Passa al contenuto
Merck

Percutaneous bone lesion ablation.

La Radiologia medica (2014-06-05)
Dimitrios K Filippiadis, Sean Tutton, Alexis Kelekis
ABSTRACT

Benign tumors and metastatic bone lesions can be treated by ablation techniques performed either alone or in combination with other percutaneous techniques. Ablation techniques include ethanol or acetic acid injection and thermal ablation by means of energy deposition [including laser, radiofrequency, microwave, cryoablation, radiofrequency ionization and magnetic resonance (MR)-guided high-intensity focused ultrasound (HIFU)]. Goal definition of the therapy is crucial: ablation techniques can be proposed as curative treatments in benign bone tumors or oligometastatic disease (<3 lesions). Alternatively, these techniques can be proposed as palliative treatments aiming at reduction of pain, local control of the disease and tumor decompression. Depending on the lesion's location ablation can be combined with cementation with or without further metallic augmentation; local tumor control can be enhanced by combining ablation with transarterial bland embolization or chemoembolization. Thermal ablation of bone and soft tissues is characterized by high success and relatively low rates of potential complications, mainly iatrogenic thermal damage of surrounding sensitive structures. Successful thermal ablation requires a sufficient ablation volume and thermal protection of the surrounding vulnerable structures. This article will describe the general principles governing ablation and the mechanism of action for each technique and in addition will review the literature about safety and effectiveness of percutaneous imaging-guided ablation for benign and malignant (primary and metastatic) lesions.

MATERIALI
N° Catalogo
Marchio
Descrizione del prodotto

Sigma-Aldrich
Ethyl alcohol, Pure, 200 proof, ACS reagent, ≥99.5%
Sigma-Aldrich
Acido acetico, glacial, ACS reagent, ≥99.7%
Sigma-Aldrich
Acido acetico, glacial, ReagentPlus®, ≥99%
Sigma-Aldrich
Ethyl alcohol, Pure, 200 proof, meets USP testing specifications
Sigma-Aldrich
Ethyl alcohol, Pure, 190 proof, for molecular biology
Sigma-Aldrich
Acido acetico, glacial, ≥99.99% trace metals basis
Sigma-Aldrich
Acido acetico, suitable for HPLC
Sigma-Aldrich
Acido acetico, for luminescence, BioUltra, ≥99.5% (GC)
Sigma-Aldrich
Etanolo, BioUltra, for molecular biology, ≥99.8%, (absolute alcohol, without additive, A15 o1)
USP
Acido acetico, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
Acido acetico, ≥99.5%, FCC, FG
Sigma-Aldrich
Acido acetico, natural, ≥99.5%, FG
Sigma-Aldrich
Etanolo, purum, fine spirit, denaturated with 4.8% methanol, F25 METHYL1, ~96% (based on denaturant-free substance)
Supelco
Ethanol-50, 50 mg/dL in H2O, ampule of 10 × 1.2 mL, certified reference material, Cerilliant®
Supelco
Ethanol solution, certified reference material, 2000 μg/mL in methanol
Supelco
Ethanol-80, 80 mg/dL in H2O, ampule of 10 × 1.2 mL, certified reference material, Cerilliant®
Supelco
Ethanol-10, 10 mg/dL in H2O, pack of 10 × 1.2 mL ampules, certified reference material, Cerilliant®
Supelco
Ethanol-100 (10 ampules/kit), 100 mg/dL in H2O, ampule of 10 × 1.2 mL, certified reference material, Cerilliant®
Supelco
Ethanol-500, 500 mg/dL in H2O, ampule of 10 × 1.2 mL, certified reference material, Cerilliant®
Supelco
Ethanol-300, 300 mg/dL in H2O, ampule of 10 × 1.2 mL, certified reference material, Cerilliant®
Sigma-Aldrich
Etanolo, purum, absolute ethanol, denaturated with 2% 2-butanone, A15 MEK1, ≥99.8% (based on denaturant-free substance)
Sigma-Aldrich
Etanolo, purum, fine spirit, denaturated with 2% 2-butanone, F25 MEK1, ~96% (based on denaturant-free substance)
Supelco
Ethanol-150, 150 mg/dL in H2O, ampule of 10 × 1.2 mL, certified reference material, Cerilliant®
USP
Etanolo, United States Pharmacopeia (USP) Reference Standard
Supelco
Acido acetico, analytical standard
Supelco
Ethanol-200 (10 ampules/kit), 200 mg/dL in H2O, ampule of 10 × 1.2 mL, certified reference material, Cerilliant®
Supelco
Etanolo, standard for GC
Supelco
Ethanol Calibration Kit, ampule of 10 × 1.2 mL, certified reference material, Cerilliant®
Sigma-Aldrich
Reagent Alcohol, anhydrous, ≤0.003% water
Supelco
Ethanol-25, 25 mg/dL in H2O, ampule of 10 × 1.2 mL, certified reference material, Cerilliant®