EQCYTMAG-93K
MILLIPLEX® Equine Cytokine/Chemokine Magnetic Bead Panel - Immunology Multiplex Assay
The Equine Inflammation / Immunology Bead-Based Multiplex cytokine Assay kit, using the Luminex xMAP technology, enables the simultaneous analysis of 23 cytokine and chemokine biomarkers in equine serum, plasma and cell culture samples.
About This Item
Polecane produkty
Poziom jakości
reaktywność gatunkowa
horse
producent / nazwa handlowa
Milliplex®
assay range
accuracy: 74%
(IL-17a)
accuracy: 76%
(IL-6)
accuracy: 78%
(FGF-2)
accuracy: 82%
(G-CSF)
accuracy: 83%
(IFNγ)
accuracy: 83%
(IL-12 (p70))
accuracy: 85%
(IL-13)
accuracy: 86%
(IL-10)
accuracy: 88%
(RANTES/CCL5)
accuracy: 89%
(IL-8/CXCL8)
accuracy: 90%
(IL-2)
accuracy: 90%
(MCP-1)
accuracy: 91%
(Fractalkine/CS3CL1)
accuracy: 92%
(IL-5)
accuracy: 93%
(Eotaxin/CCL11)
accuracy: 97%
(GRO)
sensitivity: 1.4 pg/mL
(IL-6)
sensitivity: 10.6 pg/mL
(IL-5)
sensitivity: 13.5 pg/mL
(IL-2)
sensitivity: 15.4 pg/mL
(IL-17A)
sensitivity: 16.3 pg/mL
(FGF-2)
sensitivity: 16.7 pg/mL
(IP-10)
sensitivity: 165 pg/mL
(IFNγ)
sensitivity: 25.3 pg/mL
(IL-18)
sensitivity: 29.3 pg/mL
(IL-1β)
sensitivity: 3.9 pg/mL
(RANTES/CCL5)
sensitivity: 3.94 pg/mL
(GM-CSF)
sensitivity: 340 pg/mL
(G-CSF)
sensitivity: 355 pg/mL
(IL-4)
sensitivity: 39-130 pg/mL
(IL-13)
sensitivity: 39.1 pg/mL
(IL-1α)
sensitivity: 399 ng/mL
(MCP-1)
sensitivity: 457 pg/mL
(Fractalkine/CS3CL1)
sensitivity: 49.2 pg/mL
(IL-12 (p70))
sensitivity: 5.2 pg/mL
(TNFα)
sensitivity: 62.5 pg/mL
(IL-10)
sensitivity: 7.8 pg/mL
(GRO)
sensitivity: 74.3 pg/mL
(IL-8/CXCL8)
sensitivity: 8.3 pg/mL
(Eotaxin/CCL11)
standard curve range: 15-15,000 pg/mL
(IL-17A)
standard curve range: 15-15,000 pg/mL
(IL-2)
standard curve range: 15-15,000 pg/mL
(IL-5)
standard curve range: 15-15,000 pg/mL
(IL-6)
standard curve range: 15-15,000 pg/mL
(IP-10)
standard curve range: 16.3 pg/mL
(FGF-2)
standard curve range: 29-30,000 pg/mL
(IL-1β)
standard curve range: 293-300,000 pg/mL
(IL-4)
standard curve range: 34-35,000 pg/mL
(IL-18)
standard curve range: 340 pg/mL
(G-CSF)
standard curve range: 342-350,000 ng/mL
(MCP-1)
standard curve range: 39-40,000 pg/mL
(IL-12 (p70))
standard curve range: 39-40,000 pg/mL
(IL-13)
standard curve range: 4-4,000 pg/mL
(TNFα)
standard curve range: 457 pg/mL
(Fractalkine/CS3CL1)
standard curve range: 488-500,000 pg/mL
(IFNγ)
standard curve range: 49-50,000 pg/mL
(IL-10)
standard curve range: 5-5,000 pg/mL
(GM-CSF)
standard curve range: 5-5,000 pg/mL
(RANTES/CCL5)
standard curve range: 59-60,000 pg/mL
(IL-1α)
standard curve range: 59-60,000 pg/mL
(IL-8/CXCL8)
standard curve range: 6-6,000 pg/mL
(GRO)
standard curve range: 8.3 pg/mL
(Eotaxin/CCL11)
metody
multiplexing: suitable
metoda wykrywania
fluorometric (Luminex xMAP)
Warunki transportu
ambient
Powiązane kategorie
Opis ogólny
MILLIPLEX® Equine Cytokine/Chemokine Premix Panel is a 23-plex kit used for the simultaneous quantification of any or all the following analytes in equine serum, plasma, or culture supernatant samples: Eotaxin/CCL11, FGF-2, Fractalkine/CS3CL1, G-CSF, GM-CSF, GRO, IFN, IL-1α, IL-1β, IL-2, IL-4, IL-5, IL-6, IL-8/CXCL8, IL-10, IL-12 (p70), IL-13, IL-17a, IL-18, IP-10, MCP-1, RANTES/CCL5 and TNFα. This kit uses a 96-well format, contains a lyophilized standard cocktail, two internal assay quality controls and can measure up to 38 samples in duplicate.
The Luminex® xMAP® platform uses a magnetic bead immunoassay format for ideal speed and sensitivity to quantitate multiple analytes simultaneously, dramatically improving productivity while conserving valuable sample volume.
Panel Type: Cytokines/Chemokines
Specyficzność
Zastosowanie
- Analytes: Eotaxin/CCL11, FGF-2, Fractalkine/CX3CL1, G-CSF, GM-CSF, GRO/KC, IFN-γ, IL-1α, IL-1β, IL-2, IL-4, IL-5, IL-6, IL-8, IL-10, IL-12 (p70), IL-13, IL-17A, IL-18, IP-10 (CXCL10), MCP-1, RANTES (CCL5), TNF-α
- Recommended Sample Type: Equine serum, plasma, tissue culture supernatant or tissue/cell extracts
- Recommended Sample Dilution: 25 μL per well of undiluted serum or plasma; tissue/cell culture samples may require dilution with an appropriate medium
- Assay Run Time: A primary incubation of 2 hours at room temperature (RT) (20-25°C), or for greater sensitivity, overnight (16-18 hours) at 2-8°C; followed by a 1 hour secondary incubation at RT
- Research Category: Inflammation & Immunology
Cechy i korzyści
Opakowanie
Przechowywanie i stabilność
Informacje prawne
Oświadczenie o zrzeczeniu się odpowiedzialności
Hasło ostrzegawcze
Danger
Zwroty wskazujące rodzaj zagrożenia
Zwroty wskazujące środki ostrożności
Klasyfikacja zagrożeń
Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Eye Dam. 1 - Skin Sens. 1 - STOT RE 2
Organy docelowe
Respiratory Tract
Kod klasy składowania
10 - Combustible liquids
Certyfikaty analizy (CoA)
Poszukaj Certyfikaty analizy (CoA), wpisując numer partii/serii produktów. Numery serii i partii można znaleźć na etykiecie produktu po słowach „seria” lub „partia”.
Masz już ten produkt?
Dokumenty związane z niedawno zakupionymi produktami zostały zamieszczone w Bibliotece dokumentów.
Powiązane treści
Discover benefits of using biomarker detection multiplex immunoassays for companion and agricultural animal health research and find vet med multiplex assays.
Discover the benefits of MILLIPLEX® multiplex assays, based on Luminex® xMAP® multiplex assay technology, that provide consistent, high-quality results and see how these multiplex biomarker Luminex® assays are being used to advance research.
Nasz zespół naukowców ma doświadczenie we wszystkich obszarach badań, w tym w naukach przyrodniczych, materiałoznawstwie, syntezie chemicznej, chromatografii, analityce i wielu innych dziedzinach.
Skontaktuj się z zespołem ds. pomocy technicznej