おすすめの製品
由来生物
mouse
品質水準
抗体製品の状態
ascites fluid
抗体製品タイプ
primary antibodies
クローン
4B7B2, monoclonal
化学種の反応性
mouse, human
テクニック
ELISA: suitable
flow cytometry: suitable
immunohistochemistry: suitable
western blot: suitable
アイソタイプ
IgG1
UniProtアクセッション番号
輸送温度
wet ice
ターゲットの翻訳後修飾
unmodified
遺伝子情報
human ... BMPR1A(657)
関連するカテゴリー
詳細
BMPR-1A (bone morphogenic protein receptor type 1A) signaling is known to be important for inner root sheath differentiation, hair follicle cycling and tooth development. Mutations in BMPR-1A are a common cause of juvenile polyposis syndrome (JPS). BMPR-1A is expressed in a high quantity during the formation of the primary and secondary palate and the loss of BMPR-1A could be a cause for the cleft palate birth defect.
免疫原
Purified recombinant fragment of human BMPR1A expressed in E. Coli
アプリケーション
Research Category
細胞シグナル伝達
細胞シグナル伝達
Research Sub Category
発生シグナル伝達
発生シグナル伝達
Immunohistochemistry Analysis: A 1:200-1,000 dilution from a representative lot detected BMPR-1A in colon cancer and kidney tissues.
Flow Cytometry Analysis: A 1;200-400 dilution from a representative lot detected BMPR-1A in HeLa cells.
ELISA: A representative lot detected control Antigen (100 ng) and Antigen (10 ng, 50 ng, 100 ng) in ELISA (Direct).
Flow Cytometry Analysis: A 1;200-400 dilution from a representative lot detected BMPR-1A in HeLa cells.
ELISA: A representative lot detected control Antigen (100 ng) and Antigen (10 ng, 50 ng, 100 ng) in ELISA (Direct).
This Anti-BMPR-1A, clone 4B7B2 Antibody is validated for use in western blotting, IHC, flow cytometry & ELISA for the detection of BMPR-1A.
品質
Evaluated by Western Blotting in PC-3, K562 and mouse liver lysates.
Western Blotting Analysis: A 1:500-2,000 dilution of this antibody detected BMPR-1A in PC-3, K562 and mouse liver lysates.
Western Blotting Analysis: A 1:500-2,000 dilution of this antibody detected BMPR-1A in PC-3, K562 and mouse liver lysates.
ターゲットの説明
~65 kDa observed. Uncharacterized bands may be observed in some lysate(s).
物理的形状
Unpurified
Mouse monoclonal IgG1 ascitic fluid containing up to 0.1% sodium azide.
保管および安定性
Stable for 1 year at -20°C from date of receipt.
Handling Recommendations: Upon receipt and prior to removing the cap, centrifuge the vial and gently mix the solution. Aliquot into microcentrifuge tubes and store at -20°C. Avoid repeated freeze/thaw cycles, which may damage IgG and affect product performance.
Handling Recommendations: Upon receipt and prior to removing the cap, centrifuge the vial and gently mix the solution. Aliquot into microcentrifuge tubes and store at -20°C. Avoid repeated freeze/thaw cycles, which may damage IgG and affect product performance.
免責事項
Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.
Not finding the right product?
Try our 製品選択ツール.
保管分類コード
12 - Non Combustible Liquids
WGK
nwg
引火点(°F)
Not applicable
引火点(℃)
Not applicable
適用法令
試験研究用途を考慮した関連法令を主に挙げております。化学物質以外については、一部の情報のみ提供しています。 製品を安全かつ合法的に使用することは、使用者の義務です。最新情報により修正される場合があります。WEBの反映には時間を要することがあるため、適宜SDSをご参照ください。
Jan Code
MABS419:
試験成績書(COA)
製品のロット番号・バッチ番号を入力して、試験成績書(COA) を検索できます。ロット番号・バッチ番号は、製品ラベルに「Lot」または「Batch」に続いて記載されています。
ライフサイエンス、有機合成、材料科学、クロマトグラフィー、分析など、あらゆる分野の研究に経験のあるメンバーがおります。.
製品に関するお問い合わせはこちら(テクニカルサービス)