29799-U
SLB®-ILPAH Capillary GC Column
L × I.D. 20 m × 0.18 mm, df 0.05 μm
Scegli un formato
626,00 €
Scegli un formato
About This Item
626,00 €
Prodotti consigliati
Materiali
fused silica
Livello qualitativo
Parametri
≤25-300 °C temperature (isothermal or programmed)
Beta
900
df
0.05 μm
tecniche
gas chromatography (GC): suitable
Lungh. × D.I.
20 m × 0.18 mm
Gruppo funzionale matrice
Non-bonded; 1,12-di(tripropylphosphonium)dodecane bis(trifluoromethanesulfonyl)imide phase
applicazioni
food and beverages
Tipo di colonna
capillary polar
Cerchi prodotti simili? Visita Guida al confronto tra prodotti
Categorie correlate
Descrizione generale
USP Code: None
Phase: Non-bonded; 1,12-Di(tripropylphosphonium)dodecane bis(trifluoromethanesulfonyl)imide
Temp. Limits: Subambient to 300 °C (isothermal or programmed)
Applicazioni
This study investigates the retention behavior of polycyclic aromatic sulfur heterocycles (PASHs) using gas chromatography with different stationary phases, including ionic liquids (ILs). The IL phase demonstrated unique selectivity and correlation with PASH geometry. (Wilson, Lee, et al, 2017)
https://doi.org/10.1016/j.chroma.2017.01.026
Retention behavior of isomeric polycyclic aromatic sulfur heterocycles in gas chromatography on stationary phases of different selectivity
The research evaluates the gas chromatographic retention indices of alkyl-substituted PASHs using various stationary phases, including ionic liquids. Results indicate that ILs offer distinct selectivity and thermal stability, enhancing the separation of complex mixtures.
(Wilson, Lee, et al, 2017)
https://doi.org/10.1016/j.chroma.2017.01.024
Ultra-high thermal stability perarylated ionic liquids as gas chromatographic stationary phases for the selective separation of polyaromatic hydrocarbons and polychlorinated biphenyls
This article explores the use of perarylated ionic liquids as stationary phases in gas chromatography for separating polycyclic aromatic hydrocarbons and polychlorinated biphenyls. The ILs exhibit high thermal stability and unique selectivity, improving the resolution of challenging analytes.
(Anderson & Davis, 2019)
https://doi.org/10.1016/j.chroma.2
Note legali
Codice della classe di stoccaggio
11 - Combustible Solids
Classe di pericolosità dell'acqua (WGK)
WGK 3
Punto d’infiammabilità (°F)
Not applicable
Punto d’infiammabilità (°C)
Not applicable
Scegli una delle versioni più recenti:
Possiedi già questo prodotto?
I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.
Articoli
Compare PAH determination in olive oil: traditional GB 5009.265-2021 method vs. faster, simpler SPE with Supelclean™ EZ-POP NP; both meet criteria.
Protocolli
Ionic liquid capillary GC columns enhance polar analyte inertness, addressing challenges in chromatography with improved stationary phases.
Filtri attivi
Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..
Contatta l'Assistenza Tecnica.