コンテンツへスキップ
Merck

A0561

Sigma-Aldrich

ACCUSPIN System-Histopaque®-1077

sterile-filtered, density: 1.077 g/mL

ログイン組織・契約価格を表示する


About This Item

MDL番号:
UNSPSCコード:
12352207
NACRES:
NA.75

無菌性

aseptically filled

形状

solution

シェルフライフ

Expiry date on the label.

包装

package of 100 tubes

密度

1.077 g/mL

アプリケーション

hematology
histology

保管温度

2-8°C

類似した製品をお探しですか? 訪問 製品比較ガイド

詳細

ACCUSPIN System-Histopaque-1077 products are intended for use in the isolation of lymphocytes and other mononuclear cells. The separation medium, Histopaque-1077, is a sterile-filtered, endotoxin-tested solution of polysucrose and sodium diatrizoate, adjusted to a density of 1.077 g/mL. ACCUSPIN System-HISTOPAQUE-1077 employs γ-irradiated 50 mL polypropylene centrifuge tubes specially designed with two chambers separated by a porous high-density polyethylene barrier ("frit"). Each tube is aseptically filled with 15 mL of Histopaque 1077. Each tube will separate 15-30 mL of anticoagulated blood.

アプリケーション

ACCUSPIN System-Histopaque-1077 is used for the separation of lymphocytes and other mononuclear cells from whole blood and bone marrow using density gradient separation media. Histopaque-1077 has been used for:

  • human lymphocyte antigen (HLA) typing
  • initial isolation step prior to the enumeration of T, B, and ‘null’ lymphocytes.
  • preparation of pure lymphocyte suspensions for cell culture and cytotoxicity assays.
  • isolation and purification of peripheral blood mononuclear cells (PBMCs) and bone marrow mononuclear cells (BMMCs)citation
  • isolation of human lymphocytescitation
  • isolation of breast cancer circulating tumor cells (CTCs) from the whole bloodcitation
ACCUSPIN System-HISTOPAQUE-1077には、特別にデザインされた遠心チューブを使用しており、このチューブには多孔質高密度ポリエチレンバリア(「フリット」)によって区切られた2つのチャンバーがあります。下のチャンバーにはHISTOPAQUE-1077が入っており、分離媒体と混ざるおそれなしに、抗凝固剤を添加した血液を入れることができます。遠心分離すると、全血はフリットを通ってその下のHISTOPAQUE-1077と接触し、血液成分が明確に分離されます。赤血球が凝集し、顆粒球が若干高張になることで沈降速度が上昇し、その結果、ACCUSPINチューブの底に沈殿します。リンパ球をはじめとする単核細胞、すなわち単球は、血漿とHISTOPAQUE-1077の界面に保持されます。

特徴および利点

ACCUSPIN System-Histopaque®-1077 offers numerous advantages, such as:
  • Optimal recovery of viable cells
  • Permits selective separation of blood cell types
  • Prevents cell distortion
  • Preserves cell viability
  • Minimal extraneous cell interference
  • Reproducible performance from batch to batch
  • Histopaque is sterile-filtered and endotoxin-tested
  • Stable at 2-8°C for at least 2 years when protected from light

原理

The lower chamber contains HISTOPAQUE-1077 which allows the addition of anticoagulated whole blood without risk of mixing with the separation medium. On centrifugation, the whole blood descends through the frit to contact with the HISTOPAQUE-1077 below the frit, giving a clear separation of the blood components. The erythrocytes aggregate and the granulocytes become slightly hypertonic, increasing their sedimentation rate, resulting in pelleting at the bottom of the ACCUSPIN tube. Lymphocytes and other mononuclear cells, i.e., monocytes, remain at the plasma-HISTOPAQUE-1077 interface.

法的情報

Accuspin is a trademark of Sigma-Aldrich Co. LLC
Histopaque is a registered trademark of Merck KGaA, Darmstadt, Germany

ピクトグラム

Health hazard

シグナルワード

Danger

危険有害性情報

危険有害性の分類

Resp. Sens. 1 - Skin Sens. 1

保管分類コード

12 - Non Combustible Liquids

WGK

WGK 3

引火点(°F)

Not applicable

引火点(℃)

Not applicable

個人用保護具 (PPE)

Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter


適用法令

試験研究用途を考慮した関連法令を主に挙げております。化学物質以外については、一部の情報のみ提供しています。 製品を安全かつ合法的に使用することは、使用者の義務です。最新情報により修正される場合があります。WEBの反映には時間を要することがあるため、適宜SDSをご参照ください。

労働安全衛生法名称等を表示すべき危険物及び有害物

名称等を表示すべき危険物及び有害物

労働安全衛生法名称等を通知すべき危険物及び有害物

名称等を通知すべき危険物及び有害物

Jan Code

A0561-100X15ML:4548173359281
A0561-15ML:
A0561-VAR:
A0561-BULK:


試験成績書(COA)

製品のロット番号・バッチ番号を入力して、試験成績書(COA) を検索できます。ロット番号・バッチ番号は、製品ラベルに「Lot」または「Batch」に続いて記載されています。

以前この製品を購入いただいたことがある場合

文書ライブラリで、最近購入した製品の文書を検索できます。

文書ライブラリにアクセスする

この製品を見ている人はこちらもチェック

Janet C Lindow et al.
PLoS neglected tropical diseases, 6(7), e1742-e1742 (2012-07-21)
The four dengue virus serotypes (DENV-1-DENV-4) have a large impact on global health, causing 50-100 million cases of dengue fever annually. Herein, we describe the first kinetic T cell response to a low-dose DENV-1 vaccination study (10 PFU) in humans.
Tiffany A Greenwood et al.
PloS one, 7(1), e29630-e29630 (2012-01-19)
While it is clear that schizophrenia is highly heritable, the genetic basis of this heritability is complex. Human genetic, brain imaging, and model organism studies have met with only modest gains. A complementary research tactic is to evaluate the genetic
Nicolas Antoine-Moussiaux et al.
PloS one, 4(5), e5728-e5728 (2009-05-30)
In a recent study dealing with a mouse model of Trypanosoma evansi-associated disease, a remarkable synchrony between the parasitaemia peak and the white-blood-cell count nadir was noticed. The present study was designed to establish whether there is a direct causal

ライフサイエンス、有機合成、材料科学、クロマトグラフィー、分析など、あらゆる分野の研究に経験のあるメンバーがおります。.

製品に関するお問い合わせはこちら(テクニカルサービス)