The product MAK106 uses linear regression fitting. The standard curve is prepared based on the donor particle concentration indicated on the label, which is batch-specific. The standard curve in table 2 is representative and for example purposes only. It's important to note that the concentrations may vary. The pmole values are calculated through dimension analysis using the amount of donor particle solution used and any subsequent dilution. For example, the most concentrated standard can be calculated by considering the volume of the donor particle. In this case, the most concentrated standard has 130 pmoles. Each subsequent dilution is two times less concentrated, resulting in concentrations of 65, 32.5, 16.25, and 8.1 pmoles.
Przejdź do
Wybierz wielkość
| Rozmiar/SKU | Dostępność | Cena netto |
|---|---|---|
1 kit | Skontaktuj się z Obsługą Klienta, aby uzyskać informacje na temat dostępności | 3400,00 zł |
Informacje o tej pozycji
3400,00 zł
usage
sufficient for 100 fluorometric tests
application(s)
pharmaceutical
detection method
fluorometric
relevant disease(s)
cardiovascular diseases
storage temp.
2-8°C
Gene Information
human ... CETP(1071)
General description
Application
Biochem/physiol Actions
Features and Benefits
1 of 1
Ta pozycja | |||
|---|---|---|---|
| description Supplied by Roar Biomedical, Inc. | description (Supplied by Roar Biomedical, Inc.) | description Supplied by Roar Biomedical, Inc. | description Supplied by Roar Biomedical, Inc. |
| Gene Information human ... CETP(1071) | Gene Information - | Gene Information human ... PLTP(5360) | Gene Information human ... MTTP(4547) |
| usage sufficient for 100 fluorometric tests | usage sufficient for 100 fluorometric tests | usage sufficient for 100 fluorometric tests | usage sufficient for 100 fluorometric tests |
| detection method fluorometric | detection method fluorometric | detection method fluorometric | detection method fluorometric |
| storage temp. 2-8°C | storage temp. 2-8°C | storage temp. 2-8°C | storage temp. 2-8°C |
| application(s) pharmaceutical | application(s) pharmaceutical | application(s) pharmaceutical | application(s) pharmaceutical |
| relevant disease(s) cardiovascular diseases | relevant disease(s) cardiovascular diseases | relevant disease(s) cardiovascular diseases | relevant disease(s) cardiovascular diseases |
Klasa składowania
10 - Combustible liquids
Wybierz jedną z najnowszych wersji:
Masz już ten produkt?
Dokumenty związane z niedawno zakupionymi produktami zostały zamieszczone w Bibliotece dokumentów.
-
What type of regression fitting is used for the product MAK106, and what is the method for calculating the pmoles shown in the typical standard curve in table 2?
1 answer-
Helpful?
-
