Przejdź do zawartości
Merck

09735

Ammonium formate

BioUltra, ≥99.0% (calc. based on dry substance, NT)

Synonim(y):

Formic acid ammonium salt

Zaloguj się, aby wyświetlić ceny organizacyjne i kontraktowe.

Wybierz wielkość

50 G

536,00 zł

250 G

1780,00 zł

536,00 zł


Skontaktuj się z Obsługą Klienta, aby uzyskać informacje na temat dostępności

Zamów zamówienie zbiorcze

Informacje o tej pozycji

Wzór liniowy:
HCO2NH4
Numer CAS:
Masa cząsteczkowa:
63.06
NACRES:
NA.25
PubChem Substance ID:
eCl@ss:
39021903
UNSPSC Code:
12352107
EC Number:
208-753-9
MDL number:
Beilstein/REAXYS Number:
3625095

Przejdź do

Pomoc techniczna
Potrzebujesz pomocy? Nasz zespół doświadczonych naukowców chętnie Ci pomoże.
Pozwól nam pomóc

product line

BioUltra

Quality Level

assay

≥99.0% (calc. based on dry substance, NT)

form

crystals

impurities

insoluble matter, passes filter test, ≤2% water

ign. residue (900 °C)

≤0.1% (as SO4)

pH

5.5-7.5 (25 °C, 1 M in H2O)

mp

119-121 °C (lit.)

solubility

H2O: 1 M at 20 °C, clear, colorless

density

1.26 g/mL at 25 °C (lit.)

anion traces

chloride (Cl-): ≤50 mg/kg, sulfate (SO42-): ≤50 mg/kg

cation traces

Al: ≤5 mg/kg, As: ≤0.1 mg/kg, Ba: ≤5 mg/kg, Bi: ≤5 mg/kg, Ca: ≤10 mg/kg, Cd: ≤5 mg/kg, Co: ≤5 mg/kg, Cr: ≤5 mg/kg, Cu: ≤5 mg/kg, Fe: ≤5 mg/kg, K: ≤50 mg/kg, Li: ≤5 mg/kg, Mg: ≤5 mg/kg, Mn: ≤5 mg/kg, Mo: ≤5 mg/kg, Na: ≤50 mg/kg, Ni: ≤5 mg/kg, Pb: ≤5 mg/kg, Sr: ≤5 mg/kg, Zn: ≤5 mg/kg

λ

1 M in H2O

UV absorption

λ: 260 nm Amax: ≤0.01, λ: 280 nm Amax: ≤0.01

SMILES string

N.OC=O

InChI

1S/CH2O2.H3N/c2-1-3;/h1H,(H,2,3);1H3

InChI key

VZTDIZULWFCMLS-UHFFFAOYSA-N

Szukasz podobnych produktów? Odwiedź Przewodnik dotyczący porównywania produktów

Porównaj podobne pozycje

Wyświetl pełne porównanie

Pokaż różnice

1 of 4

Ta pozycja
7985687022178314
product line

BioUltra

product line

Redi-Dri

product line

-

product line

BioUltra

assay

≥99.0% (calc. based on dry substance, NT)

assay

97%

assay

≥99.0% (calc. on dry substance, NT)

assay

-

form

crystals

form

crystals

form

crystals

form

liquid

impurities

insoluble matter, passes filter test

impurities

-

impurities

insoluble matter, passes filter test, <2% water

impurities

insoluble matter, passes filter test

ign. residue (900 °C)

≤0.1% (as SO4)

ign. residue (900 °C)

-

ign. residue (900 °C)

-

ign. residue (900 °C)

-

pH

5.5-7.5 (25 °C, 1 M in H2O)

pH

-

pH

5.5-7.5 (25 °C, 1 M in H2O)

pH

6.0-8.0 (25 °C, 10 M in H2O)

Application

Ammonium formate can be used to study biological buffers. Ammonium formate has been used in a study to develop an ultrasensitive and selective high performance liquid chromatographic method for one of volatile signaling phytohormones, jasmonic acid (JA). Ammonium formate has also been used in a study to develop and validate a direct injection liquid chromatography-electrospray ionization-tandem mass spectrometric method (LC-ESI-MS/MS) for the rapid and simple determination of 13 phenylalkylamine derivatives.

Other Notes

Buffer component in the separation and purification of glycosaminoglycans from complex systems by affinity chromatography with Polybrene[1].
Ta strona może zawierać tekst przetłumaczony maszynowo.

pictograms

Exclamation mark

signalword

Warning

hcodes

Hazard Classifications

Eye Irrit. 2

Klasa składowania

11 - Combustible Solids

flash_point_f

Not applicable

flash_point_c

Not applicable

ppe

dust mask type N95 (US), Eyeshields, Gloves


Wybierz jedną z najnowszych wersji:

Certyfikaty analizy (CoA)

Lot/Batch Number

Nie widzisz odpowiedniej wersji?

Jeśli potrzebujesz konkretnej wersji, możesz wyszukać konkretny certyfikat według numeru partii lub serii.

Masz już ten produkt?

Dokumenty związane z niedawno zakupionymi produktami zostały zamieszczone w Bibliotece dokumentów.

Odwiedź Bibliotekę dokumentów

B A Hodson et al.
Journal of chromatography, 565(1-2), 416-423 (1991-04-19)
A new system for the isolation and purification of glycosaminoglycans (GAGs) and related molecules from complex systems such as plasma is described. Affinity chromatography which exploits the very high affinity between the polymeric base Polybrene and sulphated polysaccharides was used.
Anne M Filppula et al.
Drug metabolism and disposition: the biological fate of chemicals, 42(7), 1202-1209 (2014-04-10)
Previous studies have shown that several protein kinase inhibitors are time-dependent inhibitors of cytochrome P450 (CYP) 3A. We screened 14 kinase inhibitors for time-dependent inhibition of CYP2C8 and CYP3A. Amodiaquine N-deethylation and midazolam 1'-hydroxylation were used as marker reactions for
Therese Fagerqvist et al.
Journal of neurochemistry, 126(1), 131-144 (2013-02-01)
Inclusions of intraneuronal alpha-synuclein (α-synuclein) can be detected in brains of patients with Parkinson's disease and dementia with Lewy bodies. The aggregation of α-synuclein is a central feature of the disease pathogenesis. Among the different α-synuclein species, large oligomers/protofibrils have
Sai Duan et al.
Physical chemistry chemical physics : PCCP, 15(13), 4625-4633 (2013-02-21)
Local structures and adsorption energies of a formic acid molecule and its decomposed intermediates (H, O, OH, CO, HCOO, and COOH) on highly electrocatalytically active mushroom-like Au-core@Pd-shell@Pt-cluster nanoparticles with two atomic layers of the Pd shell and stoichiometric Pt coverage
Jo Philips et al.
Journal of contaminant hydrology, 147, 25-33 (2013-03-19)
Acidification due to microbial dechlorination of trichloroethene (TCE) can limit the bio-enhanced dissolution of TCE dense non-aqueous phase liquid (DNAPL). This study related the dissolution enhancement of a TCE DNAPL to the pH buffer capacity of the medium and the

Powiązane treści

Numer pozycji handlu globalnego

SKUNUMER GTIN
09735-250G04061838657664
09735-50G04061838657671

Questions

1–3 of 3 Questions  
  1. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/418/501/product-dating-information-06-25-mk.pdf

      Helpful?

  2. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

  3. Why the COA doesn't contain expiry date? How to determine the expiry date of the chemicals

    1 answer
    1. This product is not assigned an expiration date. It is assigned a recommended retest date of approximately 3.5 years after the quality release date. A recommended retest date is the time during which the product is expected to remain within established stability specifications, provided that it has been stored under defined conditions. After the Retest Date, product samples should be examined to ensure that the product is still in compliance with the established specifications.

      For more information, you may access the "Product Dating Information" document under "ADDITIONAL USEFUL DOCUMENTS ABOUT OUR PRODUCTS" at the bottom of the Quality Services page with this link: https://www.sigmaaldrich.com/US/en/life-science/quality-and-regulatory-management/quality-services.

      Helpful?

Reviews

No rating value

Active Filters

Nasz zespół naukowców ma doświadczenie we wszystkich obszarach badań, w tym w naukach przyrodniczych, materiałoznawstwie, syntezie chemicznej, chromatografii, analityce i wielu innych dziedzinach.

Skontaktuj się z zespołem ds. pomocy technicznej