    1. 1. Bring the vial to room temperature. 2. Rinse slide to be mounted with DISTILLED OR DEIONIZED WATER, then touch the edges of slide on a paper towel to remove excess water. Place slides on a flat surface away from light. 3. Turn the vial upside down and remove any air bubbles. 4. Apply 3-4 drops directly of mounting medium on top of the specimen and spread out evenly by tilting the slide back and forth or spread evenly with a 0.2 ml plastic pipette tip, making sure the tissue is not touched. Excess medium can be removed by touching the edges of slide on paper towel. 5. Let stand at room temperature for about 5 minutes. 6. Apply cover slip, carefully avoiding air bubbles. 7. The specimen is ready for visualization under microscope. 8. One can seal the edges of cover slip with nail polish or any organic medium. If coverslip is not used air bubbles will appear in few days. 9. For long term storage it is recommended that the slide be stored in the dark at 2-8°C.

      Helpful?

Reviews

No rating value

Active Filters

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系技术服务部门