跳转至内容
Merck
所有图片(1)

主要文件

10357

Supelco

AMBERLITE XAD®-2

pkg of 500 g

登录查看公司和协议定价


About This Item

CAS号:
MDL编号:
UNSPSC代码:
23151817
价格与库存信息目前不能提供

Agency

suitable for ASTM® D4861
suitable for EPA Method 10A, Method 23 and OTM-45

表单

beads (small)

包装

pkg of 500 g

技术

HPLC: suitable
LPLC: suitable

表面积

~300 m2/g

基质

styrene-divinylbenzene (macroreticular)

基质活性基团

polymer

粒径

20-60 mesh

孔径

~0.65 mL/g pore volume
90 Å mean pore size

密度

1.02 g/mL at 25 °C (true wet)(lit.)
1.08 g/mL at 25 °C (skeletal)(lit.)

分离技术

reversed phase

储存温度

2-8°C

SMILES字符串

N([C@@H](CCC(=O)OC(C)(C)C)C=O)C(=O)OCC1c2c(cccc2)c3c1cccc3

InChI

1S/C24H27NO5/c1-24(2,3)30-22(27)13-12-16(14-26)25-23(28)29-15-21-19-10-6-4-8-17(19)18-9-5-7-11-20(18)21/h4-11,14,16,21H,12-13,15H2,1-3H3,(H,25,28)/t16-/m0/s1

InChI key

BCIPGSZQUDLGSY-INIZCTEOSA-N

正在寻找类似产品? 访问 产品对比指南

一般描述

Amberlite XAD-2是苯乙烯-二乙烯基苯树脂的疏水共聚物,需要较长的纯化过程,可用作吸附剂。Amberlite XAD-2 树脂,依据其疏水基团的芳香性和大小,通过低能的物理相互作用吸附有机化合物。[1]
非离子型大网格树脂,通过疏水性和极性相互作用来完成离子吸附与解吸;通常用于等度条件下。
规格:

应用

Amberlite XAD®-2用作:
  • Soxhlat萃取技术提取有机氯化合物的吸附剂[1]
  • 在高效液相色谱分析柱相层析提取粘附样本的吸附剂[2]
  • 层析吸附剂[3]
用于分子量高达 20,000 的疏水性化合物的多环芳烃吸附剂树脂,具体用途包括酚类和有机物的去除,表面活性剂、芳香化合物和抗生素的回收。可用作催化或金属去除的助剂。经整理的美国环保局版本请参见 Supelpak-2 和 Supelpak-2B。
     

法律信息

ASTM is a registered trademark of American Society for Testing and Materials
Amberlite is a trademark of DuPont de Nemours, Inc.
XAD is a registered trademark of The Dow Chemical Company or an affiliated company of Dow

相关产品

产品编号
说明
价格

储存分类代码

11 - Combustible Solids

WGK

WGK 3

闪点(°F)

Not applicable

闪点(°C)

Not applicable

个人防护装备

Eyeshields, Gloves, type N95 (US)


历史批次信息供参考:

分析证书(COA)

Lot/Batch Number

没有发现合适的版本?

如果您需要特殊版本,可通过批号或批次号查找具体证书。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

M Tamura et al.
The Journal of biological chemistry, 260(17), 9672-9677 (1985-08-15)
Na+,K+-ATPase inhibitors have been found to exist in acutely saline-infused hog plasma, which also inhibit the specific binding of ouabain to Na+,K+-ATPase and the binding of digoxin to specific anti-digoxin antibody. Two of these inhibitors were purified by a combination
Trapping efficiency of polyurethane foam and Amberlite XAD-2 for various organochlorine compounds
Nerin, C., et al.
Fresenius Journal of Analytical Chemistry, 352, 609-611 (1995)
I Martos et al.
Journal of agricultural and food chemistry, 48(5), 1498-1502 (2000-05-23)
European Eucalyptus honeys showed a common and characteristic HPLC profile in which the flavonoids myricetin (3,5,7,3',4', 5'-hexahydroxyflavone), tricetin (5,7,3',4',5'-pentahydroxyflavone), quercetin (3,5,7,3',4'-pentahydroxyflavone), luteolin (5,7,3', 4'-tetrahydroxyflavone), and kaempferol (3,5,7, 4'-tetrahydroxyflavone) were identified. Their contents, and relative amounts, in the analyzed honey samples
Tim J Causon et al.
Journal of chromatography. A, 1217(21), 3519-3524 (2010-04-21)
Alternative approaches to conventional acetonitrile gradient methods for reversed-phase liquid chromatographic analysis of intact proteins have been investigated using commercial poly(styrene-co-divinylbenzene) monolithic columns (Dionex ProSwift RP-2H and RP-4H). Alternative solvents to acetonitrile (2-propanol and methanol) coupled with elevated temperatures demonstrated
Mario Vincenzo Russo et al.
Analytical and bioanalytical chemistry, 404(5), 1517-1527 (2012-07-05)
This paper shows an analytical methodology based on solid-phase extraction by XAD-2 adsorbent and gas chromatography (GC) coupled with nitrogen-phosphorus (NPD) and ion-trap mass spectrometry detectors (ITMS) in negative chemical ionization (NCI) mode analyses for investigating organophosphorus pesticides (OPs) at

相关内容

低压液相色谱(LPLC)在低压下运行,通过泵作用将流动相输送到色谱柱上。

Low pressure liquid chromatography (LPLC) operates at low pressures, using a pump to drive the mobile phase onto the column.

Low pressure liquid chromatography (LPLC) operates at low pressures, using a pump to drive the mobile phase onto the column.

Low pressure liquid chromatography (LPLC) operates at low pressures, using a pump to drive the mobile phase onto the column.

查看所有结果

Questions

1–7 of 7 Questions  
  1. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf

      Helpful?

  2. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

  3. What is the most approriate protocol to wash Amberlite before use? Thanks in advance!

    1 answer
    1. Amberlite XAD-2 is a crude preparation and must be thoroughly cleaned prior to use.

      1. Rinse with hot deionized water (may hold in nylon filter cloth to retain particles) - use at least 3 bed volumes per hour at 110 deg C
      2. Soak overnight in 2 bed volumes (BV) of ethanol.
      3. Load resin into a glass column and rinsed with a further 2 BV of ethanol.
      4. Rinse with 2 BV of deionized water to remove the ethanol, 1 BV of 4% (w/v) sodium hydroxide, 2 BV of deionized water, 1 BV 4% (v/v) hydrochloric acid, and finally rinse with deionized water until the pH of the eluent is neutral.

      For further use it is advantageous to do a wash in the same solvent use in the application.
      Store in sealed container; may be refrigerated but NOT frozen. As a bacteriostat, one may rinse with 20% ethanol (deionized water) prior to storage.

      Helpful?

  4. What is the Department of Transportation shipping information for this product?

    1 answer
    1. Transportation information can be found in Section 14 of the product's (M)SDS.To access the shipping information for this material, use the link on the product detail page for the product.

      Helpful?

  5. Do you offer a precleaned Amberlite XAD-2?

    1 answer
    1. Yes.  Supelco cleans Amberlite XAD2 for a variety of environmental applications.

      Helpful?

  6. May I purchase Amberlite XAD-2 in large quantities?

    1 answer
    1. The largest package size of Amberlite XAD2 is 25 kg (Product No. 3025-U).

      Helpful?

  7. Is Amberlite XAD-2 ready-to-use?

    1 answer
    1. No.  Amberlite XAD2 is shipped imbibed with 5% NaCl & 1% NaCO3; it has not been specially processed nor cleaned. We suggest that it be extensively treated to a suitable preliminary elution and wash.

      Helpful?

Reviews

No rating value

Active Filters

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系技术服务部门