The protocol for cell samples using MAK434 is as follows:
- Suspend about two million (2 × 10^6) harvested cells in 400 μL PBS on ice. Lysis can be achieved by homogenization (10-20 passes in a Dounce homogenizer on ice) or by sonication (preferably performed in an ice-water bath). The degree of cell lysis can be checked under a microscope. Centrifuge the homogenate at 14,000 g for 10 min and transfer the clear supernatant into a clean tube. It is advisable to run a pilot test of the sample at different dilutions and select a dilution with readings in the linear range of the standard curve for further assays. Most samples can be stored at -80°C if not assayed immediately.
- If a lysis buffer is to be used, it is recommended to first run an assay to test if components in the lysis buffer interfere with the assay. This can be accomplished by running two standard curves: one prepared in H2O and one prepared in the same proportion of lysis buffer that the sample will contain. If the two standard curves are the same, there is no interference and it is safe to use the lysis buffer. If there is a difference in the standard curves, the lysis buffer may still be used if the standard curve remains linear; however, the standard curve to be used for analyzing the lysate samples will need to be prepared in the lysis buffer.
MAK434
Acetaldehyde Assay Kit
Sufficient for 100 colorimetric tests
Scegli un formato
Scegli un formato
About This Item
Prodotti consigliati
Livello qualitativo
input
cell culture medium
tissue
serum
urine
food(s)
beverage(s)
plasma
applicazioni
agriculture
cosmetics
environmental
food and beverages
Metodo di rivelazione
colorimetric
Malattie correlate
gastrointestinal diseases
Temperatura di conservazione
−20°C
Descrizione generale
Applicazioni
- Alcohol Metabolism Research
- Hepatology Research
- Neurological Research
Caratteristiche e vantaggi
- Simplified Process: Enjoy a hassle-free procedure that requires the addition of a single working reagent and only a 30 minute assay room temperature reaction, saving you time and effort.
- Convenient and Sensitive: Uses only 20 µL of sample for the determination of acetaldehyde with a detection range of 2 µM to 2mM.
- High-Throughput Compatibility: Seamlessly integrate our kit into high-throughput handling systems, ensuring efficiency and accuracy.
Compatibilità
Principio
Altre note
Avvertenze
Warning
Indicazioni di pericolo
Consigli di prudenza
Classi di pericolo
Eye Irrit. 2 - Skin Irrit. 2
Codice della classe di stoccaggio
12 - Non Combustible Liquids
Scegli una delle versioni più recenti:
Certificati d'analisi (COA)
Non trovi la versione di tuo interesse?
Se hai bisogno di una versione specifica, puoi cercare il certificato tramite il numero di lotto.
Possiedi già questo prodotto?
I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.
-
How should MAK434 be used for cell samples?
1 risposta-
Utile?
-
Filtri attivi
Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..