Przejdź do zawartości
Merck
Wszystkie zdjęcia(1)

Kluczowe dokumenty

CVPB52PK1

Millipore

Vitipore® II Plus Cartridge Filter

cartridge nominal length 20 in. (50 cm), filter diam. 6.9 cm (2.7 in.), Code 5 ((2-222) O-rings and spear)

Zaloguj sięWyświetlanie cen organizacyjnych i kontraktowych


About This Item

Kod UNSPSC:
23151806

Materiały

mixed cellulose esters (MCE) prefilter
polypropylene device
polypropylene support
silicone seal

zgodność regionalna

meets EU 1935/2004/EC (alll component materials)
meets FDA 21 CFR 177-182 (all component materials)

Właściwości

hydrophilic

producent / nazwa handlowa

Opticap®

Parametry

≤34.2 mL/min air diffusion at 1.5 bar (22 psig) (in water)
0.35 bar max. differential pressure (5 psid) at 109 °C (Forward)
0.35 bar max. inlet pressure (5 psi) at 109 °C (Forward)
1.7 bar max. differential pressure (25 psid) at 80 °C (Forward)
1.7 bar max. inlet pressure (25 psi) at 80 °C (Forward)
3.5 bar max. differential pressure (50 psid) at 25 °C (Reverse; intermittent)
3.5 bar max. inlet pressure (50 psi) at 25 °C (Reverse; intermittent)
5.5 bar max. differential pressure (80 psid) at 25 °C (Forward)
5.5 bar max. inlet pressure (80 psi) at 25 °C (Forward)

długość nominalna kartridża

20 in. (50 cm)

Rozmiar urządzenia

20 in.

śr. filtra

6.9 cm (2.7 in.)

Powierzchnia filtracyjna filtra

1.56 m2

wielkość porów

0.45 μm pore size

punkt pęcherzykowania

≥1930 mbar (28 psig), air with water

kod wkładu

Code 5 ((2-222) O-rings and spear)

Szukasz podobnych produktów? Odwiedź Przewodnik dotyczący porównywania produktów

Opis ogólny

Cartridge Type: Liquid
Device Configuration: Cartridge

Zastosowanie

Food and Beverage; Beer; Bottled Water; Wine

Uwaga dotycząca przygotowania

Sterilization Method:
100 SIP cycles of 30 min at 109 °C; hot water sanitized 50 times for 30 min at 80 °C maximum
This product was manufactured with a Durapore® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).

Komentarz do analizy

Gravimetric Extractables: &#x2264 51 mg per 10-inch cartridge after 24 hours in water at controlled room temperature.

Inne uwagi

Directions for Use:
  • Organism Retention: Microorganism
  • Mode of Action: Filtration (size exclusion)
  • Application: BioProcessing
  • Intended Use: Reduction or removal of microorganism/bioburden
  • Instructions for Use: Please refer Wetting Instructions for Filter Units with Durapore® Membrane user guide
  • Storage Statement: Store in dry location
  • Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations

Informacje prawne

Durapore is a registered trademark of Merck KGaA, Darmstadt, Germany
OPTICAP is a registered trademark of Merck KGaA, Darmstadt, Germany
VITIPORE is a registered trademark of Merck KGaA, Darmstadt, Germany
Ta strona może zawierać tekst przetłumaczony maszynowo.

Certyfikaty analizy (CoA)

Poszukaj Certyfikaty analizy (CoA), wpisując numer partii/serii produktów. Numery serii i partii można znaleźć na etykiecie produktu po słowach „seria” lub „partia”.

Masz już ten produkt?

Dokumenty związane z niedawno zakupionymi produktami zostały zamieszczone w Bibliotece dokumentów.

Odwiedź Bibliotekę dokumentów

Questions

Reviews

No rating value

Active Filters

Nasz zespół naukowców ma doświadczenie we wszystkich obszarach badań, w tym w naukach przyrodniczych, materiałoznawstwie, syntezie chemicznej, chromatografii, analityce i wielu innych dziedzinach.

Skontaktuj się z zespołem ds. pomocy technicznej