The protocol below has not been tested but is based on adaptations of the reagents to similar instruments.
In order to perform the assay in a microplate instead of cuvettes, the reagent and sample volumes can be reduced by a factor of 5. Thus, the reagent volume would be 200 microliters; the volume of water or sample would be 20 microliters, and the volume of standard would be 10 microliters. The required volume of the enzyme solution would decrease to 2 microliters, which is difficult to pipette accurately. To deliver the enzyme more accurately, dilute it 5x P5244 using Phosphate Buffer, pH 7.5, as the enzyme diluent and pipette 10 microliters into each well.
AA0100
Ammonia Assay Kit
sufficient for 100 assays
Sinonimo/i:
Ammonia Quantitative Test Kit
Scegli un formato
Scegli un formato
About This Item
Prodotti consigliati
impiego
sufficient for 100 assays
Temperatura di conservazione
2-8°C
Applicazioni
Solo come componenti del kit
- Ammonia Assay Reagent 10 vial(s)
- L-Glutamate Dehydrogenase for Ammonia Assay 1 mL/vial
- Ammonia Standard Solution 1 mL/vial
Avvertenze
Danger
Indicazioni di pericolo
Consigli di prudenza
Classi di pericolo
Eye Irrit. 2 - Resp. Sens. 1
Codice della classe di stoccaggio
10 - Combustible liquids
Punto d’infiammabilità (°F)
Not applicable
Punto d’infiammabilità (°C)
Not applicable
Scegli una delle versioni più recenti:
Certificati d'analisi (COA)
Non trovi la versione di tuo interesse?
Se hai bisogno di una versione specifica, puoi cercare il certificato tramite il numero di lotto.
Possiedi già questo prodotto?
I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.
I clienti hanno visto anche
Articoli
Sigma article discusses tumor cell metabolic pathways, focusing on aerobic glycolysis and mitochondrial activity.
Fatty acid synthesis supports cancer cell proliferation, essential for membrane generation, protein modification, and bioenergetics.
-
Can we use this kit for microplate reader system
1 risposta-
Utile?
-
-
How is shipping temperature determined? And how is it related to the product storage temperature?
1 risposta-
Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf
Utile?
-
-
How can I determine the shelf life / expiration / retest date of this product?
1 risposta-
If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdfUtile?
-
-
In the case of bacterial culture supernatant (BHI broth), should the decolorization process be performed? How?
1 risposta-
Any sample solution that is strongly colored and/or has a low ammonia concentration should be decolorized when using this kit. Colored sample solutions often are treated with decolorizing carbon (activated charcoal) to remove color-contributing impurities.
Utile?
-
-
Is there a control that can be used to assess the accuracy of Product AA0100, Ammonia Assay Kit?
1 risposta-
A convenient control for use with this kit is the Ammonia Standard Solution that is provided in the kit.
Utile?
-
-
How can I assess the absorbance change of my reagent blank when using Product AA0100, Ammonia Assay Kit?
1 risposta-
Generally, an absorbance change of 0.050 or less indicates an acceptable range for the reagent blank. An absorbance change higher than this indicates possible contamination of the reagent (or glassware) with ammonia.
Utile?
-
-
Which samples should be deproteinized for use with Product AA0100, Ammonia Assay Kit?
1 risposta-
The basis for this kit was a Diagnostic procedure for the determination of Ammonia in human plasma, whose total protein concentration is approximately 63 to 83 mg/mL. Thus, any solution whose protein concentration is less than approximately 83 mg/mL should not require deproteinization.
Utile?
-
-
What is the Department of Transportation shipping information for this product?
1 risposta-
Transportation information can be found in Section 14 of the product's (M)SDS.To access the shipping information for this material, use the link on the product detail page for the product.
Utile?
-
Filtri attivi
Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..
Contatta l'Assistenza Tecnica.