추천 제품
Agency
APHA
ISO 11290
Quality Level
규정 준수
FDA (BAM)
양식
medium granules (dehydrated (DCM))
제조업체/상표
ChromoCult®
기술
microbiological culture: suitable
pH
7.0-7.4 (25 °C, 70 g/L in H2O)
solubility
70 g/L
응용 분야
food and beverages
microbiology
저장 온도
15-25°C
적합성
Listeria spp.
일반 설명
애플리케이션
분석 메모
Appearance (clearness): slightly opalescent to opalescent
pH-value (25 °C): 7.0 - 7.4
Growth promotion test in accordance with the current version of DIN EN ISO 11133.
Inoculum on reference medium (Listeria monocytogenes ATCC 13932 (WDCM 00021)):
Colony count (Listeria monocytogenes ATCC 13932 (WDCM 00021)):
Recovery on test medium (Listeria monocytogenes ATCC 13932 (WDCM 00021)): ≥ 50 %
Colonies (Listeria monocytogenes ATCC 13932 (WDCM 00021)): blue green colonies with opaque halo
Inoculum on reference medium (Listeria monocytogenes ATCC 35152 (WDCM 00109)):
Colony count (Listeria monocytogenes ATCC 35152 (WDCM 00109)):
Recovery on test medium (Listeria monocytogenes ATCC 35152 (WDCM 00109)): ≥ 50 %
Colonies(Listeria monocytogenes ATCC 35152 (WDCM 00109)): blue green colonies with opaque halo
Growth (Listeria innocua ATCC 33090 (WDCM 00017)): no limit
Colonies (Listeria innocua ATCC 33090 (WDCM 00017)): blue green colonies without opaque halo
Growth (Escherichia coli ATCC 8739 (WDCM 00012)): total inhibition
Growth (Escherichia coli ATCC 25922 (WDCM 00013)): total inhibition
Growth (Enterococcus faecalis ATCC 19433 (WDCM 00009)): total inhibition
Growth (Enterococcus faecalis ATCC 29212 (WDCM 00087)): total inhibition
Incubation: 44 ± 4 hours at 37 ± 1 °C
Reference media: Tryptic Soy Agar
A recovery rate of 50 % is equivalent to a productivity value of 0.5.
The indicated colony counts result from the sum of a triple determination.
법적 정보
신호어
Warning
유해 및 위험 성명서
Hazard Classifications
Eye Irrit. 2 - Skin Irrit. 2 - Skin Sens. 1
Storage Class Code
11 - Combustible Solids
WGK
WGK 3
시험 성적서(COA)
제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.
문서
Detection of Listeria monocytogenes in food and environmental samples according to ISO 11290-1, FDA-BAM and USDA-FSIS
Water source comparison for microbiological media preparation highlights central purification vs. Milli-Q® IX system efficiency.
Selective media enable faster results and visual confirmation for the detection, identification, and enumeration of microorganisms
프로토콜
Listeria is a public health concern, affecting elderly, pregnant, newborns, and immunocompromised individuals.
활성 필터
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..