Live/Dead Cell Double Staining Kit

suitable for fluorescence

동의어(들):

Staining kit for live/dead cells

로그인조직 및 계약 가격 보기

크기 선택

1 KIT
₩2,083,085

₩2,083,085


예상 입고일2025년 4월 29일세부사항


벌크 견적 요청

크기 선택

보기 변경
1 KIT
₩2,083,085

About This Item

UNSPSC 코드:
12161503
NACRES:
NA.32

₩2,083,085


예상 입고일2025년 4월 29일세부사항


벌크 견적 요청

적합성

suitable for fluorescence

Quality Level

저장 온도

−20°C

애플리케이션

The Live/Dead Cell Double Staining Kit is utilized for simultaneous fluorescence staining of viable and dead cells. This kit contains calcein-AM and propidium iodide (PI) solutions, which stain viable and dead cells, respectively. Calcein-AM, acetoxymethyl ester of calcein, is highly lipophilic and cell membrane permeable. Though calcein-AM itself is not a fluorescent molecule, the calcein generated from Calcein-AM by esterase in a viable cell emits a strong green fluorescence (λex 490 nm, λem 515 nm). Therefore, calcein-AM only stains viable cells. Alternatively, the nuclei staining dye PI cannot pass through a viable cell membrane. It reaches the nucleus by passing through disordered areas of dead cell membrane, and intercalates with the DNA double helix of the cell to emit red fluorescence (λex 535 nm, λem 617 nm). Since both calcein and PI-DNA can be excited with 490 nm light, simultaneous monitoring of viable and dead cells is possible with a fluorescence microscope. Using λex 545 nm, only dead cells can be observed.

키트 구성품 전용

제품 번호
설명

  • Solution A (Calcein AM solution) 4 × 50

  • Solution B (propidium iodide solution) 300 μL

관련 제품

제품 번호
설명
가격

Storage Class Code

10 - Combustible liquids

WGK

WGK 2

Flash Point (°F)

185.0 °F - closed cup

Flash Point (°C)

85 °C - closed cup


가장 최신 버전 중 하나를 선택하세요:

시험 성적서(COA)

Lot/Batch Number

적합한 버전을 찾을 수 없으신가요?

특정 버전이 필요한 경우 로트 번호나 배치 번호로 특정 인증서를 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

T Kimura et al.
Neuroscience letters, 208(1), 53-56 (1996-04-12)
The recent immunological demonstration of advanced glycation end products (AGE) of the Maillard reaction in several human tissues suggests a possible involvement of AGE in the aging process. We previously prepared a monoclonal anti-AGE antibody (6D12) which recognized N epsilon-(carboxymethyl)lysine.
Carolina Fracalossi Rediguieri et al.
Journal of biomaterials science. Polymer edition, 28(16), 1918-1934 (2017-07-25)
The growing area of tissue engineering has the potential to alleviate the shortage of tissues and organs for transplantation, and electrospun biomaterial scaffolds are extremely promising devices for translating engineered tissues into a clinical setting. However, to be utilized in
Camille Raillon et al.
Cytometry. Part A : the journal of the International Society for Analytical Cytology, 95(10), 1085-1095 (2019-08-01)
The isolation, analysis, and enumeration of circulating tumor cells (CTCs) from cancer patient blood samples are a paradigm shift for cancer patient diagnosis, prognosis, and treatment monitoring. Most methods used to isolate and enumerate these target cells rely on the
Amin Hassanzadeh-Barforoushi et al.
Lab on a chip, 18(15), 2156-2166 (2018-06-21)
We present here a new method to easily and reliably generate an array of hundreds of dispersed nanoliter-volume semi-droplets for single-cells culture and analysis. The liquid segmentation step occurs directly in indexed traps by a tweezer-like mechanism and is stabilized
S Yoshida et al.
Clinical nephrology, 49(5), 273-280 (1998-06-09)
Cardiovascular disease is one of the most common complications of dialysis and renal transplant patients, and high levels of AGE are present in end-stage renal failure. To address the potential involvement of AGE and growth factors in the pathophysiology of

문서

암, 신경과학, 줄기 세포 연구 응용분야를 위한 세포 증식(BrdU, MTT, WST1), 세포 생존성, 세포 독성 실험용 세포 기반 분석법.

Cell based assays for cell proliferation (BrdU, MTT, WST1), cell viability and cytotoxicity experiments for applications in cancer, neuroscience and stem cell research.

질문

1–3 / 3 질문  
  1. Can this kit be used to assess cell viability within bacterial biofilms?

    1 답변
    1. This product requires preparation of a cell suspension and has not been validated for bacterial biofilms or cells attached to any surface.

      도움이 되었습니까?

  2. Can the live/dead double staining kit be used on fixed cells?

    1 답변
    1. The kit is not designed for use with just dead cells. When cells are fixed, it typically results in cell death for all cells. Consequently, if all the cells are dead, it is expected that the Calcein AM would not be able to enter the cells, as Calcein AM is not a fluorescent molecule. The available data sheet states, "While the cells are viable, the calcein generated from CalceinAM by esterase in a viable cell emits strong green fluorescence (excitation: 490 nm, emission: 515 nm)." Therefore, Calcein-AM only stains viable cells. If all the cells are dead, the only observed staining will be from the Propidium Iodide - which is the dead cell stain reagent in kit 04511.
      If the cells are stained while viable, it is possible to image the cells after they have been fixed in paraformaldehyde or other fixatives. Although this is a common practice in some laboratories, It's suggested to consider a 10-minute fixation instead of 30 minutes, as fixing for 30 minutes may not be advisable.

      도움이 되었습니까?

  3. How many assays or tests can be conducted using one kit of PN: 04511-1KT-F?

    1 답변
    1. The 04511 kit consists of 2 components, with reagent B being the limiting reagent, requiring just 300 microliters of reagent. To prepare the staining solution, 10 microliters of Reagent A and 5 microliters of Reagent B are mixed with 5 ml of PBS. Each test necessitates 100 microliters of the staining solution. With 5 microliters of Reagent B being sufficient for 50 tests, 300 microliters of Reagent B is adequate for 60 batches of the staining reagent, resulting in 3000 tests (50 x 60). Although the maximum number of specimens might not always be stained in practice, the kit theoretically should allow for 3000 tests.