Passa al contenuto
Merck
  • Fast agitated directly suspended droplet microextraction technique for the rapid analysis of eighteen organophosphorus pesticides in human blood.

Fast agitated directly suspended droplet microextraction technique for the rapid analysis of eighteen organophosphorus pesticides in human blood.

Journal of chromatography. A (2014-12-30)
Rupender Kumari, Devendra K Patel, Smita Panchal, Rakesh R Jha, G N V Satyanarayana, Ankita Asati, Nasreen G Ansari, Manoj K Pathak, C Kesavachandran, Ramesh C Murthy
ABSTRACT

A new sample preparation technique named as fast agitated directly suspended droplet microextraction (FA-DSDME) was proposed as an improved version of directly suspended droplet microextraction (DSDME) for the extraction and pre-concentration of wide-range organophosphorus pesticides (OPPs) from human blood prior to liquid chromatography tandem mass spectrometric (LC-MS/MS) analysis. In this method, instead of protecting the unwanted rupturing of extraction droplet (organic solvent), it was deliberately splintered into fine droplets by providing automated high-speed agitation to the biphasic extraction system (extraction solvent and sample solution). Fine organic droplets were then recollected into one, not by using a centrifuge machine but just by giving a very slow stirring to the bottom of the extraction system. The present method has surmounted the problem of prolonged extraction time associated with old DSDME. Under optimum extraction conditions, the method showed good sensitivity with low detection limits ranging from 0.0009 to 0.122μgL(-1). Mean recoveries were achieved in the range of 86-109% at three levels of spiking concentration (low, middle and high) from linearity range of individual analyte. Intra-day and inter-day precisions were ≤4.68 and ≤9.57 (%RSD) respectively. Enrichment factor (EF) for each analyte varied from 30 to 132 which prove the ability of this technique to pre-concentrate the extracted analytes up to a good extent. The sample matrices have shown an insignificant influence on method's sensitivity. The proposed method may find immense use in epidemiological, toxicological, regulatory and forensic laboratories.

MATERIALI
N° Catalogo
Marchio
Descrizione del prodotto

Sigma-Aldrich
Metanolo, suitable for HPLC, ≥99.9%
Sigma-Aldrich
Metanolo, ACS reagent, ≥99.8%
Sigma-Aldrich
Metanolo, HPLC Plus, ≥99.9%
Sigma-Aldrich
Metanolo, suitable for HPLC, gradient grade, suitable as ACS-grade LC reagent, ≥99.9%
Sigma-Aldrich
Metanolo, Laboratory Reagent, ≥99.6%
Sigma-Aldrich
Metanolo, BioReagent, ≥99.93%
Sigma-Aldrich
Metanolo, Absolute - Acetone free
Sigma-Aldrich
Metanolo, ACS spectrophotometric grade, ≥99.9%
Sigma-Aldrich
Metanolo, ACS reagent, ≥99.8%
Sigma-Aldrich
Esadecano, ReagentPlus®, 99%
USP
Metanolo, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
1-Dodecanol, reagent grade, 98%
Sigma-Aldrich
1-Dodecanol, ACS reagent, ≥98.0%
Sigma-Aldrich
Metanolo, ACS reagent, ≥99.8%
Supelco
Metanolo, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Paraoxon-ethyl, ≥90%, oil
Sigma-Aldrich
Lauryl alcohol, ≥98%, FG
Sigma-Aldrich
1-Undecanol, 97%
Supelco
Chlorpyrifos, PESTANAL®, analytical standard
Supelco
Metanolo, analytical standard
Supelco
Malathion, PESTANAL®, analytical standard
Sigma-Aldrich
Esadecano, anhydrous, ≥99%
Supelco
Dichlorvos, PESTANAL®, analytical standard
Supelco
Esadecano, analytical standard
Sigma-Aldrich
Metanolo, NMR reference standard
Supelco
Dimethoate, PESTANAL®, analytical standard
Supelco
Chlorpyrifos, certified reference material, TraceCERT®, Manufactured by: Sigma-Aldrich Production GmbH, Switzerland
Sigma-Aldrich
2-Dodecanol, 99%
Sigma-Aldrich
Undecyl alcohol, 97%, FG
Supelco
Quinalphos, PESTANAL®, analytical standard